• Title/Summary/Keyword: Phase transfer

Search Result 2,010, Processing Time 0.031 seconds

A Frequency-Tracking Method Based on a SOGI-PLL for Wireless Power Transfer Systems to Assure Operation in the Resonant State

  • Tan, Ping-an;He, Haibing;Gao, Xieping
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1056-1066
    • /
    • 2016
  • Wireless power transfer (WPT) technology is now recognized as an efficient means of transferring power without physical contact. However, frequency detuning will greatly reduce the transmission power and efficiency of a WPT system. To overcome the difficulties associated with the traditional frequency-tracking methods, this paper proposes a Direct Phase Control (DPC) approach, based on the Second-Order Generalized Integrator Phase-Locked Loop (SOGI-PLL), to provide accurate frequency-tracking for WPT systems. The DPC determines the phase difference between the output voltage and current of the inverter in WPT systems, and the SOGI-PLL provides the phase of the resonant current for dynamically adjusting the output voltage frequency of the inverter. Further, the stability of this control method is analyzed using the linear system theory. The performance of the proposed frequency-tracking method is investigated under various operating conditions. Simulation and experimental results convincingly demonstrate that the proposed technique will track the quasi-resonant frequency automatically, and that the ZVS operation can be achieved.

A Novel Parameter-independent Fictive-axis Approach for the Voltage Oriented Control of Single-phase Inverters

  • Ramirez, Fernando Arturo;Arjona, Marco A.;Hernandez, Concepcion
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.533-541
    • /
    • 2017
  • This paper presents a novel Parameter-Independent Fictive-Axis (PIFA) approach for the Voltage-Oriented Control (VOC) algorithm used in grid-tied single-phase inverters. VOC is based on the transformation of the single-phase grid current into the synchronous reference frame. As a result, an orthogonal current signal is needed. Traditionally, this signal has been obtained from fixed time delays, digital filters or a Hilbert transformation. Nevertheless, these solutions present stability and transient drawbacks. Recently, the Fictive Axis Emulation (FAE) VOC has emerged as an alternative for the generation of the quadrature current signal. FAE requires detailed information of the grid current filter along with its transfer function for signal creation. When the transfer function is not accurate, the direct and quadrature current components present steady-state oscillations as the fictive two-phase system becomes unbalanced. Moreover, the digital implementation of the transfer function imposes an additional computing burden on the VOC. The PIFA VOC presented in this paper, takes advantage of the reference current to create the required orthogonal current, which effectively eliminates the need for the filter transfer function. Moreover, the fictive signal amplitude and phase do not change with a frequency drift, which results in an increased reliability. This yields a fast, linear and stable system that can be installed without fine tuning. To demonstrate the good performance of the PIFA VOC, simulation and experimental results are presented.

비선형 위상을 가지는 화염전달함수 (A Flame Transfer Function with Nonlinear Phase)

  • 윤명곤;김진아;김대식
    • 한국추진공학회지
    • /
    • 제20권3호
    • /
    • pp.78-86
    • /
    • 2016
  • 본 논문은 가스터빈시스템에서 외부 유량의 섭동과 이에 따른 열발생의 섭동 사이의 관계를 표현하는 새로운 형태의 화염전달함수(flame transfer function))를 제안한다. 연소의 불안정성을 예측하기 위하여 그 동안 널리 이용되어 왔던 $n-{\tau}$ 모델과 본 논문에서 제안하는 모델과의 가장 큰 차이점은 주파수 변화에 따른 위상의 비선형적인 관계를 표현 할 수 있다는 점에 있다. 기존의 $n-{\tau}$ 모델의 경우 위상은 항상 주파수의 선형함수로 주어지는데 이는 실제 연소시스템의 실험에서 자주 관측되는 결과와 일치하지 않았다. 실험 결과를 바탕으로 새로운 화염전달함수 모델을 구성하였고 연소불안정성의 측면에서 위상의 비선형성이 미치는 영향에 관하여 분석하였다.

