• Title/Summary/Keyword: Photo sensor

Search Result 344, Processing Time 0.025 seconds

Photolithographic Formation of GOD Immobilized Membranes for ISFET Glucose Sensors (ISFET 포도당센서를 위한 GOD 고정화막의 사진식각 형성법)

  • 김창수;최성문;서화일;김의락;손병기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.58-63
    • /
    • 1992
  • Photolithography techniques were applied for immobilization of GOD membrane on the pH-ISFET with photo-sensitive polymers to realize ISEFT glucose sensor. This IC technology-compatible glucose sensor showed good sensing characteristics in the wide range of 10-1000 mg/dl glucose concentrations.

  • PDF

Development of Wrist Type Ubiquitous Optical Sensor (손목형 유비쿼터스 광센서의 개발)

  • Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.129-132
    • /
    • 2008
  • 손목에 착용하여 맥파와 산소포화도 등의 정보를 측정할 수 있는 유비쿼터스 광센서를 개발하였다. 유비쿼터스 광센서의 SNR의 향상을 위해 660nm의 LD와 904nm의 LD를 사용하였으며, 2종류의 LD는 각각 PD를 중심으로 $120^{\circ}$로 배치하였다. 또한 정확한 신호의 측정 및 분석을 위해 LabVIEW를 사용하였다. 제작된 광센서는 정확한 맥박 및 산소포화도의 측정이 가능하였으며 Beer-Lambert 곡선과 부합하여, 구성 및 설계가 정확함을 알 수 있다.

  • PDF

A $32{\times}33$ Photo-elements MOS Image Sensor

  • Park, Sang-Sik;Park, Jeong-Ok;Lee, Jong-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.411-415
    • /
    • 1987
  • A $32{\times}33$ MOS-type area image sensor has been fabricated. The blooming current is reduced to 1/14 by forming +p photocell in P-well instead of a simple p-type substrate. A shallow n+ junction is made to improve the sensitivity of photodiode on short wavelength. Bootstrapping circuit technique is applied to obtain high speed dynamic shift register. The shift register operates at up to 10MHz for 7V clock.

  • PDF

Easy Detection of Amyloid β-Protein Using Photo-Sensitive Field Effect

  • Kim, Kwan-Soo;Ju, Jong-Il;Song, Ki-Bong
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.339-344
    • /
    • 2012
  • This article describes a novel method for the detection of amyloid-${\beta}$($A{\beta}$) peptide that utilizes a photo-sensitive field-effect transistor (p-FET). According to a recent study, $A{\beta}$ protein has been known to play a central role in the pathogenesis of Alzheimer's disease (AD). Accordingly, we investigated the variation of photo current generated from p-FET with and without intracellular magnetic beads conjugated with $A{\beta}$ peptides, which are placed on the p-FET sensing areas. The decrease of photo current was observed due to the presence of the magnetic beads on the channel region. Moreover, a similar characteristic was shown when the Raw 264 cells take in magnetic beads treated with $A{\beta}$ peptide. This means that it is possible to simply detect a certain protein using magnetic beads and a p-FET device. Therefore, in this paper, we suggest that our method could detect tiny amounts of $A{\beta}$ for early diagnosis of AD using the p-FET devices.

Geometric error assessment system for linear guideway using laser-photodiodes (레이저-수광소자를 이용한 선형 이송측의 기하학적 오차측정 시스템)

  • Pahk, H.J.;Chu, C.N.;Hwang, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.180-188
    • /
    • 1994
  • Error assessment and evaluation for machine for machine tool slides have been considered as essential tools for improving accuracy. In this paper, a computer aided measurement technique is proposed using photo pin diodes of quadrant type and laser source. In thedeveloped system, three photo diodes are mounted on a sensor mounting table, and the sensored signal is processed by specially designed signal conditioner to give fine resolution with minimum noise. A micro computer inputs the processed signal, and the geometric errors of five degree of freedoms are successfully evaluated. Pitch, roll, yaw, vertical and horizontal straightness errors are thus assessed simultaneously for a machine tool slide. Calibration techniques such as optics calibration, photo diode calibration are proposed and implemented, giving precise calibration for the measurement system. The developed system has been applied to a practical machine tool slide, and has been found as one of efficient and precise technique for machine tool slide.

