• Title/Summary/Keyword: Phosphorus removal efficiency

Search Result 338, Processing Time 0.034 seconds

Strategy to Recover Rare Earth Elements from a Low Grade Resource via a Chemical Decomposition Method (화학적 분해법을 이용한 난용성 자원으로부터 희토류 회수 특성 연구)

  • Kim, Rina;Cho, Heechan;Jeong, Jinan;Kim, Jihye;Lee, Sugyeong
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.17-24
    • /
    • 2020
  • In this study, rare earth elements (REE) leaching from a refractory REE ore containing goethite as a major gangue mineral was conducted, introducing a two-stage method of chemical decomposition-acid leaching. At the chemical decomposition step, using one of alkaline agent, NaOH, the ore was decomposed, changing NaOH concentration from 20 to 50 wt% at 10% (w/w) of pulp density and the maximum temperature achieved without boiling at each NaOH concentration. With increasing NaOH concentration, light REE (Ce, La and Nd) and iron were concentrated in the solid phase which is the decomposed product, while aluminum (Al) and phosphorus (P) were removed to the liquid phase, and their concentrations in the solid phase were down to 0.96 and 0.17%, respectively. In addition, through XRD analysis, it was found that the crystallinity of goethite was considerably decreased. At the acid leaching step, the product decomposed by 50 wt% NaOH was leached at 3.0 M HCl and 80 ℃ for 3 hr, then the REE leaching efficiency was above 94% (Ce 80%), and the leaching efficiencies of Al and P were decreased to 12 and 0%, respectively. Therefore, in terms of both REE leaching efficiency and impurity removal, those decomposition and leaching conditions were chosen as optimum processing methods of the investigated material. In terms of REE leaching mechanism, because REE and iron leaching efficiencies showed the positive correlation each other, so it can be concluded that decreasing crystallinity of goethite affect the improvement of REE leaching.

Removal Efficiency of Water Pollutants and Malodor of Pig Slurry using Biofiltration System (여재순환장치를 이용한 돈분뇨 슬러리의 오염물질 및 악취제거 효율)

  • Choi, D.Y.;Kwag, J.H.;Jeong, K.H.;Park, K.H.;Huh, M.Y.;Kim, J.H.;Kang, H.S.;Jeon, K.H.;Park, C.H.;Jeong, J.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.3
    • /
    • pp.217-224
    • /
    • 2009
  • The pig slurry is one of important fertilizer source for production of crops in recent years, but it has many controversial points of utilization such as offensive odor, lack of spread equipment and farmland possession, respectively. This study was carried out in order to remove water pollutants and malodor of pig slurry using biofiltration system. The biofiltration system consists of pig slurry separator, mixing shift and attached blade for sawdust or ricehull, air injection nozzle and outlet for pig slurry and sawdust or ricehull. The characteristics pH, $BOD_5$ (Biochemical Oxygen Demand), $COD_{Mn}$ (Chemical Oxygen Demand), SS (Suspended Solid), T-N (Total Nitrogen), T-P (Total Phosphorus) of the untreated pig slurry used in this study were 7.2, 34,450, 24,604, 71,000, 4,194, $1,631\;ml/{\ell}$, respectively. The $NH_3$ (Ammonia) and $H_2S$(Hydrogen Sulfide) concentration were 70.0, 9.6 ppm, respectively. The initial total microorganisms of pig slurry were $5.0{\times}10^3\;cfu/ml$, and Salmonella, Bacillus were $5.8{\times}10^2$, $1.1{\times}10^3\;cfu/ml$, respectively. The filtration system was very effective on removal of water pollutants of pig slurry. The removal efficiency of the offensive odor of ammonia and hydrogen sulfide in sawdust was higher than those of ricehull. The total microorganisms and bacillus of pig slurry are on the increase by sawdust and ricehull, but Salmonella showed a tendency to decrease in number after that time. Accordingly, the filtration system was very effective to produce a good quality pig slurry.

  • PDF

Evaluation of Treatment Efficiencies of Pollutants under Different Pollutant Fractions in Activated Sludge-Constructed Wetland System for Treating Piggery Wastewater (활성슬러지-인공습지 공법에 의한 돈사폐수처리시스템에서 오염물질의 분획별 정화효율 평가)

