• Title/Summary/Keyword: Phase-Difference Parameters

Search Result 247, Processing Time 0.028 seconds

A Speed Characteristics of the Ultrasonic Motor by the Multi-Parameters adjustment with Phase difference-Frequency (위상차-주파수 다중 파라미터 조절에 의한 초음파 모터 속도 특성)

  • Kim, Dong-Ok;Kang, Won-Chan;Kim, Sung-Cheol;Oh, Geum-Kon;Kim, Young-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.1
    • /
    • pp.20-27
    • /
    • 2003
  • In this study, we designed and made Ultrasonic motor-digital multi controller(USM-DMC) using FPGA chip, A54SX72A made in Actel Corporation. By the minute, USM-DMC can adjust the frequency, duty ratio, and phase difference parameters of USM by digital input to be each 11bit from PC. Therefore, when we use this controller, it is possible to apply typical three parameters individually as well as multi-parameters simultaneously to control the speed and the torque. What is more, the strongest point is that it can trace frequency based on optimized frequency as compared with the phase difference because we can input optimized resonant frequency while in motoring. And we test the speed of USM with the adjustment of multi-parameters, the phase difference-frequency. As the result of the test, in the case of the multi-parameters of the phase difference and frequency, the speed characteristic is more linear and stable, and wider in the range of control than the single-parameter of the phase difference or the frequency.

SAR Data Correction Based on Calibrated-Scatterometer Measurements (보정된 Scatterometer의 측정데이터를 사용한 SAR 데이터 교정)

  • 정구준;홍진영;오이석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • This paper presents an SAR-data calibration technique using a well-calibrated scatterometer. At first a fully-polarimetric antenna pattern(magnitude and phase) of the antenna main-beam using a conducting sphere was measured. Then, this data were used to calibrate polarimetrically an auto-mounted network analyzer-based scatterometer system. This scatterometer system can be used to measure the accurate Mueller matrices of earth surfaces such as grass fields, rice fields and bare soil surfaces; i.e., the phase-difference parameters can be obtained as well as the radar scattering coefficients. If a polarimetrically calibrated scatterometer is operated at the same time with the SAR system, the scatterometer data can be used to correct the SAR data, especially the phase-difference parameters. It was found that the correction effect is remarkable for the degree of correlation ${\alpha}$, which is one of the phase-difference parameter, while the correction effect is negligible for the magnitude parameters(backscattering coefficients).

Characteristics of Ultrasonic Motor using Voltage Control and Phase Difference Control (초음파 모터의 전압 및 위상차 제어 특성)

  • Shin, Duk;Kim, Dong-Ok;Ko, Nak-Yong;Choi, Han-Soo;Kim, Young-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.949-952
    • /
    • 1996
  • The ultrasonic motor(USM) has good characteristics such as compact size, silent motion, low speed, high torque and high speed response. The USM is driven by 2-phase AC electricity. The control parameters of USM are voltage, phase difference, frequency of input power, etc. In this paper, we propose voltage difference control. And we designed USM controller to adjust voltage and phase using pLSI(programmable Large Scale Integration). Voltage difference control has many advantages that are lower current, lower power than phase difference control. Especially there is nearly zero ampere at the zero point of speed and torque. we can apply this voltage difference control to the compliance control of DD manipulator.

  • PDF

The study on Reactor Parameters of Atmosphere Plasma Power Supply (대기압 플라즈마 전원장치의 반응기 파라메터에 관한 연구)

  • Lee, Woo-Cheol;Lee, Taeck-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.59-65
    • /
    • 2012
  • This paper presents a digital control solution which can extract the reactor parameters in atmosphere plasma power supply. The critical issue of the atmosphere plasma power supply is a impedance matching. For the impedance matching, the reactor parameters should be known, but the parameters depend on the reactors. Therefore, the reactor parameters have to measure for the impedance matching. The proposed method is performed by detection of phase difference between inverter voltage and current, and extraction of impedance through active, reactive power.