狀移動重合. Tetrabutylammonium Bromide 존재하에서 Diphenoxides와 1,6-Dibromohexane의 二狀重縮合反應 (Phase Transfer Polymerization. Two Phase Polycondensation of Diphenoxides and 1,6-Dibromohexane in the Presence of Tetrabutylammonium Bromide)

  • 진정일;정용운;이광섭;정근우
    • 대한화학회지
    • /
    • 제23권4호
    • /
    • pp.259-266
    • /
    • 1979
  • 수용액상에 존재하는 2,2-비스(4-히드록시페닐)프로판, 황화비스(4-히드록시페닐) 및 비스(4-히드록시페닐)술폰의 음이온과 니트로벤젠속에 존재하는 1,6-디브르모헥산을 브롬화테트라부틸 암모늄을 상이동 촉매로 사용하여 반응시켜 새로운 폴리에테르를 합성하였다. 중합속도는 교반속도와 촉매량에 의존하였으나 어느정도 이상에서는 영향을 받지 않았다. 분배실험으로 부터 친수성 음이온이 촉매에 의하여 니트로벤젠 층으로 상이동함을 확증하였으며 일부 중합체의 본성점성도 (0.09∼0.16), 수평균분자량 (2400∼4800) 및 열안정성등을 조사하였다. 이와같은 중합 메카니즘은 소위 interfacial polymerization의 메카니즘과 다르며, 이를 구별하기 위하여 "상이동 중합''(phase transfer polymerization) 이란 용어를 사용할 것을 제안한다.

  • PDF

Micro Fourier Rheometer에 의한 알루미나 그린 테이프의 Complex Modulus 측정 (Complex Modulus of Alumina Green Tapes Measured by Micro Fourier Rheometer)

  • 이정훈;이명현;김창은;김대준
    • 한국세라믹학회지
    • /
    • 제36권2호
    • /
    • pp.122-129
    • /
    • 1999
  • 알루미나 분말/(알루미나+결합체+가소제)의 비(X)와 결합체/(결합체+가소제)의 비(Y)를 각각 변화시켜 제조한 알루미나 그린 테이프의 complex modulus를 Micro Fourier Rheometer를 이용하여 측정하였다. X와 Y의 증가에 따라 Transfer function(TF) magnitude는 증가하고 Transfer function(TF) phase는 감소하는 경향을 보였으며 이로부터 X비와 Y비의 증가가 테이프의 탄성을 증가시켜는 요인임을 알 수 있었다. 온도가 증가함에 따라 알루미나 테이프의 TF magnitude는 작아지고 TF phase는 커지는 것으로부터 테이프의 점성이 증가함을 알 수 있었다. 특히 Y비에 따른 complex modulus의 변화는 유리전이온도와 관련이 있으며 변화값은 측정 조성 범위 내에서 X비에 의한 변화값보다 큼을 볼 수 있었다. complex modulus 측정을 통하여 알루미나 테이프의 성형이 가능하기 위해서는 TF phase 값이 17$^{\circ}$이상이어야 함을 유추할 수 있었다.

  • PDF

Effect of Micro Grooves on the Performance of Condensing Heat Transfer of the Micro Grooved Thermosyphons

  • Han, Kyu-Il;Cho, Dong-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.184-191
    • /
    • 2002
  • This study concerns the performance of the condensing heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal micro grooves. Distilled water, methanol, ethanol have been used as the working fluid. The numbers of grooves and operating temperature have been investigated as the experimental parameters. Condensing heat transfer coefficients and heat flux are obtained from experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, numbers of grooves are very important factors for the operation of thermosyphons. The working fluid with high latent heat such as water has a good heat transfer rate compared to methanol and ethanol. The relatively high rate of heat transfer is achieved when the thermosyphon with internal micro grooves is used compared to that with plain tube. Condensing heat transfer coefficient of grooved thermosyphon is 1.5∼2 times higher in methanol and 1.3∼l.5 times higher in ethanol compared to plain tube. The best condensation heat transfer performance is obtained for 60 grooves, and the maximum value of this case is 2.5 times higher than that of the plain tube.

