• Title/Summary/Keyword: Phase sensitive method

Search Result 385, Processing Time 0.025 seconds

A study on simultaneous determination of residual sulfonamides in livestock productions by high performance liquid chromatography (HPLC를 이용한 축산식품중 잔류 설폰아미드제의 동시분석법 연구)

  • 황래홍;김영수;윤은선;김기근;이규학
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.3
    • /
    • pp.13-28
    • /
    • 1995
  • This study was carried out to explore the most sensitive and useful method for simultaneous determination of five sulfa drugs(sulfamethazine, sulfamerazine, sulfamonomethoxine, sulfadimethoxine, sulfaquinoxaline) in livestock productions(pork muscle, bovine muscle, chicken muscle, milk ) by HPLC with UV detector and reverse phase column. The results obtained were as follows:1. For mobile phase acetonitrile-0.01M ammonium acetate (23:77) showed more applicable sensitivity and retention times than acetonitrile-1% acetic acid(23:77). Thus acetonitrile-0.01M ammonium acetate(23:77) selected and applied to the modification test, from which it was found pH 6.75 was the most adequate. 2. Optimal wavelength of UV for SMT(sulfamethazine), SMR(sulfamerazine), SMM(sulfamonomethoxine), SD(sulfadimethoxine), and SQ(sulfaquinoxaline) were 266, 266, 265, 269 and 250nm, respectively, and that for simultaneous application it was 263nm. 3. The average recovery rate by extractant(chloroform, dichloromethane, chlorform+dich-loromethane) in the classic method was not significantly different(p>0.05) but that by chloroform higher than the others. Thus chloroform was found to be adequate as extractant in this classic method. 4. The average recovery rate was 86.5% by the MSPD(matrix solid phase disperse) method, which was significantly higher than that by the classic method(p<0.05). Also the recovery rates by method were significantly different(p<0.05) in accordance with sample and type of drug. The MSPD method was much superior to classic method on clean-up.

  • PDF

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A Novel Phase Extraction for the Detection of Time Parameters in Signal

  • Lee Eun-bang
    • Journal of Navigation and Port Research
    • /
    • v.29 no.4
    • /
    • pp.341-347
    • /
    • 2005
  • A unique technique to extract the phase in time domain is proposed in order to measure the time parameters such as speed and depth by transmitting sound and electric waves. In the signal analysis processing, the phase of pulse signal can be transformed and digitalized with local data in real time without the effect of direct current bias and Nyquist limits. This method is sensitive to base frequency of pulse signal with high spacial resolution and is effective to compare two signals which have different forms. It is expected that the phase analysis technique will be applied to the measurement of the speed and depth accurately by ultrasonic pulse signal in water.

Joint Estimation of Near-Field Source Parameters and Array Response

  • Cui, Han;Peng, Wenjuan
    • Journal of Information Processing Systems
    • /
    • v.13 no.1
    • /
    • pp.83-94
    • /
    • 2017
  • Near-field source localization algorithms are very sensitive to sensor gain/phase response errors, and so it is important to calibrate the errors. We took into consideration the uniform linear array and are proposing a blind calibration algorithm that can estimate the directions-of-arrival and range parameters of incident signals and sensor gain/phase responses jointly, without the need for any reference source. They are estimated separately by using an iterative approach, but without the need for good initial guesses. The ambiguities in the estimations of 2-D electric angles and sensor gain/phase responses are also analyzed in this paper. We show that the ambiguities can be remedied by assuming that two sensor phase responses of the array have been previously calibrated. The behavior of the proposed method is illustrated through simulation experiments. The simulation results show that the convergent rate is fast and that the convergent precision is high.

New Analytical Method of Cyclosporine A in Human Serum by High -performance Liquid Chromatography/Diode Array Detector and Its Application to Pharmacokinetics of Cyclosporine A in Human Volunteers

  • Kim, Eun-Young;Chung, Yeon-Bok;Kwon, Oh-Seung
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.423.1-423.1
    • /
    • 2002
  • A simple. specific and sensitive method for the determination of cyclosporine A (CsA) in human serum has been developed by a high performance liquid chromatography/diode array detector (DAD) and applied to pharmacokinetic study of CsA. This method involves the use of solid phase extraction procedure following rapid protein precipitation with zinc sulphate from 1 $m\ell$ of human serum, using a disposable $C_{18}$ extraction cartridge. (omitted)

  • PDF

Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe (사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발)

  • Lee, Kyoung-Hwang;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

Novel pH/Temperature Sensitive Hydrogels of Poly (ethylene glycol)-Poly (caprolactone) -Poly (${\beta}-amino\;ester$) (PAE-PCLA-PEGPCLA-PAE) Biodegradable Polyester Block Copolymer

