• 제목/요약/키워드: Photoelastic Fringe

검색결과 76건 처리시간 0.029초

정적 및 동적 하중을 받는 두 상이한 등방성 이종재료의 이종재료상수에 대한 연구 (A Study on the Bimaterial Constant of Two Dissimillar Isotropic Bimaterial Under Static and Dynamic Load)

  • 신동철;황재석
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1776-1785
    • /
    • 2004
  • In this research, the relationships between static bimaterial constant and dynamic oscillation index are studied. It was certified that static bimaterial constant has the same form equation as the dynamic oscillation index. Bimaterial constant and oscillation index are increased with the increment of Young's modulus ratio and approached to the some value. Isochromatic fringe patterns are slanted to the left side with increment of bimaterial constants and oscillation index. Though patterns of stress components in above the crack surface are similar to each other, their magnitudes are different a little. In the ahead of crack tip, there are big differences in the isochromatic fringe patterns and their magnitudes. The influence of bimaterial with Young's modulus ratio is bigger in the propagation crack than in the stationary crack.

Fillet Welding Joint의 파괴기구(破壞機構)와 강도(强度)에 관한 연구(硏究) (Study on Deformation and Strength of Fillet Welds)

  • 엄동석
    • 대한조선학회지
    • /
    • 제7권2호
    • /
    • pp.27-40
    • /
    • 1970
  • The distribution of stress and strain in elastic stages is investigated by the experiments of two dimensional photoelastic coating and Moire fringe method. Center block type and cover plate type of fillet welds are used as specimens in the test. The results are as follows. 1) Center block type gets less uniform stress distribution than cover plate type. And its stress concentration factor, especially at root, is larger than that at toe. 2) When main plate and cover plate closely contact and it cause friction, stress concentration decreases more than that in case of slit. That is because stress can be transmitted on the contact surface. 3) When slit is made, the outside of fillet gets more stress than the inside of it. 4) While the plastic strain distribution of center block type reaches the maximum at root and differs very slightly from that under lower loading, the plastic strain distribution of cover plate type is inclined to get the maximum at the outside of fillet rather than at root. 5) When the plastic strain value of cover plate type is compared with that of center block type at toe and root, the relations between the former and the latter shows root<toe and root>toe. 6) Because stress distribution becomes changed according to loading, fracture angle cannot be estimated by the peaks of elastic stress distribution. 7) The strain distribution just before fracture can be found by Moire fringe method.

  • PDF

TRANSPALATAL LINGUAL ARCH에 의한 골내 응력 분포에 관한 광탄성적 연구 (A PHOTOELASTIC STUDY OF THE STRESS DISTRIBUTION IN BONE BY THE TRANSPALATAL LINGUAL ARCH)

  • 고기영;태기출;국윤아;김상철
    • 대한치과교정학회지
    • /
    • 제27권5호
    • /
    • pp.711-721
    • /
    • 1997
  • 본 연구는 TMA wire로 제작된 transpalatal lingual arch에 의한 골내 응력 분포를 파악하기 위하여 양측성 및 편측성 확장을 가하여 이때 발생하는 치아주위조직 응력 분포 양상을 광탄성 응력 해석법으로 관찰하여 다음과 같은 결과를 얻었다. 1. 양측성 확장시 수평 변형만 적용했을 때 탄선끝이 각진 경우 둥근 탄선끝을 적용한 경우보다 응력이 치근단으로 집중되며 회전 중심을 의미하는 흑색선이 변화하는 양태를 보였고 수직변형량이 증가되면서 전체적인 응력차수의 증가와 흑색선의 하방 이동 양상을 보였다. 2. 편측성 확장을 위해 수평 변형과 함께 확장측에만 수직 변형을 적용하였을 때 확장력이 확장측으로 편중되는 응력 분포를 관찰할수 있었다. 수직 변형량의 증가시 확장측 구치는 정출하는 응력을 보였고 수평변형량의 증가시 고정측 치아도 경사지려는 응력 분포가 관찰되었다. 3. 편측 구치의 회전을 개선하기 위해 철사끝을 비대칭적으로 toe-in한 경우 변형량이 적은 구치의 치근단 원심측에 응력 분포를 관찰할수 있었다. 4. 악궁 확장시 철사의 길이를 줄일수록 무늬차수가 증가하는 응력 분포를 보였다.

