• Title/Summary/Keyword: Phaser

Search Result 7, Processing Time 0.014 seconds

Voltage-fed high frequency resonent inverter of instantaneous current phaser control method (순시 전류 phaser 제어방식의 전압형 고주파 공진 인버터)

  • LEE K.H.;RO C.K.;KIM D.H.;LEE B.S.;PARK J.K.;JUNG B.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.348-351
    • /
    • 2001
  • In this paper, voltage-fed high frequency resonant inverter of instantaneous current phaser control method used to DC voltage source separated is proposed. In the output control method, a novel circuit type of phase shift driving signal method with CVCF illustrated, also the operation principle of the proposed circuit is described in detail and its characteristics are presented as to normalized parameters. According to the each mode, in order to the circuit analysis and characteristic evaluation of the state equation are derives and present used to normalized parameter. In the future, this proposed inverter show that it can be practically used as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF

업계소식

  • Korea Electronics Association
    • Journal of Korean Electronics
    • /
    • v.11 no.2
    • /
    • pp.68-71
    • /
    • 1991
  • PDF

Analysis of Step-up AC/DC Converter (승압형 AC/DC 전력 변환기의 해석)

  • Park, S.Y.;Park, I.G.;Kang, Y.S.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.340-343
    • /
    • 1990
  • Recently, Power Electronics system increase makes harmonics and low input power factor problem. In this paper present new analysis method of PWM Boost AC/DC Converter. This PWM AC/DC Converter is capability of unity power factor, control of DC side voltage level, generation, and near sinusoidal current in 3-phase line. The control of this type of converter is widely discussed. And this paper propose new phase convert function and analysis in steady state of system to obtain amplitude and phaser of switching function. This switching function is general solution and it can use in high power approach. And this control method show the clear meaning of control variable. This paper propose new analysis method of Boost AC/DC Converter of steady state and 3-phase 2KW experimental system show its validity.

  • PDF

Estimation of Power System Parameters using Synchronized Phaser Measurements (동기 페이저 측정치를 이용한 전력계통 매개변수 추정)

  • Song, Shi-Cheol;Cho, Ki-Seon;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.80-84
    • /
    • 2000
  • Network parameters in power systems are indispensable for all of power system engineering studies, including the power flow calculation and the state estimation. The network parameters required for the studios, in general, are estimated by using several estimation techniques, since it Is very difficult to measure. To improve the estimation accuracy of the network parameters, this paper adopt the synchronized phasor measurements which are acquired from the Phasor Measurement Unit with built-in GPS receiver. In this paper, the parameter estimation problem is formulated with over-determined nonlinear measurement equations and solved with Newton-Raphson method and pseudo-inverse. The effectiveness of the proposed parameter estimation with the synchronized phasor measurements is verified through some case studies with IEEE sample system. The results are very promising.

  • PDF

Crystal Growth and Phase Transition of Piezoelectric $KAlSiO_4$ (압전성 $KAlSiO_4$ 단결정 육성 및 상변화)

  • 오광석;박봉모;정수진;이태근;박병규;김호성
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.3
    • /
    • pp.362-370
    • /
    • 1996
  • Kalsilite (KAlSiO4) system undergoes a displacive phase transition from hexagonal phase with p63 space group to the phase with P63mc at 886$^{\circ}C$. The flux composition having kalsilite :K2O:B2O3=1:2:2 has enabled the growth of hexagonal kalsilite with the size of 0.5~1 mm at a slow cooling rate (0.3$^{\circ}C$/hr). On decreasing the cooling rate the size has increased and pyramidal (1011) faces are newly developed with the shape of (0001) and (1010) faces. Upon stirring (1011) faces are degraded. The space group of O1 and O2 are P21221 and C2221 respectively. Their orthorombic modification O1 and O2 are synthesized at relatively low and high temperature respectively.

  • PDF

Electrochemical Properties of SnCo for Anode Material of Li Ion Batteries (리튬 이온 전지 음극 재료용 SnCo의 전기화학적 특성)

  • Kim, Ki-Tae;Kim, Yong-Mook;Lee, Yong-Ju;Lee, Ki-Young;Lee, Jai-Young
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.3
    • /
    • pp.242-248
    • /
    • 2002
  • SnCo alloy powder prepared by high energy ball milling is examined as an anode material for lithium-ion batteries. As the ball-milling time increased, the crystallinity of SnCo decreased. XRD and TEM SADP showed that nanocrystalline and amorphous phase coexisted after 16 h ball-milling. As the crystallinity decreased, the cycleability increased. At first cycle, there are 4 plateau potentials. The observation of voltage plateau at about 0.68 V confirms the formation of Sn-Li alloy and Co metal. It is considered that The plateau potentials below 0.68 V were reaction between Li and Sn. The change of chemical diffusion coefficient showed that the structure of SnCo alloy abruptly changed at first cycle, and maintained after 2nd cycle.

An Improved Two-Terminal Numerical Algorithm of Fault Location Estimation and Arcing Fault Detection for Adaptive AutoReclosure (고속 적응자동재폐로를 위한 사고거리추정 및 사고판별에 관한 개선된 양단자 수치해석 알고리즘)

  • Lee, Chan-Joo;Kim, Hyun-Houng;Park, Jong-Bae;Shin, Joong-Rin;Radoievic, Zoran
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.11
    • /
    • pp.525-532
    • /
    • 2005
  • This paper presents a new two-terminal numerical algorithm for fault location estimation and for faults recognition using the synchronized phaser in time-domain. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the assumed PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. Also the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. In this paper the algorithm is given and estimated using DFT(discrete Fourier Transform) and the LES(Least Error Squares Method). The algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm, the Electro-Magnetic Transient Program(EMTP/ATP) is used.