삼상슬러리 기포탑에서 액상의 표면장력이 열전달 계수에 미치는 영향 (Effects of Liquid Surface Tension on the Heat Transfer Coefficient in a Three-Phase Slurry Bubble Column)

  • 임호;임대호;진해룡;강용;정헌
    • Korean Chemical Engineering Research
    • /
    • 제50권3호
    • /
    • pp.499-504
    • /
    • 2012
  • 산업현장에서 자주 접하는 액상의 물성인 표면장력이 상대적으로 작은 액상으로 구성된 삼상슬러리 기포탑에서 총괄 열전달 특성을 고찰하였다. 기포탑 내부의 열전달 현상은 기포탑 내부의 수직 열원과 기포탑 간의 열전달계를 구성하여 고찰하였으며 열전달 계수는 정상상태에서 열원표면의 온도와 기포탑 내부의 평균 온도의 차를 측정하여 결정하였다. 기체유속($U_G$), 슬러리 상에 포함된 고체입자의 분율($C_S$) 그리고 연속 액상의 표면장력(${\sigma}_L$)이 기포탑 내부의 총괄 열전달 계수(h)에 미치는 영향을 규명하였다. 기포탑 내부 열원 표면과 기포탑 벌크영역 간의 온도차는 시간의 변화에 따른 온도차 요동을 측정하여 그 평균값으로 결정하였다. 기포탑 내부 열원표면과 기포탑 벌크 영역 간의 온도차 요동은 연속 액상의 표면장력이 감소할수록 진폭이 감소하였으며 온도차의 평균값도 감소하였다. 내부 수직 열원과 기포탑 간의 총괄 열전달 계수는 기체의 유속과 슬러리 상에 포함된 고체입자의 분율이 증가함에 따라 증가하였으며 연속 액상의 표면장력이 증가함에 따라 감소하였다. 표면장력이 물보다 작은 연속 액상의 기포탑에서 측정된 총괄 열전달 계수는 본 연구의 범위 내에서 실험변수와 무차원군의 상관식으로 나타낼 수 있었다.

액상 판형열교환기 성능실험장비 및 설계프로그램 개발 (Development of Performance Test Apparatus and Design Program of Liquid-Phase Plate Heat Exchanger)

  • 박상일;송영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1306-1311
    • /
    • 2004
  • The performance test apparatus of liquid-phase plate heat exchanger was installed and the computer program for design was developed in this study. The detail temperature distribution of hot and cold fluids in each path of heat exchanger was calculated by numerical method and the correlation for the heat transfer coefficient was defined. The heat transfer coefficients were measured using the working fluids of water and glycerine to investigate the effect of fluid viscosity. The measured heat transfer coefficients were compared with the calculated values obtained from the computer program and it was shown that error of the calculated values was generally less than 5%.

  • PDF

FEM을 이용한 용접부의 열전달 및 잔류응력 해석 (Analysis of Meat transfer and Residual Stress on the Weld Zone Using FEM)

  • 김일수;박창언;김학형;정영재
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1999년도 특별강연 및 추계학술발표대회 개요집
    • /
    • pp.310-313
    • /
    • 1999
  • This paper represents to develop a computer software system which is capable to analyze the phase transformation of high strength steel(BV-AH32) and to predict heat transfer, residual stress due to phase transformation during Gas Metal Arc(GMA) welding. The developed model was taken into account temperature dependent of young's modules, coefficient of thermal expansion and yield stress as well as the double ellipsoidal heat distribution by the moving arc. The results showed that the longitudinal and transverse residual stresses calculated by the coupled analysis of heat transfer, residual stress and phase transformation are in good agreement with the experimental data. In addition, the temperature distribution as well as longitudinal and transverse residual stresses of weldment were determined at the 1-pass and 2-pass of welding.

  • PDF

두 개의 송신코일을 갖는 위상 천이 자기 공진 무선 전력 전송 시스템 (Phase Shifted Magnetic Resonance Wireless Power Transfer System with Two Transmit Coils)

  • 정재엽;이강현
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.290-293
    • /
    • 2018
  • This paper proposes a new magnetic resonant wireless power transfer system. Two transmitters are arranged to secure a range wider than the existing one-to-one resonance, thereby enhancing the practicality of the system. Two identical transmission units are arranged to strengthen the magnetic field and to subsequently increase the magnitude and distance of the power transmitted to the reception unit. A constant power can be maintained in a wide range through the phase control of different output powers according to the positions of the transmitting and receiving coils. A constant power can also be obtained by transmitting to the receiver. The experiment results show that the proposed method outperforms the conventional method.