  • Kim, Seong-Heon;Seo, Dong-Cheol;Park, Jong-Hwan;Lee, Choong-Heon;Choi, Jeong-Ho;Kim, Hong-Chul;Ha, Yeong-Rae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.4
    • /
    • pp.344-350
    • /
    • 2012
  • BACKGROUND: To design and develop a constructed wetland for effective livestock wastewater treatment, it is necessary to understand the removal mechanisms of various types of pollutants in constructed wetlands. The objective of this study was to evaluate the treatment efficiency of pollutants under different types of fraction in constructed wetland system for treating piggery wastewater. METHODS AND RESULTS: The piggery wastewater treatment plant that consisted of activated sludge tank, aerobic and anaerobic beds was constructed. The concentration of COD(Chemical oxygen demand) in effluent by fraction was 71.5 mg/L for soluble COD, 142 mg/L insoluble COD. The concentration of SS(Suspended solid) in effluent by existing form was 102 mg/L for volatile SS, 15.5 mg/L for fixed SS. The concentration of T-N(Total nitrogen) and T-P(Total phosphorus) in effluent by existing form were 12.8 mg/L and 3.05 mg/L for dissolved form, 35.0 mg/L and 1.93 mg/L for suspended form. The removal efficiencies of COD, SS, T-N and T-P in hot season(summer and autumn) were higher than those in cold season(spring and winter). The removal efficiencies of COD, SS, T-N and T-P in effluent were 98.0, 99.0, 98.2 and 99.2% for all seasons, respectively. CONCLUSION(S): The results indicated that removal types of pollutants were insoluble COD(ICOD), volatile SS(VSS), dissolved T-N(DTN) and dissolved T-P(DTP) in constructed wetlands for treating piggery wastewater.

Adsorption Characteristics of Cadmium ions from Aqueous Solution using by-product of Brewing (주정오니를 활용한 수중의 카드뮴(Cd) 흡착 특성)

  • Kim, Min-Su;Ham, Kwang-Joon;Ok, Yong-Sik;Gang, Seon-Hong
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.152-158
    • /
    • 2010
  • Biosorption is considered to be an alternative method to replace the present adsorbent systems for the treatment of metal contaminated wastewater. In this study, by-product which was abandoned from brewing factory was used to remove metal component in aqueous solution. The experimental results showed that the range of the removal efficiency is 60~91% and adsorption equilibrium was reached in about 3 hr. FT-IR and stereo microscope has been used to observe the surface conditions and changes in functional groups by calcination. At the end of elution, the amount of nitrogen and phosphorus in water was increased 11 and 7 times compare raw sample to calcinated samples. The Langmuir isotherm adequately described the adsorption of waste materials and the maximum adsorption capacity was 28.17 mg/g for Cd. The overall results suggested that waste material might can be used for biosorption of Cd.

The improvement of the operating process of sewage treatment plants in the upstream area of dam by MASS FLOWmodelling (MASS FLOW 모델링을 통한 댐상류지역의 공공하수처리시설 공정개선방안)

  • Lee, Hyunseop;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.130-138
    • /
    • 2020
  • As of 2017, the sewerage penetration rate of Seoul and metropolitan cities is more than 90%, and the number of domestic sewage treatment plants increased by 25% from 3,064 in 2010 to 4,072 in 2017. Among them, sewage treatment plant operated by SBR system is 585, which is 17% higher than 2010. In order to improve the water quality of the water source and improve the operation of the small sewage facilities, the improvement of the process was studied by applying the modelling to 49 facilities of the sewage treatment plant in Andong Imha dam area with more than 500㎥/day 3 places and 46 places less than 500㎥/day. As an improvement plan for modelling, candidate data were derived by reviewing operation data for 5 years. 49 facilities are operated by 12 types of operating processes. Among them, 1 place mort than 500㎥/day with SBR method and 9 facilities with less than 500㎥/day were selected by dividing 46 sites into 3 types. As a result of applying modelling to more than 500㎥/day, it was possible to improve the quality of discharged water through SRT control and it was found that applying model to sites of small scale treatment plants can improve the removal efficiency of TP by up to 14.4%. As a result, the data of this study could be used to improve and improve the operation of sewage treatment plants and RCSTP(Rural Community Sewage Tratment Plant).

Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant (바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구)

  • Shin, Jae-Suk;Kim, Sung-Chul;Cho, Kwang-Ju;Choi, Choong-Ho;Choi, In-Wook;Park, Jeong-Ja;Park, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.115-121
    • /
    • 2009
  • The hybrid constructed wetland(HCW) as tertiary treatment process of a bio industrial wastewater treatment plant was employed to estimate applications for the reuse of final effluent. Raw wastewater was sequently treated through chemical and biological treatment processes and the biologically treated water was flowed into the HCW. The HCW system was composed of two constructed wetlands connected in series; The one is the aerobic constructed wetland with natural air draft system whose driving force for air supply was the difference between the temperature of the air inside the wetland and the ambient air, and the other is the anaerobic/anoxic constructed wetland. Average influent concentrations of BOD, SS, T-N and T-P in the HCW were 53mg/L, 48mg/L, 34mg/L and 3mg/L, respectively. After being treated at HCW, final effluent concentrations of BOD, SS, T-N and T-P were 2.3mg/L, 1.2mg/L, 7.95mg/L and 0.83mg/L, respectively. Referring to a reuse standard for a sewage wastewater, final effluent could sufficiently be reuse as landscaping, washing or agriculture water. HCW system with the aerobic/anaerobic combined constructed wetland could be achieved a high removal efficiency because each constructed wetland was functionalized to be removed efficiently organics, nitrogen and phosphorus. HCW system could be estimated to be successful application as tertiary treatment process of a various industrial and municipal wastewater.

