• Title/Summary/Keyword: Phase variation

Search Result 2,043, Processing Time 0.023 seconds

A Study on Discharge Statistics Quantities for Deterioration Diagnosis of Branch-type Tree (가지형 트리의 열화진단을 위한 방전통계량에 관한 연구)

  • Shin, S.K.;Kim, K.M.;Kim, T.Y.;Lee, D.J.;Park, C.O.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2345-2348
    • /
    • 1999
  • Existing $\psi$-AEA-t (phase-AEA-time) characteristic in polymer materials for power cable is good in general deterioration characteristic according to time variation, but it is difficult to clearly distinguish from deterioration state and diagnosis of deterioration is not enough to some extent. This paper is interpreted AE discharge statistics quantities measuring phase-amplitude variation of acoustic emission characteristic obtained from treeing breakdown experiment. Besides it can know useful discharge statistics quantities (AE average inception phase/amplitude, AE average maximum phase/amplitude) about so many for diagnosis of treeing deterioration.

  • PDF

Advanced SOGI-FLL Scheme Based on Fuzzy Logic for Single-Phase Grid-Connected Converters

  • Park, Jin-Sang;Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.598-607
    • /
    • 2014
  • This paper proposes a frequency-locked loop (FLL) scheme for a single-phase grid-connected converter. A second-order generalized integrator (SOGI) based on fuzzy logic (FL) is applied to this converter to achieve precise phase angle detection. The use of this method enables the compensation of the nonlinear characteristic of the frequency error, which is defined in the SOGI scheme as the variation of the central frequency through the self-tuning gain. With the proposed scheme, the performance of the SOGI-FLL is further improved at the grid disturbances, which results in the stable operation of the grid converter under grid voltage sags or frequency variation. The PSIM simulation and experimental results are shown to verify the effectiveness of the proposed method.

Mg II LINE VARIATION OF 32 CYGNI

  • Kang, Young-Woon
    • Journal of Astronomy and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.154-164
    • /
    • 1992
  • The Mg II lines been extracted from the IUE archival spectra of 32 Cygni to investigate the effect of the atmospheric eclipse. The UV light curve has been reduced from the continuum flux at the center wavelength of 2807.5 ${\AA}$ in the IUE spectra. The equivalent width of the Mg II k absoption line has been measured for each spectra. The results of the light variation and flux tracing of the absorption line at the vicinity of the primary eclipse confirmed the atmospheric eclipse. The atmospheric effect lasted until the phase 0.06 in the absorptin line tracing, while it lasted until the phase 0.02 in the UV light curve, respectively.

  • PDF

Loop Filter Voltage Variation Compensated PLL with Charge Pump (전하펌프를 이용한 루프 필터 전압변화 보상 위상고정루프)

  • An, Seong-Jin;Choi, Yong-shig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1935-1940
    • /
    • 2016
  • This paper proposes a phase-locked loop (PLL) to minimize the loop filter output voltage fluctuation by using a comparator including RC time constant circuits. The voltage variation of loop filter is inputted to RC time constant circuits which have two RC time constants, large and small. While a small RC time constant circuit quickly conveys the output voltage variation of loop filter, a large RC time constant circuit conveys slowly the output voltage variation of loop filter and its output looks like constant voltage. The output signal of the comparator controls the sub charge pump and reduces the input voltage variation of voltage-controlled oscillator (VCO). Therefore, the proposed PLL generates a phase noise reduced signal. It has been designed with a 1.8V supply voltage, 0.18um multi - metal and multi - poly layer CMOS process and proved by Hspice simulation.

Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition (여러 환경조건에 대한 고분자애자의 누설전류 특성 변화)

  • Park Jae-Jun;Choi In-Hyuk;Lee Dong-il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

N.M.for the Effect of P.T. on Resicual Stress Relaxation (잔류응력 완화에 미치는 상변태의 수치적 모델링)

  • 장경복;손금렬;강성수
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.84-89
    • /
    • 1999
  • Most of ferrous b.c.c weld materials may experience martensitic transformation during rapid cooling after welding. It is well known that volume expansion due to the phase transformation could influence on the relaxation of welding residual stress. To apply this effect practically, it is a prerequisite to establish a numerical model which is able to estimate the effect of phase transformation on residual stress relaxation quantitatively. For this purpose, the analysis is carried out in two regions. i.e., heating and cooling, because the variation of material properties following a phase transformation in cooling is different in comparison with the case in heating, even at the same temperature. The variation of material properties following phase transformation is considered by the adjustment of specific heat and thermal expansion coefficient, and the distribution of residual stress in analysis is compared with that of experiment by previous study. consequently, in this study, simplified numerical procedures considering phase transformation, which based on a commercial finite element package was established through comparing with the experimental data of residual stress distribution by other researcher. To consider the phase transformation effect on residual stress relaxation, the transition of mechanical and thermal property such as thermal expansion coefficient and specific heat capacity was found by try and error method in this analysis.

  • PDF

Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe (사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발)

  • Lee, Kyoung-Hwang;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

A Method of Lane Marker Detection Robust to Environmental Variation Using Lane Tracking (차선 추적을 이용한 환경변화에 강인한 차선 검출 방법)

  • Lee, Jihye;Yi, Kang
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.12
    • /
    • pp.1396-1406
    • /
    • 2018
  • Lane detection is a key function in developing autonomous vehicle technology. In this paper, we propose a lane marker detection algorithm robust to environmental variation targeting low cost embedded computing devices. The proposed algorithm consists of two phases: initialization phase which is slow but has relatively higher accuracy; and the tracking phase which is fast and has the reliable performance in a limited condition. The initialization phase detects lane markers using a set of filters utilizing the various features of lane markers. The tracking phase uses Kalman filter to accelerate the lane marker detection processing. In a tracking phase, we measure the reliability of the detection results and switch it to initialization phase if the confidence level becomes below a threshold. By combining the initialization and tracking phases we achieved high accuracy and acceptable computing speed even under a low cost computing resources in which we cannot use the computing intensive algorithm such as deep learning approach. Experimental results show that the detection accuracy is about 95% on average and the processing speed is about 20 frames per second with Raspberry Pi 3 which is low cost device.

A Study on the Improvement of the IM Speed Control Characteristics with Load Torque Variation (부하 변동에 대한 유도 전동기의 속도 제어 특성에 관한 연구)

  • 강문호;김남정;유기윤;박귀태;민경일
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1075-1083
    • /
    • 1994
  • In this paper, a study on the improvement of the IM speed response against load torque variation is presented. A VSCS(Variable Structure Control System) is proposed which gives the desired robustness against load torque variation using a new kind of time-varing switching plane. In order to eliminate the reaching phase of the states from one switching plane to another during variation, the switching plane is varied continuously. To verify the high dynamic performance of the proposed VSCS, simulation and experimental results are presented.

7-Phase BLDC Motor Drive System using MSTC (MSTC를 이용한 7상 BLDC 모터 구동시스템)

  • 전윤석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.429-433
    • /
    • 2000
  • Recently the demand of motor for industrial household machinery is increasing. As Switching devices and control technology are progressing so the use of BLDC Motor is increasing But 3-Phase BLDC Motor generally used has pulsating torque and speed variation in commutation so the range of it's application is limited high speed application Especially to solve these problems it is necessary to increase phase to Motor so study of Poly-Phase BLDC Motor is progressing. In this paper we designed 7-Phase BLDC Motor drive system and MSTC(Minimum Switching Time Controller)

  • PDF