• 제목/요약/키워드: Phenol matrix

검색결과 30건 처리시간 0.027초

Glass/phenol 복합적층판의 저속충격 특성 (Low Velocity Impact Characteristics of Glass/phenol Composite Laminates)

  • 김재훈;김후식;박병준;안병욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.228-233
    • /
    • 2001
  • It is well known that composite laminates are easily damaged by low velocity impact. The damage of composite laminates subjected to impact loading are occurred matrix cracking, delamination, and fiber breakage. The damage of matrix cracking and delamination are reduced suddenly the compressive strength after impact. This study is to evaluate impact characteristics and the relationship between impact force and inside damage of composite laminates by low velocity impact loading. UT C-scan is used to determine impact damage areas by impact loading.

  • PDF

S-2 유리섬유 평직복합재의 기지재료 및 스티칭에 따른 충격 특성 비교 (Impact Property of S-2 Glass Woven Composites with Different Matrices and Stitching)

  • 변준형;황병선;엄문광;이정훈;남원상;송승욱;이창훈
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.31-34
    • /
    • 2005
  • For the damage tolerance improvement of conventional laminated composites, stitching process has been utilized for providing through-thickness reinforcements. 2D prefonl1S were stacked with S-2 glass plain weave, and 3D preforms were fabricated using the stitching process. For the matrix system, epoxy and phenol resins were considered. To examine the damage resistance performance the low velocity drop weight impact test has been carried out, and the impact damage was examined by scanning image. CAI (Compressive After Ih1paet) tests were also conducted to evaluate residual compressive strength. Compared with 2D epoxy composites, 2D phenol composites showed drastic reduction in the compressive strength prior to impact because of the higher contents of voids. The damage area of 2D phenol composites were also larger than that of 2D epoxy composites. However, by introducing the stitching, the damage area of 3D phenol composites was reduced by 60%, while the CAI strength improvement was negligible.

  • PDF

난연.기능성 복합성형체 제조 및 특성

  • 현병민;강영구
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 춘계 학술논문발표회 논문집
    • /
    • pp.457-460
    • /
    • 2002
  • 현재 건축단열재, 흡음재, 바닥재로 사용되는 panel 성형, 제작하기 위해 다종의 유기고분자 matrix가 사용되고 있으며 polyurethane, vinyl acetate, urea-formaldehyde resin 또는 melamine-formaldehyde, phenol-form aldehyde resin 등을 사용하고 있으나 이러한 고분자 matrix를 사용한 건축용 panel의 경우 화재시 유독 gas와 더불어 급격한 화재전파의 매개체로 사용될 수 있어 난연제 첨가로 이러한 현상을 억제하고 있다.(중략)

  • PDF

The Solid Phase Extraction of Phenol and Chlorophenols by the Chemically Modified Polymeric Adsorbents with Porphyrins

  • Jung, Min-Woo;Kim, Ki-Pal;Cho, Byung-Yun;Paeng, Insook R.;Lee, Dai-Woon;Park, Young-Hun;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권1호
    • /
    • pp.77-81
    • /
    • 2006
  • The commercially available Amberlite XAD-2 and XAD-4 resins were modified with macrocyclic protoporphyrin IX (PPIX) or tetrakis(p-carboxyphenyl) porphyrin (TCPP) to enhance the adsorption capacity for phenol and chlorophenols. The chemically modified polymeric adsorbents (XAD-2+PPIX, XAD-2+TCPP, XAD-4+PPIX, and XAD-4+TCPP) were applied to the solid phase extraction as an adsorbent material for the preconcentration of phenol and chlorophenols in environmental waters. Generally, the synthesized adsorbents showed higher recoveries than underivatized adsorbents, XAD-2 and XAD-4, without matrix interferences. Especially, XAD-4+PPIX showed more than 90% recoveries for all compounds used in this study including hydrophilic phenol. The major factor for the increase of the adsorption capacity was the increase of $\pi$-$\pi$ interaction between adsorbents and samples due to the introduction of the porphyrin molecule. However, the breakthrough volumes and recovery values of the XADs+TCPP columns were slightly decreased for the bulky chlorophenols such as TCP and PCP. Using molecular mechanics methods, the structures of TCPP and PPIX were compared with that of porphine, the parent molecule of porphyrin. Four bulky p-carboxyphenyl groups of TCPP were torsional each other, thus the molecular plane of TCPP were not on the same level. In conclusion, the decrease of breakthrough volumes and recovery values of XADs+TCPP columns for bulky phenols can be explained by the steric hindrance of the $\pi$-$\pi$ interaction between porphyrin plane and the phenols.

저속 충격을 받는 Glass/phenol 복합적층재의 손상 해석 (A Damage Analysis of Glass/phenol Laminated Composite Subjected to Low Velocity Impact)

  • 나재연;이영신;김재훈;조정미;박병준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.89-92
    • /
    • 2002
  • Traditionally unidirectional laminated composite which are characterized by high specific stiffness and strength were used for structural application. But theses composites are highly susceptible to impact damage because of lower transverse tensile strength. The main failure modes of laminated composite are fiber breakage, matrix cracking and delamination for low velocity impact. The modified failure criterions are implemented to predict these failure modes with finite element analysis. Failure behavior of the woven fabric laminated composite which is used in forehead part of subway to lighten weigh has been studied. The new failure criterions are in good agreement with experimental results and can predict the failure behavior of the woven fabric composite plate subjected to low velocity impact more accurately.