Prediction of Fatigue Crack Initiation Direction around a Hole under Biaxial Loads Considering Phase Difference and Biaxiality (이축성과 위상차의 영향을 고려한 이축 하중하에서 구멍 주위에서의 피로 균열 발생 방향 예측)

  • Huh, Yong-Hak;Park, Pil-Ip;Kim, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.156-161
    • /
    • 2004
  • To predict the direction of the fatigue crack initiated from a hole under various types of biaxial fatigue loads with different phase difference and biaxiality, fatigue parameters were investigated. Axial and torsional biaxial fatigue loads were selected with the respective combination of five different phase differences of 0, 45, 90, 145 and 180 degrees and five biaxialities of 0, $1/{\sqrt{3}}$, 1, ${\sqrt{3}}$, ${\infty}$. Directions of the fatigue crack initiation around the hole were found to approach to the circumferential direction of the specimen with increment of the phase difference for fatigue tests with phase differences less than $90^{\circ}$. Whereas directions for tests with phase differences greater than $90^{\circ}$ went away from the circumferential direction and those were symmetric to the directions for tests with phase difference less than $90^{\circ}$. With increase of biaxilities, the fatigue crack initiated more apart from the circumferential direction of the specimen. These crack initiation direction were predicted using maximum tangential stress range and maximum shear stress range obtained at far-field and around the hole. Comparing these two stress parameters, The crack initiation direction can be successfully explained by using the direction of the maximum tangential stress range obtained around the hole and at far-field.

  • PDF

DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE (저온도차 모형 스털링 엔진의 최대출력 설계조건)

  • Jung, P.S.;Won, M.Y.;Kim, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

Speed and Torque characteristics of Ultrasonic Motor by Voltage difference control (전압차 제어에 의한 초음파 모터의 속도 및 토오크 특성)

  • 김영동;오금곤
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.6
    • /
    • pp.88-95
    • /
    • 1996
  • The ultrasonic motor(USM) has good characteristics such as compact size, silent motion, high speed responce, low speed and high torque. The USM is driven by 2-phase AC electricity. The control parameters of USM are voltage, phase, and frequency of input powers, etc. In this paper, a voltage difference control is proposed. The voltage difference control has more advantage than phase difference control. Specially, current and power is lower than that of phase difference control. For this voltage diffrence control, we designed USM controller to adjust volatage and phase using PLSI(Programmable Large Scale Integration).

  • PDF

A Study on the Heterodyned Optical Phase Locked Loop (헤테로다인 광 위상 고정 루프 연구)

  • Yoo, Kang-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1163-1171
    • /
    • 2007
  • In this paper, the design techniques required to design heterodyned OPLL such as frequency-phase deference detector, loop filter and phase noise of semiconductor laser are presented. Through the experiments with the calculated parameters, we confirmed that the frequency-phase difference detector simply develops an error component that is proportional to the frequency-phase difference between heterodyned optical signals. The achieved frequency-phase locking range of the input laser diode frequency is around ${\pm}150MHz$. This paper describes the details of the designed as well as experimental results.

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

A Semi-empirical Model for Polarimetric Radar Backscattering from Bare Soil Surfaces

  • Oh, Yi-Sok
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.2
    • /
    • pp.141-153
    • /
    • 2001
  • A semi-empirical polarimetric backscattering model for bare soil surfaces is presented. Based on measurements by using polarimetric scatterometers and the JPL AirSAR, as well as the theoretical models, the backscattering coefficints $\sigma$$^0_w$, $\sigma$$^0_{hh}$ and $\sigma$$^0_{vh}$, and the parameters of the copolarized phase-difference probability density function, namely the degree of correlation $\alpha$ and the copolarized-phase-difference $\zeta$, are modeled empirically in terms of the volumetric soil moisture content m$_v$ and the surface roughness parameters $k_s$ and $k_l$, where k=2$\pi$f/c, s is the rms height and l is the correlation length.