• Title/Summary/Keyword: Phases and patterns

Search Result 315, Processing Time 0.025 seconds

Role of class-C fly Ash in the Development of Strength & Microstructure of Fly Ash-GGBS Geopolymer

  • Sasui, Sasui;Kim, Gyu Yong;Lee, Sang Kyu;Son, Min jae;Hwang, Eui Chul;Nam, Jeong Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.79-80
    • /
    • 2020
  • The class-C fly ash (FA) and ground granulated blast-furnace slag (GGBS) based geopolymer activated in NaOH (4M) was studied regarding compressive strength, porosity, microstructure and formation of crystalline phases. The class-C FA and GGBS blends resulted in reduced strength and increased porosity of the matrix with the increase in FA content. The unreactivity of calcium in blends was observed with increasing FA content leading to strength loss. it is evident from XRD patterns that calcium in FA did not contribute in forming CSH bond, but formation of crystalline calcite was observed. Furthermore, XRD analyses revealed that reduction in FA leads to the reduction in crystallinity and SEM micrographs showed the unreactive FA particles which hinder the formation of denser matrix.

  • PDF

Deposition of Diamond Thin Film Prepared by Hot-filament Chemical Vapor Deposition (Hot-filament법에 의한 Diamond 박막증착)

  • 윤석근;한상목;소명기
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.10
    • /
    • pp.777-784
    • /
    • 1991
  • Diamond films have been growth by the hot-filament chemical vapor deposition (HFCVD) using CH4 and H2 gaseous mixture on the Si substrate. The experimental results indicated that the deposits were pure diamond and contained no amount of non-diamond phases such as amorphous carbon or graphite. The diamond films were deposited well at the conditions: the filament temperature of 210$0^{\circ}C$, the substrate temperature of 77$0^{\circ}C$, the CH4 concentration of 1.76%, the reactor pressure of 30 torr, and the deposition time of 7 hr. At this growth condition, the maximum deposition rate was 2 ${\mu}{\textrm}{m}$/hr. X-ray diffraction patterns and texture coefficient results showed that preferred orientation of the diamond films was {111} orientation under all experimental conditions.

  • PDF

PZTN Sintered at the Low Temperature by the Glass Phase Transient Processing (글래스 천이 공정에 의해 저온소결된 PZTN)

  • Kim Chan Young
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.97-102
    • /
    • 2005
  • This research was a fundamental study for the low temperature sintering of PZTN by glass phase transient processing. To lower the sintering temperature, the glass phase Processing was used. Also to improve the electrical properties, the transient processing was utilized. After characterization, the various analytic techniques, such as Archimedes method for the measuring densification, x-ray diffraction patterns for the quantitative analysis of crystalline phases were utilized. Also the dielectric constant, dissipation factor, and piezoelectric coefficients were measured to evaluate the PZTN sintered at the $950^{\circ}C$ and $1050^{\circ}C$. This was confirmed that the sintering temperature of PZTN was reduced by $950^{\circ}C$ and the electrical properties were improved by the transition processing. Therefore, the glass phase transient processing can be applicable to low the sintering temperature with the dielectric and piezoelectric properties.

imc-415 Gene Expression in the Proliferation and Cell Death Phases of Mammary Epithelial Cells

  • Ha, S.H.;Lee, D.Y.;Kho, Y.J.;Baik, M.G.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.9
    • /
    • pp.1201-1204
    • /
    • 2000
  • We examined expression patterns of imc-415 gene in mammary gland and in HC11 mammary epithelial cells in culture. mRNA levels of imc-415 gene were higher at pregnancy and involution stages of mouse mammary gland compared with lactation period. Expression of imc-415 gene was induced with serum starvation or treatment with Fas monoclonal antibody in HC11 mammary epithelial cells in culture.

Tribological Performance of Laser Textured Translucent Duplex α/β-Sialon Composite Ceramics

  • Joshi, Bhupendra;Tripathi, Khagendra;Gyawali, Gobinda;Lee, Soo Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.180-181
    • /
    • 2014
  • Optically translucent Sialon ceramics was fabricated by hot pressed sintering method. The Sialon ceramics was laser textured and their tribological performance was observed. Starved lubrication method was applied on Sialon ceramics with different dimple spacing under a load of 10N and at room temperature. The material having high dimple spacing ($200{\mu}m$) shows low coefficient of friction. The material shows mild wear and therefore, wear rate of steel ball (meeting partner) was observed to measure wear rate. Different phases Sialon ceramics were analyzed by XRD patterns. Moreover, the mechanical properties of the Sialon ceramics were observed.

  • PDF

LIGHT CURVE VARIATIONS OF AR LACERTAE

  • Nha, Il-Seong
    • Journal of Astronomy and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.149-158
    • /
    • 1991
  • Sixteen unitary Light curves of AR Lac in B and V are made at Yonsei University Observatory in the period of 1980-1988. Some overview findings of light variations are made. (1) The light variation outside eclipse follow none of the wave migration patterns reported by previous investigators. (2) Complicated shapes outside eclipse are apparently much reduced in the light curves of 1983-1984. This suggests than, in the future, AR Lac has a chance to attain a normal state with no complicated interactions. (3) The depths of the primary and the secondary mid-eclipses are changing year-to-year. (4) The K0 star, the larger component, has brightened by $0.^m$ 14 in V, while the G2 star has shown a fluctuation of about $0.^m$05 in V. (5) The B-V values at primary mid-eclipse have no correlation with the depth variations. (6) Independently of the increase of maximum brightness, the B-V colors in the non-eclipsed phases changed slightly over the years.