  • PDF

난연성 복합적층재의 저속충격특성 (Low velocity Impact Characteristics of Non-flamable Composite Laminates)

  • 김재훈;김후식;조정미;박병준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.179-182
    • /
    • 2001
  • Impacter tester was build of to evaluate the characterization of non-flamable Glass/phenol laminate plates under the low velocity impact. The damage of composite laminates are matrix cracking, delamination, and fiber breakage for impact energy. In this study, this is to find impact properties of Glass/phenol in used in a forehead part of lighting subway. To determine impact damage characteristics which is made in a laminate, use the UT C-scan after- macrography. And then evaluated the reduction of strength in a rate of impact energy with CAI(Compression After Impact) test

  • PDF

열경화성수지 성형재료의 경화 안전성에 관한 연구 (Study on the Curing Safety of Thermosetting Resin Mold Meterial)

  • 최일곤;최재욱;김상렬
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.71-76
    • /
    • 1997
  • In this paper, it was described results of study on curing safety of molding meterial, about the variation of phenol resin contents, wood flour contents and moisture of wood flour, under the same condition. The experimental results are summarized as follows ; 1) When the curing temperature was high, the curing time was short in the case of 4~8wt% moisture of wood flour, but in the case of more than l2wt% moisture of wood flour, the curing time was long. 2) The curing time for curing temperature was more short when 6wt% moisture of wood flour than 4wt% moisture of wood flour. 3) The more wood flour content and moisture of wood flour content, the longer curing time and the more mineral filler content, the shorter curing time. 4) When the phenol resin content of main matrix increase, the curing time was short.

  • PDF

복합적층재의 온도에 의한 저속충격특성 (Effect of Temperature on Low Velocity Impact Characteristics of Composite Laminates)

  • 한영욱;김후식;김재훈;이영신;조정미;박병준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.93-96
    • /
    • 2002
  • Instrumented impact tests and compression-after-impact(CAI) tests have been used to evaluate the effect of temperature on the low-velocity impact characteristics of phenolic matrix composites reinforced with various woven glass fabric. Impact characteristics and damage area in laminates are evaluated by C-scan. It is shown that the extent of damage and residual compressive strength of the laminates vary with energy level and impact test temperature. The damage area increases with increasing impact energy and temperature. All these observations indicate reduced impact damage resistance and damage tolerance of the laminates at elevated temperature.

  • PDF

페놀수지 탄화 코팅법을 이용한 섬유강화 복합재료 계면 형성에 관한 연구 (Novel Phenol Resin Carbonizing Method for Carbon Interlayer Coating between Reinforcing Fiber and Matrix in Fiber Reinforced Ceramic Composite)

  • 김세영;우상국;한인섭
    • 한국세라믹학회지
    • /
    • 제46권3호
    • /
    • pp.301-305
    • /
    • 2009
  • The novel carbon coating process for interlayer of fiber reinforced ceramic composites between fiber and matrix was performed by carbonizing phenolic resin solution that coated on fiber surface in $N_2$ atmosphere at $600^{\circ}C$ to improve the strength and fracture toughness of CMC(ceramic matrix composite). 160 nm carbon layer was coated on fiber surface with 5 vol% of phenolic resin solution. Since the process temperature ($600^{\circ}C$) is lower than chemical vapor deposition($900{\sim}1000^{\circ}C$), the strength and toughness could be preserved. Furthermore the coating thickness uniformity was improved to 8% of deviation along the stacking sequence. Therefore, prevention from fiber degradation during coating process and controlling coating thickness uniformity along the preform depth were achieved by coating with phenolic resin carbonizing method.

경화온도에 따른 Castor Oil/epoxy의 강인성 (The Toughness of Castor Oil Modified Epoxy Resins by Various Cure Temperatures)

  • 김종석;홍석표
    • 공업화학
    • /
    • 제8권6호
    • /
    • pp.973-978
    • /
    • 1997
  • Diglycidyl ether of bisphenol A(DGEBA)수지에 castor oil(CO)로 혼합한 후 경화촉매인 tris(dimethylaminomethyl) phenol (DMP-30)로 반응시킨 에폭시의 강인성과 모폴로지를 관찰하였다. 개질제인 CO와 에폭시수지의 혼합물은 기존의 에폭시 개질제인 carboxyl terminated butadiene acrylonitrile(CTBN)보다 상용성이 좋았다. 경화온도와 CO의 양이 증가할수록 유리전이온도가 감소하였는데, CO/에폭시 경화물은 경화온도가 증가할수록 가교밀도가 감소하면서 연성구조를 갖게 되는 것으로 해석되었다. CO/에폭시 경화물은 경화온도 $40^{\circ}C$에서 CO의 양이 증가함에 따라 강인성이 약간 증가하였다. 경화온도가 증가와 CO의 양이 증가함에 따라 강인성이 증가하였다.

  • PDF