  • PDF

Change of dry matter and nutrients contents in plant bodies of LID and roadside (도로변 및 LID 시설 내 식생종류별 식물체 내 건물률 및 영양염류 함량 변화)

  • Lee, YooKyung;Choi, Hyeseon;Jeon, Minsu;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.35-43
    • /
    • 2021
  • The application of nature-based solutions, such as low impact development (LID) techniques and green infrastructures, for stormwater management continue to increase in urban areas. Plants are usually utilized in LID facilities to improve their pollutant removal efficiency through phytoremediation. Plants can also reduce maintenance costs and frequency by means of reducing the accumulation of pollutants inside the facility. Plants have long been used in different LID facilities; however, proper plant-selection should be considered since different species tend to exhibit varying pollutant uptake capabilities. This study was conducted to investigate the pollutant uptake capabilities of plants by comparing the dry matter and nutrient contents of different plant species in roadsides, LID facilities, and landscape areas. The dry matter content of the seven herbaceous plants, shrubs, and arboreal trees ranged from 60% to 90%. In terms of nutrient content, the total nitrogen (TN) concentration in the tissues of herbaceous plants continued to increase until the summer season, but gradually decreased in the succeeding periods. TN concentrations in shrubs and trees were observed to be high from early spring up to the late summer seasons. All plant samples collected from the LID facility exhibited high TP content, indicating that the vegetative components of LID systems are efficient in removing phosphorus. Overall, the nutrient content of different plant species was found to be highly influenced by the urban environment which affected the stormwater runoff quality. The results of this study can be beneficial for establishing plant selection criteria for LID facilities.

The Effect of Algae on Coagulation and Filteration of Water Treatment Process (정수처리과정중 응집및 여과에 미치는 조류의 영향)

  • Lim, Young-Sung;Song, Won-Seb;Cho, Ju-Sik;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • Seasonal variations of dominant algae species and the effects of these algae on coagulation and filteration of water treatment were investigated at Chilseo water treatment plant in downstream of Nakdong river from January in 1995 to Desember of 1998. The water quality of Nakdong river was found to be a hyper eutrophic state during the investigation periods. In the measurement, Chlorophyll-a contents ranged $20.7{\sim}180.9{\mu}g/l$ and total nitrogen contents(T-N) and total phosphorus contents(T-P) exceeded more than 3.4mg/l and 0.1mg/l, respectively. The changes in dominant algae species was in the order of Stepanodiscus sp., Asterionella sp., Melosira sp., Microcystis sp. and Synedra sp. from spring to winter. Microcystis sp. especially, was blooming during summer and Synedra sp. and Stepanodiscus sp. during winter. Although most diatomous algae appeared in the water treatment process caused filter clogging and reduced efficiency of coagulation and sedimentation, Synedra sp. and Stepanodiscus sp were revealed as the main trouble algae. Malfunction of water treatment process caused by Synedra sp. and Stepanodiscus sp. started at the algae concentrations of 800cells/ml and 1,820cells/ml, respectively. When chlorophyll-a content was $18.9{\mu}g/l$, the optimum amounts of coagulant were found to be 40mg/l of Alum and 16mg/l of PACS. Under condition of chlorophyll-a content of $154.1{\mu}g/l$, addition of Alum at the level of 75mg/l and PACS at the level of 35mg/l showed the lowest turibidity. The result indicates that increased amounts of the coagulants should be added for a better water treatment as chlorophyll-a contents increased. Addition of Alum at the amount of 60mg/l and 30mg/l of PACS removed Stepanodiscus sp. algae at the rate of 85% and 83%, respectively. In case of Synedra sp., 50mg/l of Alum and 25mg/l of PACS showed removal rates of 79% and 81%, respectively. Synedra sp. algae at the standing crops of 1,500cells/ml started filter clogging and a filtering process was completely inhibited after 8 hours. At this situation the filter clogging by Synedra sp. algae occurred at the depth of 5cm from the top anthracite layer. On the other, other algae did filter clogging at the depth of 10cm.

  • PDF