• Title/Summary/Keyword: Phase-to-ground

Search Result 954, Processing Time 0.034 seconds

Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line (전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.

Relationship between Phase Properties, Significant Duration and PGA from the Earthquake Records of Mw 5.5~6.5 (Mw 5.5~6.5 지진동의 위상특성과 계속시간 및 PGA와의 관계)

  • Choi, Hang;Yoon, Byung Ick
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.55-70
    • /
    • 2019
  • The phase properties of ground acceleration records from Mw 5.5~6.5 earthquakes are analyzed. The interrelationships between phase properties and significant durations, as well as PGA, are clarified through both of theoretical and empirical approaches. The probabilistic characteristics of phase information is also discussed based on previous studies and it is shown that circular normal distribution is the most appropriate probability distribution for the phase angle and phase difference. Whereas those variates can be modeled by Gaussian random variables. From the survey results on the frequency dependency of the phase statistics, a simple model is introduced, which is possible to express the frequency dependency of phase information. It is also shown that the significant duration can be controlled by appropriately chosen standard deviation of phase difference for 4~8Hz frequency band and additional consideration of phase scattering in higher frequency band through a series of Monte Carlo simulations. The source of phase scattering effect is also pointed out and discussed.

Zero Sequence Impedance of Yg-Yg Three Phase Core Type Transformer (Yg-Yg 3상 내철형 변압기의 영상분 임피던스 분석)

  • Jo, Hyunsik;Cho, Sungwoo;Shin, Changhoon;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.940-945
    • /
    • 2016
  • In this paper, zero sequence equivalent circuit of Yg-Yg three phase core-type transformer is analyzed. Many problems by iron core structure of the three phase transformer due to asymmetric three phase lines, which includes line disconnection, ground fault, COS OFF, and unbalanced load are reported in the distribution system. To verify a feasibility of zero sequence impedance of Yg-Yg type three phase transformer, fault current generation in the three phase core and shell-type Yg-Yg transformer is compared by PSCAD/EMTDC when single line ground fault is occurred. As a result, shell-type transformer does not affect the flow of fault current, but core-type transformer generate an adverse effect by the zero sequence impedance. The adverse effect is explained by the zero sequence equivalent circuit of core-type transformer and Yg-Yg type three phase core-type transformer supplies a zero sequence fault current to the distribution system.

Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL (분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

Study of Short-Circuit Currents Around Dĕtmarovice Power Station

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.3
    • /
    • pp.117-124
    • /
    • 2014
  • The calculation of short-circuit currents is important for power systems operation and restoration, and for determining the means to protect human lives and properties. In this paper, a part of a power system network, around the D$\breve{e}$tmarovice power station in Czech Republic, was simulated by the well known program EMTP-ATPDraw (Electromagnetic Transients Program-Alternative Transient Program), and short-circuit currents and voltages were calculated at different points in the electric network and presented as a time function by the PlotXY program. Calculations were done just for phase-to-ground, and for the three-phase short-circuit at the Kun$\check{c}$ice substation. The results were important for determining the characteristics of the equipment required to withstand or break the short-circuit current; for this reason, the calculations were repeated using earth-fault resistances only for the case of busbar KUN shown in Figs. 5 and 6.

A Study on the Zone Setting of Digital Distance Relay (디지털 거리계전기의 Zone 설정에 관한 연구)

  • Lee, Jae-Gyu;Jung, Chang-Ho;Jung, Byung-Tae;Ahn, Bok-Shin;Kim, Sok-Il
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.946-948
    • /
    • 1998
  • The distance relay is very important for transmission line protection. A quadrilateral zone shape is used mainly for a modern digital distance relay. The shape of quadrilateral is vendor specific. At the stage of design, the shape is determined considering all possible types of faults and diverse configurations of system. Also this type relay must be designed to avoid the operation by a sound phase at single-Phase-to-ground fault, by a sound phase at two-phase-to-ground fault. The effect of a source impedance and a load impedance is another important factor to design. In this paper, a reliable zone shape which is appropriate for the KEPCO's transmission system is provided.