  • PDF

Performance Improvement of Magnetic Levitation System by CdS Sensor Compensation (CdS센서의 보상에 의한 자기부상 시스템의 성능 개선)

  • 나승유;최윤영;박민상;윤두현;정병두
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1133-1136
    • /
    • 1999
  • A magnetic levitation control system is inherently nonlinear and very unstable. Thus there should be a stabilizing compensator network and a negative feedback path using noncontact photoresistor or ultrasonic sensors for the levitation operation. Since the photo sensor plays a key role in the system, the steady-state error and transient performance of the overall system depend on the characteristics of the sensors. But the sensor itself also suffers from nonlinearity, and the magnitude of sensor input heavily depends on environmental conditions. To improve the output performance, we added a linearizing circuit for the sensor characteristics and a disturbance cancelation circuit to avoid sensitive output due to extraneous interfering light.

  • PDF

A Study on the Microswitch Support Modification (마이크로스위치 서포트 변경에 관한 연구)

  • Choi, Jin-Soo;Lee, Soo-Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.771-778
    • /
    • 2006
  • Before the Flap type GATE is introduced until, the Turnstile type GATE was plentifully used. The Turnstile type GATE is used plentifully from the Seoul metro, Busan Transportation Corporation and Korea Railroad Corporation. From the Turnstile type GATE, the micro switch breakdown is occurred by the contact of the micro switch which perceives a Turnstile rotation and the cam. The breakdown is cause of the passenger inconveniently. In order to prevent the breakdown which is caused by Micro switch contact, Microswitch support used the sensor in Turnstile rotation perception. The sensor which is used in test is Photo Sensor and Reed Sensor two type. The test result Reed Sensor was suitable in underground environment. When using the RF card, RF card processing came to be quick

  • PDF

A Stability Analysis of Fiber-Optic Current Sensor about a Mechanical Deformation Using by Faraday Rotator Class Fiber Sensor Coil (Faraday Rotator Glass 광섬유 센서코일을 이용한 전류센서의 기계적 변형에 대한 안정도 분석)

  • Kim, Kee-Hyuck;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.53-57
    • /
    • 2004
  • The stabilization of fiber-optic current sensor has been achieved by using a broadband light source and a Faraday Rotator Glass fiber sensor coil. The very low Photo-elastic constant of the fiber suppressed output variations within ${\pm}0.4[%]$ when mechanical disturbance was applied to the sensor coil. Noise characteristics, with different light sources, have also been analyzed, which experimentally proved that the wider bandwidth source showed the better noise performance.

  • PDF

LED IT-based System sensor network transceiver module research (LED IT 기반 시스템 센서 네트워크 송수신 모듈 연구)

  • Jang, Tae-Su;Lee, Jun-Myung;Choi, Jung-Won;Kim, Yong-kab
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.11-12
    • /
    • 2012
  • In this paper, efficient visible light communication technology LED (Light Emitting Diode) lighting through the existing infrared sensor used for performance analysis of transmitting and receiving is possible. LED utilizes lighting by changing light into electricity. Lighting features while maintaining the basic principles of flashing LED and PD (Photo Diode) to send and receive communications from LED lighting communication convergence principle be realized simultaneously enabling. Multiple IT applications under the basic structure of LED technology development, and the current was encountered in real life. LED lighting anywhere with wireless communication technology that can, in order to ~ 1m above the initial value by taking advantage of the system H/W and infrared sensors(PD) are widely used in the entire system that can improve the speed of visible light data transmission system is finished. LED module that is used to communicate whether the performance analysis, For forecasting and communication distance on the LED and infrared sensor configuration of the implementation of the research is to study about the possibility of application methods and indicates.

  • PDF

A Design of Single Pixel Photon Counter for Digital X-ray Image Sensor (X-ray 이미지 센서용 싱글 픽셀 포톤 카운터 설계)

  • Baek, Seung-Myun;Kim, Tae-Ho;Kang, Hyung-Geun;Jeon, Sung-Chae;Jin, Seung-Oh;Huh, Young;Ha, Pan-Bong;Park, Mu-Hun;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.322-329
    • /
    • 2007
  • A single pixel photon counting type image sensor which is applicable for medical diagnosis with digitally obtained image and industrial purpose has been designed with $0.18{\mu}m$ triple-well CMOS process. The designed single pixel for readout chip is able to be operated by single supply voltage to simplify digital X-ray image sensor module and a preamplifier which is consist of folded cascode CMOS operational amplifier has been designed to enlarge signal voltage(${\Delta}Vs$), the output voltage of preamplifier. And an externally tunable threshold voltage generator circuit which generates threshold voltage in the readout chip has been newly proposed against the conventional external threshold voltage supply. In addition, A dark current compensation circuit for reducing dark current noise from photo diode is proposed and 15bit LFSR(Linear Feedback Shift Resister) Counter which is able to have high counting frequency and small layout area is designed.