• 제목/요약/키워드: Phast

검색결과 54건 처리시간 0.025초

Integrated Schistosomiasis and Soil-Transmitted Helminthiasis Control over Five Years on Kome Island, Tanzania

  • Kaatano, Godfrey M.;Siza, Julius E.;Mwanga, Joseph R.;Min, Duk-Yong;Yong, Tai-Soon;Chai, Jong-Yil;Ko, Yunsuk;Chang, Su Young;Kullaya, Cyril M.;Rim, Han-Jong;Changalucha, John M.;Eom, Keeseon S.
    • Parasites, Hosts and Diseases
    • /
    • 제53권5호
    • /
    • pp.535-543
    • /
    • 2015
  • Integrated control strategies are important for sustainable control of schistosomiasis and soil-transmitted helminthiasis, despite their challenges for their effective implementation. With the support of Good Neighbors International in collaboration with National Institute of Medical Research, Mwanza, Tanzania, integrated control applying mass drug administration (MDA), health education using PHAST, and improved safe water supply has been implemented on Kome Island over 5 years for controlling schistosomiasis and soil-transmitted helminths (STHs). Baseline surveys for schistosomiasis and STHs was conducted before implementation of any integrated control strategies, followed by 4 cross-sectional follow-up surveys on randomly selected samples of schoolchildren and adults in 10 primary schools and 8 villages, respectively, on Kome islands. Those follow-up surveys were conducted for impact evaluation after introduction of control strategies interventions in the study area. Five rounds of MDA have been implemented from 2009 along with PHAST and improved water supply with pumped wells as other control strategies for complementing MDA. A remarkable steady decline of schistosomiasis and STHs was observed from 2009 to 2012 with significant trends in their prevalence decline, and thereafter infection rate has remained at a low sustainable control. By the third follow-up survey in 2012, Schistosoma mansoni infection prevalence was reduced by 90.5% and hookworm by 93.3% among schoolchildren while in adults the corresponding reduction was 83.2% and 56.9%, respectively. Integrated control strategies have successfully reduced S. mansoni and STH infection status to a lower level. This study further suggests that monitoring and evaluation is a crucial component of any large-scale STH and schistosomiasis intervention.

가상체적을 이용한 폭발위험장소 구분의 타당성 검토 (Validity Review on Classification of Explosion Hazardous Area using Hypothetic Volume)

  • 임지표;정창복
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.68-75
    • /
    • 2014
  • It is very important to classify explosion hazardous area (EHA) suitably and to use proper explosion-proof electric installations for facilities using flammable gases and liquids. In the past, various examples in the Notification of Ministry of Employment and Labor were referred to in classifying EHA. But, at present, many companies use the hypothetical volume in Korean Standards (KS). This study reviews the validity of EHA classification based on the hypothetical volume by comparing the calculated radii of EHA with those obtained by a consequence analysis program called PHAST and a mathematical approach in British Standards (BS). The radii of EHA by the hypothetical volume were found to be slightly larger than those by the other two methods. This was attributed to rather conservative uses of a safety factor(k) and a correction factor(f) for availability of ventilation in calculating the hypothetical volume. Since the differences are not so conspicuous, however, it is concluded that the hypothetical volume in KS is a valid means for the classification of EHA. This study also presents a table of the radii of EHA for easy reference by small-scale companies using city gas, C3-LPG and flammable liquid(toluene), respectively. The table consists of 25 leakage scenarios corresponding to combinations of 5 pipe(nozzle) sizes and 5 operating conditions for each flammable gas and liquid.

BLEVE를 고려한 LPG 시설 Siting 분석 (Analysis of LPG Facility Siting Considering BLEVE)

  • 김태범;이경림;이주희;정승호;이건모
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.26-32
    • /
    • 2016
  • In previous studies on LPG siting in Korea, the scope have not included the probability of the secondary events of adjacent LPG tanks or structures from an explosion source. Therefore, it is essential to first identify the phenomenon which can be caused by BLEVE and then, properly assess their effects to each target including secondary event. In this study, we calculated the effects from a potential BLEVE of 15 ton LPG tank causing damages of storage tanks (LPG), structures and human using Phast ver. 6.7 and then suggested three risk zones (Zone I, II, III) assuming the consequences such as overpressure, heat radiation and missile effect by fragments. Zone I and II are divided at the line of 50% occurrence of the secondary event. Zone II and III are divided by Individual Risk(IR). The zone approach in this study can be used for more effective and safer Land Use Planning (LUP) for the future.

