A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.
본 논문에서는 차세대 디지털 TV 및 무선 랜 등과 같이 고속에서 저전압, 저전력 및 소면적을 동시에 요구하는 고성능 집적시스템을 위한 10b 250MS/s
목적 : 고식적인 자기공명혈관조영술 (MR Angiography, MRA) 기법으로는 영상화가 어려웠던 대동맥궁의 주요 분지들의 평가에 있어서 새로운 MR기법인 조영증강 MRA의 임상적 유용성을 알아보고, 그 화질을 사용한 코일의 종류에 따라 비교해 보고자 한다. 대상 및 방법 : 뇌혈관 질환을 의심하여 고식적인 기법으로 뇌 및 경동맥 MRA를 시행한 29명에서 전향적으로 Gd-DAPA 15-20ml를 일시에 손으로 주입한 후 대동맥궁과 그의 주요 분지들에 대해 3시기의 고속 MRA를 시행하여 그 화질을 분석하였다. MRA는 1.0T MR기종에서 3D-FISP기법으로 얻었으며 총 영상 획득 시간은 40-60초였다. 영상 분석은 무명동맥, 양측 총경동맥, 양측 쇄골하동맥과 양측 척추 동맥들의 기시부로부터 전장에 걸쳐 화질을 주관적으로 3등급(good; 명백히 정상소견을 보이는 경우, fair; 약간 낮은 신호를 보이나 정상으로 진단하기에 비교적 만족할 만한 경우, poor; 협착이 모호하거나, 인공물이나 너무 낮은 신호로 혈관을 볼 수 없어 카테터 혈관조영술을 요하는 경우)으로 나누어 평가하였으며, 양측 총경동맥의 분기(bifurcation) 부위에서는 고식적인 기법의 영상과 그 화질을 비교평가하였다. 또한 세가지 사용한 코일의 종류(CP body array 12예, CP neck array 9예, head-and-neck 8예)에 따른 화질 차이를 정성적 및 정량적(신호대 잡음비)으로 분석하였다. 결과 : 대동맥궁 주요 분지들의 전반적인 화질은 55% (16/29)에서 'good', 34%(10/29)에서 'fair'로 평가되어 대부분 고식적인 카테터 혈과조영술이 피요치 않을 정도로 만족할 만한 화질을 보였다. 양측 총경 동맥분지 부위에서는 65%(17/26)에서 고식적인 3D-TOF기법과 같거나 나은 영상을 보였다. CP body array 코일을 사용한 경우가 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 정성적 및 정량적으로 유의하게 나은 영상을 보였다(p<0.05). 결론 : 고속 조영증강 MRA기법은 단시간내 (40-60초)에 대동맥구의 주요 분지들을 그 기시부위부터 두개골 저부에 이르기까지 대부분에서 잘 나타내주므로 선별검사로서 임상적으로 유용하리라 생각되며 CP body array 코일을 사용하였을 경우에 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 좀더 나은 화질을 얻을 수 있으리라 생각된다.
The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.
공동충전 효과를 검증하기 위하여 실시한 시차 공대공 탄성파 탐사자료로부터 지하공동 부존 지역에서 충전 전과 후에 매질의 탄성파 전파속도의 변화를 확인하였다. 시차 공대공 탄성파 탐사자료에 나타난 반응과 시추조사 결과에 의하면 본 지역의 공동은 규모가 극히 소규모이거나 또는 폐석 등으로 충전된 것으로 보인다. 공동충진 효과는 토모그래피로부터 도출된 속도단면상의 탄성파 속도의 증가량을 분석함으로써 평가하였다. 시추공용 에어건을 진원으로 24-채널 하이드로폰을 수진기로 하여 자료를 취득하였다. 취득한 자료에는 무시할 수 없을 정도의 source statics를 확인할 수 있었다. 본 논문에서 제시한 보정방법은 2단계로; 1) 불규칙한 발파시점에 의한 영향 보정과 2) 잔여 정보정으로 이는 진원의 부정확한 위치에 대한 정보정이다. 본 논문에서는 고주파수 성분의 수치잡음이 억제되고 관심대상 부분에서 비교적 고분해능 영상을 도출할 수 있는 다단계 역산 방안을 제시하였다. 일반적으로 최소자승 주시토모그래피로는 평활화된 속도 영상을 얻을 수 있다. 따라서 이러한 역산으로는 비교적 소규모의 구간에서 발생한 적은 속도변화를 영상화하기에는 어려운 면이 있다. 본 논문에서는 속도모델의 파라메터를 변화시킨 2단계 제어 역산법으로 도출한 시차 토모그램으로부터 채굴 영향대에서 발생한 매질의 속도변화를 시각화 할 수 있었다. 2단계 역산법은 1-단계에서는 적정한 크기의 균일 격자로 구성된 모델을 사용하여 토모그램을 작성하고 이 토모그램에 2차원 중위수 필터를 적용하여 대략적인 속도구조 모델을 작성한다. 2-단계 역산시는 1-단계에서 작성한 속도모델을 수정하여 초기 모델로 한다. 모델 수정은 관심대상 부분만을 작은 크기의 균일격자로 재구성하는 것이다. 기준조사 토모그램을 2차 조사자료 역산의 초기 속도모델로 사용하였다. 속도변화는 공동대 부근에서만 예상되므로 그 이외 부분의 속도는 기준 토모그램과 동일하게 고정시키고 역산을 수행하였다.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
인구의 고령화와 함께 골다공증성 척추압박골절 환자의 발병률은 매년 증가하는 추세이며 경피적 척추성형(percutaneous vertebroplasty, PVP)은 가장 많이 시행되는 표준화된 치료 방법이다. 시술 전 후의 정확한 진단평가에 있어 SPECT/CT 검사의 유용성이 우수하다는 연구 보고가 있으나 시술에 사용되는 골 시멘트(bone cement) 물질은 CT 영상에서 인공물(artifact)을 생성하여 영상품질에 영향을 미친다. 이에 본 연구에서는 골 시멘트가 SPECT/CT 영상에 미치는 영향을 평가하는 데 목적을 두었다. NEMA-1994 팬텀(phantom)에 배후방사능(3.6 kBq/ml), 열소(29.6 kBq/ml), 냉소(물)를 설정한 후 각 원통(cylinder)에 모형 시멘트를 삽입하여 영상 획득하였다. Astonish (Iterative: 4, Subset: 16)으로 재구성하였고, CT 보정 방법은 비감쇠보정(NAC), 감쇠보정(AC+SC-), 감쇠 및 산란보정(AC+SC+) 3가지 방법을 사용하였다. 각각의 보정방법에 따른 평균계수와 시멘트물질의 유 무에 따른 계수 변화율을 비교하고 대조도 회복 계수(contrast recovery coefficient, CRC)를 구했다. 또한, 압박골절 진단을 받은 환자 107명 중 PVP를 시행한 20명을 선별하여 추체를 골절, 정상, 시멘트로 나누고 연조직(척추기립근)을 포함 4곳의 평균 계수를 측정한 후, 뼈/연조직 간 계수 비(bone/soft tissue ratio, B/S ratio)을 구했다. NAC를 기준으로 AC+SC-, AC+SC+의 평균계수는 증가하였고, AC+SC-의 평균계수가 가장 높았으며, AC+SC+는 AC+SC-에 비해 상대적으로 낮았다. 시멘트 물질의 유 무에 따른 평균계수는 시멘트가 존재할 때 NAC, AC+SC-, AC+SC+에 따라 팬텀의 열소에서 12.4%, 6.5%, 1.5%, 냉소 75.2%, 85.4%, 102.9%, 배후방사능 13.6%, 18.2%, 9.1%, 임상영상의 골절부에서 33.1%, 41.4%, 63.5%, 정상부 53.1%, 61.6%, 67.7%, 연조직 10.0%, 4.7%, 3.6%의 증가율을 보였다. 반면 원통 내부의 시멘트 인접부에서 상대적 계수감소를 확인할 수 있었고, 병소에 대한 팬텀영상과 임상영상간의 계수 증가율은 상반된 양상을 보였다. 대조도 비를 나타내는 CRC와 B/S ratio는 NAC, AC+SC-, AC+SC+순으로 향상되었고, 팬텀의 냉소에서는 큰 변화 없이 일정하였다. 정량적 계수는 AC+SC-가, 대조도 비는 AC+SC+가 가장 높게 분석되었다. PVP 시행 환자의 척추 뼈 SPECT/CT 검사에서 AC+SC- 의 사용은 영상계수를 대폭 향상시켜 특히 병소의 농도가 높은 영상을 얻는 반면에 골 시멘트의 영향과 함께, 연부조직 및 산란영역의 영상잡음 계수까지 증가시키므로 대조도비를 향상시키는 AC+SC+의 적용을 병행한다면 임상진단에 유용할 것으로 사료된다.