  • PDF

In Situ Microfluidic Synthesis of Monodisperse PEG Microspheres

  • Choi, Chang-Hyung;Jung, Jae-Hoon;Hwang, Taek-Sung;Lee, Chang-Soo
    • Macromolecular Research
    • /
    • v.17 no.3
    • /
    • pp.163-167
    • /
    • 2009
  • This study presents a microfluidic method for the production of monodisperse poly(ethylene glycol) (PEG) microspheres using continuous droplet formation and in situ photopolymerization in microfluidic devices. We investigated the flow patterns for the stable formation of droplets using capillary number and the flow rate of the hexade-cane phase. Under the stable region, the resulting microspheres showed narrow size distribution having a coefficient of variation (CV) of below 1.8%. The size of microspheres ($45{\sim}95{\mu}m$) could be easily controlled by changing the interfacial tension between the two immiscible phases and the flow rates of the dispersed or continuous phase.

Associations between Eating Behavior and the Eating Patterns of Female College Students Across the Menstrual Cycle (여대생의 월경주기에 따른 섭식패턴과 섭식행동의 관련성)

  • Kim, Seok-Young
    • Korean Journal of Community Nutrition
    • /
    • v.21 no.5
    • /
    • pp.405-414
    • /
    • 2016
  • Objectives: The associations between the eating behavior and energy and macronutrient intake from meals and snacks consumed during different times of the day across the menstrual cycle were investigated in 74 healthy female college students. Methods: A 9-day food record was collected during the last 3 days before menstrual onset (phase 1) and the first 3 days after menstrual onset (phase 2) and from the 4th to the 6th day after menstrual onset (phase 3), respectively. Anthropometry was assessed and eating behaviors were measured using the Dutch Eating Behavior Questionnaire (DEBQ). Results: External eating was the most prevalent type of eating behavior, followed by restrained eating and emotional eating. Restrained eating was positively associated with energy, carbohydrate and lipid intake at the breakfast and midmorning snack during phase 3. However, emotional eating was also positively related to energy and macronutrient intake at the dinner and after-dinner snack during phase 1 and phase 3, with higher level detected in the phase 1. The association of emotional eating with the snack consumption was highest in phase 1. External eating was positively associated with energy and macronutrient intakes at the dinner and after-dinner snack across the three phases, the highest level being phase 1. In addition, restrained eating was positively associated with the weight, body mass index(BMI), fat mass, waist and hip girth of the subjects. Conclusions: Eating behaviors varied with regard to meals and snacks consumed during different times of the day across the three menstrual phases. Dinner and afterdinner snack consumption in premenstrual phase could be considered as a time when women are more prone to overconsumption and uncontrolled eating.

Comparison of Motion Sensor Systems for Gait Phase Detection (보행주기 검출용 모션 센서 시스템의 비교)

  • Park, Sun-Woo;Sohn, Ryang-Hee;Ryu, Ki-Hong;Kim, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

Preparation of Porous Glass-Ceramics by the Sintering (소결법에 의한 다공질 결정화유리의 제조)

  • 박용완;이준영
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.10
    • /
    • pp.1218-1230
    • /
    • 1994
  • In manufacturing process of porous glass-ceramics by the filler method, the sintering behaviour of crystallizable glass powder mixed with various salts was studied and also the effects of precipitated crystal phases on the properties of porous glass-ceramics were investigated. Fine-grained crystallizable glass powder was homogeneously mixed with various slat having grain size 100~200 ${\mu}{\textrm}{m}$ and sintered for densification. After washing out the inorganic salt with distilled water, the porous sintered body was heat treated additionly for crystallization. The MgO-Al2O3-SiO2 base glass was used as crystallizable glass powder and the water soluble salts such as K2SO4 and MgSO4 were used as filler. When K2SO4 was used, leucite crystal phase was formed as a result of the ion exchange and porous glass-ceramics which exhibit high temperature resistance and high thermal expansion coefficient of 17$\times$10-6/$^{\circ}C$ could be obtained. On the contrary, when MgSO4 was used, only slight ion exchange is observed and $\mu$-cordierite and $\alpha$-cordierite crystal phases were formed and porous glass-ceramics which exhibit low thermal expansion coefficient schedule were determined with the results of DTA curves, thermal shrinkage curves and XRD patterns analysis. From DTA curves and thermal shrinkage curves, it was found that the sintering densification have been completed at the temperature range of exothermic peak for crystallization. The pore size distributions and pore diameters were measured by mercury porosimeter. The pore diameter of porous glass-ceramics was 10~15 ${\mu}{\textrm}{m}$ when 100~200${\mu}{\textrm}{m}$ grain size of K2SO4 was used and it was 25~30 ${\mu}{\textrm}{m}$ when the same grain size of MgSO4 was used. The porous glass-ceramics K2SO4 used shows bimodal pore size distribution and its porous skeleton structure was ascertained by SEM observation.

  • PDF