  • Huynh Dai Phu;Lee Doo-Sung
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.263-263
    • /
    • 2006
  • Poly (ethylene glycol)(PEG) - Poly (${\varepsilon}-caprolactone(CL)$) - Poly (D,L lactide(LA) (PCLA-PEG-PCLA) was synthesized by ring-opening polymerization to form temperature sensitive hydrogel triblock copolymer. The triblock copolymer was acrylated by acryloyl chloride. ${\beta}-amino$ ester was used as a pH sensitive moiety, in this study ${\beta}$- amino ester obtained from 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine, it have pKb around 6.6. pH/temperature sensitive penta-block copolymer (PAE-PCL-PEG-PCL-PAE) was synthesized by addition polymerization from acrylated triblock copolymer, 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine. Their physicochemical properties of triblock and penta-block copolymers were characterized by $^1H-NMR$ spectroscopy and gel permeation spectroscopy. Sol-gel phase transition behavior of PAE-PCL-PEG-PCL-PAE block copolymers were investigated by remains stable method. Aqueous media of the penta-block copolymer (at 20 wt%) changed from a sol phase at pH 6.4 and $10^{\circ}C$ to a gel phase at pH 7.4 and $37^{\circ}C$. The sol-gel transition properties of these block copolymers are influenced by the hydrophobic/hydrophilic balance of the copolymers, block length, hydrophobicity, stereo-regularity of the hydrophobic of the block copolymer, and the ionization of the pH function groups in the copolymer depended on the changing of environmental pH, respectively. The degradation and the stabilization at pH 7.4 and $37^{\circ}C$, and the stabilization at pH 6.4 and $10^{\circ}C,\;5^{\circ}C,\;0^{\circ}C$, of the gel were determined. The results of toxicity experiment show that the penta block copolymer can be used for injection drug delivery system. The sol?gel transition of this block copolymer also study by in vitro test ($200{\mu}l$ aqueous solution at 20wt% polymer was injected to mouse). Insulin loading and releasing by in vitro test was investigated, the results showed that insulin can loading easily into polymer matrix and release time is around 14-16days. The PAE-PCL-PEG-PCL-PAE can be used as biomaterial for drug, protein, gene loading and delivery.

  • PDF

Assay of Midazolam in Human Plasma by Gas-Liquid Chromatography with Nitrogen-Phosphorus Detection

  • 신호상;홍춘표;Yun-Suk Oh-Shin;강보경;이경옥;이규범
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.5
    • /
    • pp.524-526
    • /
    • 1998
  • A sensitive and specific method is described for the determination of midazolam in human plasma. The drug was extracted from 1 mL of carbonate buffered plasma (pH 9.6) with 8 mL of diethyl ether. Famprofazone was used as internal standard. The organic phase was evaporated to dryness. The residue was dissolved in methanol for the direct analysis by gas chromatograph-nitrogen phosphorus detector system. In the concentration range of 1-5000 ng/mL, the calibration curve was linear. The coefficients of variation from the precision test were <6% at the range of the concentration of 0.10-2.00 μg/mL and the detection limit for midazolam in 1 mL of plasma was o.5 ng. This assay is more sensitive, selective, simple and rapid than earlier methods. Plasma midazolam concentrations were determined by this method after administration of midazolam.

A Rapid Preconcentration Method Using Modified GP-MSE for Sensitive Determination of Trace Semivolatile Organic Pollutants in the Gas Phase of Ambient Air

  • He, Miao;Xu, Qingjuan;Yang, Cui;Piao, Xiangfan;Kannan, Narayanan;Li, Donghao
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2995-3000
    • /
    • 2014
  • A sensitive concentration method utilising modified gas-purge microsyringe extraction (GP-MSE) was developed. Concentration (reduction in volume) to a microlitre volume was achieved. PAHs were utilised as semivolatile analytes to optimise the various parameters that affect the concentration efficiency. The injection rate and temperature were the key factors that affected the concentration efficiency. An efficient concentration (75.0-96.1%) of PAHs was obtained under the optimised conditions. The method exhibited good reproducibility (RSD values that ranged from 1.5 to 9.0%). The GP-MSE concentration method enhances the volume reduction (concentration factor), leading to a low method detection limit ($0.5-15ngL^{-1}$). Furthermore, this method offers the advantage of small-volume sampling, enabling even the detection of diurnal hourly changes in the concentration of PAHs in ambient air. Utilising this method in combination with GC-MS, the diurnal hourly flux of PAHs from the gas phase of ambient air was measured. Indeed, the proposed technique is a simple, fast, low-cost and environmentally friendly.

Studies on the development of enzyme linked immuno-sorbent assay (ELISA) for hepatitis B surface antigen (HBsAg) by monoclonal antibodies of different affinity constants

  • Kim, Gye-Won;Hong, Sung-Youl;Shin, Soon-Cheon;Lee, Sung-Hee;Kim, Won-Bae
    • Archives of Pharmacal Research
    • /
    • v.10 no.1
    • /
    • pp.18-24
    • /
    • 1987
  • Mouse monocolonal antibodies to Hepatitis B surface antien (HBsAg) were prepared and their functional capabilities tested by the method of solid phase enzyme linked immuno sorbent assay (ELISA). HBsAg binding studies inicated that one monoclonal antibody 6E-1-1 bound more HBsAg at a faster rate than the other monoclonal antibodies. Also, for the binding inhibition studies with the selected monoclonal antibody 6E-1-1, one monoclonal antibody 8D-3-6 didn't exhibit binding inhibition for HBsAg. Then, a simultaneous ELISA method was developed for the immunodiagnosis of HBsAg. Different combinations of two monoclonal antibodies as solid phase and horseradish peroxidase (HRPO) labeled phase were studied. The combination of monoclonal antibody of higher affinity constant (6E-1-1) immobilized in a solid phase and monoclonal antibody of lower affinity constant (8D-3-6) as a HRPO laeled phase was more sensitive when two monoclonal antibodies of different affinity constants for HBsAg were prepared.

  • PDF