  • PDF

A Kinematic Analysis of the Defence Types during Body Lock Technique in the Ground Wrestling (그라운드 레슬링 가로들기 공격 시 수비 유형의 운동학적 분석)

  • Hah, Chong-Ku;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.155-164
    • /
    • 2007
  • This study is to find out effective defensive type by analysis on differences among three different defence types of the body lock technique in the ground wrestling. The subjects are 5 athletes who are in 60kg weight class. To get the kinematic analysis seven ProReflex MCU-240(Motion Capture Unit), infrared rays cameras, which was produced by Qualisys, were used to get a two-dimensional coordinate. Following are the analysis result from kinematic factors such as time element, speed element and angular element. 1. During position of ground wrestling, the average necessary time until defender's hip joint touches the mat for Phase1 was $0.34{\pm}0.14sec$ at side position was the shortest space of time out of three types, and Phase2 was $0.21{\pm}0.02sec$ at front position was the shortest space of time out of three types. Moreover, side defence position was the shortest for total average necessary time with $0.78{\pm}0.05sec$. 2. The movement change for hip joint was $57.21{\pm}20.17cm$ for front, $43.35{\pm}7.13cm$ for rear, and $18.67{\pm}10.24cm$ for side at Phase1 and $42.08{\pm}17.56cm$ for side, $16.61{\pm}6.34cm$ for front, and $1.48{\pm}1.29cm$ for rear at Phase2. 3. Movement speed of hip joint at defensive type were most effective in success and fail rate at Phase 1 and its frontal average speed was fastest with $1.01{\pm}0.23m/s$ following by $0.52{\pm}0.15m/s$ for side, and $0.62{\pm}0.15m/s$ for rear. The average for total change of speed is $0.79{\pm}0.32m/s$ for front, $0.78{\pm}0.17m/s$ for side, and $0.49{\pm}0.08m/s$ for rear. 4. The joint angle gets smaller in a order by rear, front, and side for the size of hip joint angle and knee angle for different defensive type. 5. As a result of one-way ANOVA on linear velocity for hip joint in frontal defence(phase1) was significance ($\alpha$=.05), but phase 2 was not significance. Synthetically, analyzing on differences among three different defence types which were front, rear, and side of the body lock technique in the ground wrestling, front defensive type was the most effective. In future, there should be more studies regarding on defence at not a laboratory study but a field study to help out wrestler to pertinent techniques to improve the game of wrestling.

On the variability of strong ground motions recorded from Vrancea earthquakes

  • Pavel, Florin;Vacareanu, Radu;Arion, Cristian;Neagu, Cristian
    • Earthquakes and Structures
    • /
    • v.6 no.1
    • /
    • pp.1-18
    • /
    • 2014
  • The main focus of this paper is the analysis of the different components of the variability for strong ground motions recorded from earthquakes produced by the Vrancea subcrustal seismic source. The analysis is performed for two ground motion prediction equations: Youngs et al. (1997) and Zhao et al. (2006), recommended within the SHARE project for the Vrancea subcrustal seismic source and which are proposed in the work of Delavaud et al. (2012) and graded best in Vacareanu et al. (2013c). The first phase of the analysis procedure consists of a grading procedure. In the second phase, the single station sigma procedure is applied for both attenuation models in order to reduce some parts of ground motion models' variability produced by the ergodic assumption. The strong ground motion database which is used throughout the study consists of over 400 accelerograms recorded from 9 Vrancea intermediate-depth seismic events. The results of the single station sigma analysis show significant reduction of the standard deviations, especially in the case of the Youngs et al. (1997) attenuation model, which is also graded better than the other selected GMPE.

Comparison of Lower Extremity Electromyography and Ground Reaction Force during Gait Termination according to the Performance of the Stop Signal Task (정지신호과제의 수행에 따른 보행정지 시 다리 근전도 및 지면반발력 비교)

  • Koo, Dong-Kyun;Kwon, Jung-Won
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.135-145
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the association between cognitive and motor inhibition by comparing muscle activity and ground reaction force during unplanned gait termination according to reaction time measured through the stop-signal task. Methods: Sixteen young adults performed a stop-signal task and an unplanned gait termination separately. The subjects were divided into fast and slow groups based on their stop-signal reaction time (SSRT), as measured by the stop-signal task. Electromyography (EMG) and ground reaction force (GRF) were compared between the groups during unplanned gait termination. The data for gait termination were divided into three phases (Phase 1 to 3). The Mann-Whitney U test was used to compare spatiotemporal gait parameters and EMG and GRF data between groups. Results: The slow group had significantly higher activity of the tibialis anterior in Phase 2 and Phase 3 than the fast group (p <0.05). In Phase 1, the fast group had significantly shorter time to peak amplitude (TPA) of the soleus than the slow group (p <0.05). In Phase 2, the TPA of the tibialis anterior was significantly lower in the fast group than the slow group (p <0.05). In Phase 3, there was no significant difference in the GRF between the two groups (p >0.05). There were no significant difference between the two groups in the spatiotemporal gait parameters (p >0.05). Conclusion: Compared to the slow group, the fast group with cognitive inhibition suppressed muscle activity for unplanned gait termination. The association between SSRT and unplanned gait termination shows that a participant's ability to suppress an incipient finger response is relevant to their ability to construct a corrective gait pattern in a choice-demanding environment.