Radiolabelled Monoclonal Antibodies (McAb): An Alternate Approach to the Conventional Methods for the Assessment of Cardiomyocyte Damage in an Experimental Brain-Death Pig Model

  • Haider, Kh.H.;Stimson, W.H.
    • Archives of Pharmacal Research
    • /
    • 제21권5호
    • /
    • pp.496-502
    • /
    • 1998
  • The present study was carried out to determine the possible use of cTn-I in the cardiac myofibrillar architecture, as a potential target for in vivo radioimmunodetection of cardiac damage in a brain death pig model. Radioiodiantion of the anti-cTn-I 5F4 McAb was carried out by lactoperoxidase method. the percentage iodine incorporation achieved was 70-75%. The radioiodinated McAbs were purified on Sephadex G-25 column and characterised by Paper chromatography, Phast Gel electrophoresis and electroimmunoblotting. Radioiodinated anticTn-I 5F4 McAbs were employed alongside Pyrophosphate($Tc_{99m}$-PPi$) and $Thallium^{201}$ chloride($TI^{201}$) in 24 landrace pigs (brain-dead=18 & sham-operated=6). The percentage cardiac uptake of the radiolabelled antibody injected dose was significantly higher in the brain dead animals(0.196%) as compared to that of sham-operated animals (0.11%). Specific in vivo localization of radiolabelled McAbs in the infarcted cardiac tissue was confirmed by computer-aided reconstruction of 3-D images of the isolated heart. The preliminary results of the study revealed preferential uptake of radiolabelled antibody at the site of myocyte damage resulting from artificially induced brain death.

  • PDF

수소가스 누출 시나리오에 따른 피해예측에 관한 연구 (Study on the Consequence Analysis about Leakage Scenarios for Hydrogen Gas)

  • 김태훈;오영달;이만수
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.159-165
    • /
    • 2014
  • For the hydrogen economy system being tried starting with the 21st century, the fields that was not dealt with so far, such as the safety measure for large leakage accidents, the safety problem at infrastructures like a hydrogen station, the safety problem in terms of automobiles depending on introduction of hydrogen cars, the safety problem in a supply for homes like fuel cells, etc., are being deeply reviewed. In order to establish a safety control system, an essential prerequisite in using and commercializing hydrogen gas as an efficient energy source, it is necessary to conduct an analysis, such as analysis of hydrogen accident examples, clarification of physical mechanisms, qualitative and quantitative evaluation of safety, development of accident interception technologies, etc. This study prepared scenarios of hydrogen gas leakage that can happen at hydrogen stations, and predicted damage when hydrogen leaks by using PHAST for this.

냉동, 냉장 시스템에서 NH3 누출 사고 시 장외영향평가를 위한 피해범위 및 대피거리 산정에 관한 연구 (Recommended Evacuation Distance for Offsite Risk Assessment of Ammonia Release Scenarios)

  • 박상욱;정승호
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.156-161
    • /
    • 2016
  • An accident of an ammonia tank pipeline at a storage plant resulted in one death and three injuries in 2014. Many accidents including toxic gas releases and explosions occur in the freezing and refrigerating systems using ammonia. Especially, the consequence can be substantial due to that the large amount of ammonia is usually being used in the refrigeration systems. In this study, offsite consequence analysis has been investigated when ammonia leaks outdoors from large storages. Both flammable and toxic effects are under consideration to calculate the affected area using simulation programs for consequence analysis. ERPG-2 concentration (150 ppm) has been selected to calculate the evacuation distance out of various release scenarios for their dispersions in day or night. For offsite residential, the impact area by flammability is much smaller than that by toxicity. The methodology consists of two steps as followings; 1. Calculation for discharge rates of accidental release scenarios. 2. Dispersion simulation using the discharge rate for different conditions. This proactive prediction for accidental releases of ammonia would help emergency teams act as quick as they can.

반응표면법과 ANOVA 기반의 수소 누출에 대한 유효인자 분석 (Analyzing Effective Factors on Hydrogen Release Based on Response Surface Method and Analysis of Variance)

  • 이준서;오세현;안승효;김은희;마병철
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.712-721
    • /
    • 2023
  • While hydrogen is widely used, it has a low minimum ignition energy, raising safety concerns when using it. This research studied which parameters are the key variables in the hydrogen release and diffusion. These parameters were divided into six process variables in the initial release and two environmental variables in the dispersion. One hundred and twenty cases were selected through design of experiment, and the end-point in each case were analyzed using PHAST. Afterwards, an end-point prediction model was developed using RSM and ANOVA, and the impact of each variable on the endpoint was analyzed. As a result, the influence of eight variables was graded. The nozzle diameter had the greatest influence on the end-point, while the pipe roughness coefficient had no effect on the end-point. It is expected that these results will be used as basic data to improve safety across all fields of hydrogen handling facilities.