  • PDF

하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향 (EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS)

  • 김진열;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH)

  • 정회열;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

헤드기어를 이용한 상악 제1대구치의 후방이동 시 응력분포에 관한 광탄성법적 연구 (A photoelastic evaluation of stress distribution during distal movement of upper molar)

  • 송세은;임성훈;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제34권2호
    • /
    • pp.121-129
    • /
    • 2004
  • 이 연구의 목적은 세 가지 형태의 헤드기어를 이용하여 상악 제1대구치의 후방이동 시 치아 주위 조직에 나타나는 응력분포를 광탄성법을 이용하여 관찰하는 것이다. 광탄성 상악모형에 장착한 헤드기어에 high-pull, straight-pull, cervical-pull의 세 가지 방향에서, face bow의 inner bow와 outer bow를 평행하게 한 상태에서 outer bow의 길이를 세 가지로 다르게 하여 적용시킨 다음 원편광기를 이용하여 응력분포를 분석하였다. 사진기를 이용하여 응력분포를 기록하고, 등색선상의 무늬차수를 이용, 응력분포를 분석하여 이차원적인 광탄성 응력분석을 시행하였다. 그 결과는 다음과 같다. 1. high-pull 헤드기어의 경우, 중간 길이의 outer bow일 때 치체이동에 유리한 응력 분포가 나타났다 2. straight-pull 헤드기어의 경우, 긴 길이의 outer bow일 때 좀더 치체이동에 유리한 응력 분포가 나타났으나, outer bow의 길이에 따른 응력분포의 변화는 적었다. 3. cervical-pull 헤드기어의 경우, 긴 길이의 outer bow일 때 치체이동에 유리한 응력 분포가 나타났다. 임상에서 헤드기어를 이용하여 상악 제1대구치를 후방으로 치체이동시키기 위해서는 facebow outer bow의 높이를 조정하지 않는 경우에는 high-pull 헤드기어에서는 outer bow와 inner bow를 같은 길이로, straight-pull 및 cervical-pull 헤드기어에서는 outer bow를 더 길게 하여 사용하는 것이 추천된다.

테프론 균열 주형법 開發에 관한 硏究 (A study on the Teflon crack Molding Method)

  • 최상인;최선호;황재석
    • 대한기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.945-952
    • /
    • 1987
  • 본 연구에서는 이런 점을 감안하여 테프론 주형법의 장점들을 이용하되 에폭 시 덩이를 만드는 주형상자 대신에 에폭시 판과 테프론 균열이 수직성과 직선성을 유 지할 수 있도록 새로 주형대(molding table)를 개발하여 필요한 균열길이와 두께의 에 폭시판을 만들고 기계가공없이 직접시편으로 사용하여 광탄성장치에서 무늬사진을 얻 음으로서 기계 가공시에 일어나는 여러 문제들을 일소하고 시간과 경비를 크게 절약 하려고 하였으며 지금까지의 어떤 실험방법 보다도 정밀한 측정으로 응력확대계수 해 석상의 오차를 줄이는데 목적이 있다.

화상처리기법을 이용한 변형율해석에 관한 연구 (제1보 마이크로 컴퓨터를 이용한 화상처리기법의 개발) (A Study on the Strain Analysis by Image Processing Technique (part 1: Development of Image Processing Technique with Microcomputer))

  • 백인환;신문교
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.43-56
    • /
    • 1988
  • The image processing system consisted of the microcomputer IBM PC-XT and the graphic board (16 gray level and $640{\times}400$ pixels resolution) has been proposed, and the image processing softwares programmed in the BASIC and in the assembler language have been developed. The programs are consisted of the main menu and the sub menu, that have contained the subroutine for the capture for image data, the determination of region, the histogram, the change of value, the montage, the skeleton, the mask, the moving, the zoom, the disk access and the print. For the application, the photoelastic fringe data have been captured and analyzed. It was seen that the programs are available for the image processing.

  • PDF

광탄성 응력측정을 위한 투과형 원형편광기 제작 및 시험 (Construction and Calibration Test of a Transmission-type Circular Polariscope for Photoelastic Stress Measurement)

  • 백태현;고승기;나의균;김장섭;차병석;조성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.437-441
    • /
    • 2001
  • This paper describes the construction of a circular polariscope. Generally, a circular polariscope contains four optical elements and a light source. The first element following the light source is called the polarizer. It converts the ordinary light into plane-polarized light. The second element is a quarter wave plate which converts the plane-polarized light into circularly polarized light. Following the quarter wave plate, a specimen made of transparent photoelastic material is located in a loading device. The second quarter wave plate is set and the last element is the analyzer. These polarizing elements, two quarter wave plates and two polarizing filters, were purchased from the USA. Frames and other structures for holding polarizing filters were machined and assembled to be rotated. Light box, which include four incandescent lamps and two sodium-vapor lamps, was made. In order to proof the function of the newly built polariscope, Tardy compensation test was applied to a rectangular shaped specimen made of poly-carbonate material (PSM1). The error of the fringe constant, which was measured by the newly built polariscope, was within 4.4 percent compared to the standard value of this material. It is possible to make a good quality of polariscope if accurate polarizing filters will be used.

  • PDF

인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구 (A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES)

  • 정형곤;정문규;이호용
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF