• Title/Summary/Keyword: Phase extraction

Search Result 1,423, Processing Time 0.022 seconds

A Study on the Analytical Methods Using Solid-phase Extraction for the Determination of Phenols in Water

  • Jeon, Chi-Wan;Lee, Jung-Hwa;Lee, Sang-Hak
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.135-138
    • /
    • 2003
  • Based on solid phase extraction, gas chromatography and mass spectrometry procedure for determining phenol and its derivatives in natural water was presented. In solid phase extraction, three types of techniques using solid phase adsorption material were treated with acid and salt, and converted second portion of acetyl derivatives. Under the these condition, extraction efficiency and detection ability dependent on extraction methods were discussed. Obtained results using optimized solid phase extraction techniques showed more convenience, simplifier and lower cost than the conventional analytical methods with holding wide dynamic range and lower detection limits.

  • PDF

Extraction and separation of glabridin from licorice by reversed phase high performance liquid chromatography

  • Choi, Du Young;Row, Kyung Ho
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.455-459
    • /
    • 2006
  • The extraction and separation of glabridin from licorice root by HPLC was performed in this work. First, by investigating the different extraction solvents, extraction methods and extraction times, a one-hour ultrasonic extraction procedure with ethyl acetate as the extraction solvent was optimized. Then the ethyl acetate extraction was applied to RP-HPLC for separation of glabridin. The column efficiencies and resolutions were experimentally investigated with different mobile phase compositions. Baseline separation of glabridin was obtained under the mobile phase composition of 50/50 vol.% (ACN/water). The retention time of glabridin was 20.3 min. The peak of glabridin was collected from the HPLC elution for several times and identified by LC/MS. Under the optimum extraction and HPLC separation methods, 1.26 g of glabridin per kg licorice root could be extracted.

Extraction of Chromium (Vl) Son in Waste Water through the Liquid Surfactant Membrane with Open-Type Perforated Reciprocating-Plate Column (개방형 왕복 다공판 추출탑을 이용한 액막법에 의한 폐수중 Cr(Vl)의 추출)

  • 우인성;강현춘;안형환
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.2
    • /
    • pp.44-50
    • /
    • 1993
  • The objective of this study was to investigate the extraction of chromium(Vl) ion in waste water through the liquid surfactant membrane with open-type Perforated Reciprocating-Plate Column. Extraction experiments were conducted to measure the effect of flow characteristics of continuous and dispersed phase and stroke velocity, sodium hydroxide concentraction in internal aqueous phase, sulfuric acid concentraction in outer phase, and residence time distribution and measured extraction velocity. The result of experiments showed that extraction velocity of chromium ion was maximum when stroke velocity was 180 1/min and dispersion phase velocity was 30m11min, continuous phase velocity was 20m1/min. Extraction velocity of chromium ion increased with increasing difference of hydrogen ion concentraction of dispersion and continuous phase and column stage decreased.

  • PDF

Solid-Phase Extraction of Caffeine and Catechin Compounds from Green Tea by Caffeine Molecular Imprinted Polymer

  • Jin, Yinzhe;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.276-280
    • /
    • 2007
  • In this work, caffeine and some catechin compounds + C, EC, EGC, and EGCG were extracted from green tea by using molecular imprinted polymers (MIP) as sorbent materials in a solid-phase extraction (SPE) process known as MISPE (molecular imprinted solid-phase extraction). For synthesis of MIP, caffeine was employed as the template, MAA as the monomer, EGDMA as the crosslinker, and AIBN as the initiator. A solution of caffeine (0.2 mg/mL in methanol) was utilized in the solid extraction cartridges following loading, washing, and elution procedures with acetonitrile, methanol, and methanol-acetic acid (90/10, %v/v) as the solvents, respectively. This solid-phase extraction protocol was applied for the extraction of caffeine and some catechin compounds from green tea. A comparison was made between the results obtained with the MIP cartridges and a traditional C18 reversed-phase cartridge. It was thereupon found that the recovery of caffeine by the MIPbased sorbent used in this work was almost two and four times greater than that by a commercially available C18 material. A quantitative analysis was conducted by high performance liquid chromatography (HPLC) using a C18 column (5 μm, 250 × 4.6 mm) with methanol/water (40/60, %v/v) as the mobile phase at a flow rate of 0.5 mL/min.

Improvement of Hydrocarbon Recovery by Two-Stage Cell-Recycle Extraction in the Cultivation of Botryococcus braunii

  • An, Jin-Young;Sim, Sang-Jun;Kim, Byung-Woo;Lee, Jin-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.932-937
    • /
    • 2004
  • In situ extraction by organic solvent was studied in order to improve the recovery yield of hydrocarbon from the culture of Botryococcus braunii, a green colonial microalga. When the solvent mixture of octanol as an extractive solvent and n-octane as a biocompatible solvent was added to a two-phase column, the algal growth was seriously inhibited, even at a low concentration of polar octanol. Therefore, a two-stage cell-recycle extraction process was proposed to improve the contact area between the organic phase and the aqueous phase. The hydrocarbon recovery with in situ cell-recycle extraction showed a three-fold increase (57% of cell) in yield over that with two-phase extraction. In addition, over 60% of the hydrocarbon could be recovered without serious cell damage by downstream separation when this process was applied to the culture broth after batch fermentation.

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

Separation of Lactoferrin from Model Whey Protein Mixture by Reverse Micelles Formed by Cationic Surfactant

  • Noh, Kyung-Hyun;Rhee, Min-Suk;Imm, Jee-Young
    • Food Science and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.131-136
    • /
    • 2005
  • The selective extraction behavior of lactoferrin (Lf) from whey protein mixture was examined using reverse micelles formed by the cationic surfactant, cetyldimethylammonium bromide (CDAB). The major whey proteins, including ${\beta}$-lactoglobulin, ${\alpha}$-lactalbumin and bovine serum albumin, were solubilized from aqueous phase to organic phase while Lf was recovered in the aqueous phase. The solubilization behaviors of the proteins were manipulated by the process parameters such as the pH and salt concentration of the aqueous phase and the surfactant concentration in the organic phase. Efficient forward extraction was achieved with sodium borate buffer (50 mM, pH 9) containing 50 mM KCl and organic phase containing 100 mM CDAB. Based on SDS-PAGE and densitometry, about 96% of the initial Lf remained in the aqueous phase after forward extraction. The dialyzed Lf fully maintained its bacteriostatic activity against E. coli O157:H7.

Multisample Extraction system for Solid Phase Extraction of Dissolved Organic Compounds from Sea Water (해수로부터 용존 윤기물의 Solid Phase Extraction을 위한 다수 시료 처리 장치)

  • Cho Ki Woong;Jung Kyungwha;Shin Jongheon;Kim Suk Hyun;Hong Gi-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.34-40
    • /
    • 2000
  • A multisample extraction device was newly designed for efficient extraction of dissolved lipophillic organic compounds from sea water sample. This device allowed extraction of organic compounds from up to 96 sample at a time using 96 multifolder on the principle of solid phase extraction with commercially available octadecyl silane (ODS) cartridges. The recovery yield of the new divice was higher than 90 % while that of conventional liquid-liquid extraction process are only 60 - 70 %. The amount of solvent required for the new device could be reduced to less than 20㎖ per 1ℓ of sample while 1 - 2 ℓ of solvent were used in the conventional liquid-liquid extraction process. The usefulness of this novel method was demonstrated with sea water samples collected from Yellow sea, and the qualitative and quantitative analyses results of the dissolved hydrocarbon showed this method was superior to that of conventional liquid-liquid extraction process in efficiency and reliability.

  • PDF

Solid-Phase Extraction of Curcuminoid from Turmeric Using Physical Process Method (물리적 가공법을 이용한 강황으로부터 Curcuminoid의 고체상추출)

  • Lee, Kwang-Jin;Yang, Hye-Jin;Jeong, Sang-Won;Ma, Jin-Yeul
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.3
    • /
    • pp.250-256
    • /
    • 2012
  • In order to extract the curcuminoid such as curcumin, demethoxycurcumin (DMC), and bisdemethoxycurcumin (BDMC) in turmeric (Curcuma longa), solvent extraction methods (dipping and ultrasonic extraction method) and solid-phase extraction (SPE) were used. RP-HPLC (reverse-phase high-performance liquid chromatography) and TLC (thin-layer chromatography) were used for identification and analysis the three curcuminoid. From the experimental results, it is evident that the percentage of curcuminoid extracted from turmeric by ultrasonic extraction method was higher than dipping method. The percentage of curcumin extracted from turmeric by pure methanol was higher than any aqueous methanolic composition. Moreover, the total peak area of three curcuminoid was above 92% in RP-HPLC using solid-phase extraction. These results will form a database for investigating the constituents of natural products and the resources of pharmaceutical, nutrition, and cosmetic products.