수소충전소의 안전성에 관한 연구 (A Study on Safety of Hydrogen Station)

  • 고재욱;이대희;정인희
    • 한국가스학회지
    • /
    • 제13권1호
    • /
    • pp.45-51
    • /
    • 2009
  • 본 논문은 국내에 건설된 충전소를 분석 검토하여 수소충전소에 대한 안전성 평가를 실시함으로써 수소충전 소의 안전성에 대한 확인과 충전소 설치 시 필요한 기준마련에 기초자료를 제공하는 것이 궁극적인 목표이다. 안전성 평가 방법으로 FMEA (Failure Mode and Effect Analysis)를 사용하였고, 충전소를 크게 4개의 공정(제조, 압축, 저장, 충전)으로 분류하였다. 또한 각각의 발견된 위험요소에 S (severity), O (occurrence), D (detection)의 점수를 부여하여 이 세 요소의 곱의 값인 RPN (Risk Priority Number)의 수치를 이용하여 위험의 우선순위를 정하고, 이를 바탕으로 시나리오를 생성하였다. 생성한 시나리오를 기반으로 사고피해영향평가 결과 주요한 사고 유형으로 jet fire와 폭발이 나타났고, PSA (pressure swing adsorption) 공정 feed line에서의 누출의 경우 원료물질에 따라 CO가스의 농도가 상이할 수도 있으나, CO가스중독 위험성을 함께 예측되었다.

  • PDF

항만에서 위험물 운송 중 유해화학물질 누출 위험성에 관한 연구 (Risk Analysis of Transporting Hazardous Substances in Harbor Using Modeling Program)

  • 윤수경;윤자연;한지윤;정승호
    • 한국해양공학회지
    • /
    • 제32권4호
    • /
    • pp.272-278
    • /
    • 2018
  • Recently, the use of hazardous chemicals has been continuously increasing. Therefore, the international trade volume is growing and chemical accidents have increased. Nowadays, the safety awareness of the public has increased. As a result, the management and supervision of hazardous chemicals have been strengthened. However, the port policy of Korea has focused on increasing the volume of cargo through facility development. Thus, the port management of hazardous chemicals has been relatively neglected. For national economic growth and society, the port management of hazardous chemicals should be considered to efficiently ensure safety and economic growth. Therefore, this study assumed scenarios where hazardous materials were moved in a dangerous container, not only on appropriate wharfs but also in ports that were close to a big city. The BTX substances were selected among the toxic chemicals with large import and export volumes, and the risk distance and damage effects were predicted using various risk assessment programs. It is expected that this could be used to improve a port safety management system and could be utilized to determine the safety distance in case of an accident.

LPG 충전소의 BLEVE 현상에 따른 피해효과 분석 (A Study on Damge Effect from Boiling Liquid Expanding Vapor Explosion(BLEVE) of LPG Charging Facility)

  • 노삼규;김태환;함은구
    • 한국가스학회지
    • /
    • 제3권3호
    • /
    • pp.45-50
    • /
    • 1999
  • 도심지내에 위치한 부천 LPG충전소 사고 조사를 통하여 가장 피해효과가 큰 탱크로리 폭발에 따른 결과를 분석하였다. 분석범위는 BLEVE 현상에 의한 방출열과 과압이 충전소주변에 위치한 구조물이나 인체에 미치는 영향을 대상으로, 실제 현장조사를 통하여 수집된 피해결과와 이론적인 모델(PHAST-Process Hazad Analysis Sortware Tools) 분석 결과를 비교하였다. 부천 LPG 충전소 폭발 사고의 피해효과는 방출열의 경우 두 가지 모두 큰 차이를 보이지 않았으나, 과압의 경우, 실제 피해는 이론적 모델분석결과의 약 $15\%$정도에 해당하는 축소된 거리에서 나타났다. 또한, 충전소 인근에 위치한 구조물에 대한 피해효과는 부분적으로 과압에 의한 균열 및 붕괴 현상보다는 열 효과에 의한 콘크리트 강도 저하와 성상변화가 크게 나타났다.

  • PDF