• Title/Summary/Keyword: Phase delay compensation

Search Result 91, Processing Time 0.022 seconds

Analysis of the Admittance Component for Digitally Controlled Single-Phase Bridgeless PFC Converter

  • Cho, Younghoon;Mok, Hyungsoo;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.600-608
    • /
    • 2013
  • This paper analyzes the effect of the admittance component for the digitally controlled single-phase bridgeless power factor correction (PFC) converter. To do this, it is shown how the digital delay effects such as the digital pulse-width modulation (DPWM) and the computation delays restrict the bandwidth of the converter. After that, the admittance effect of the entire digital control system is analyzed when the bridgeless PFC converter which has the limited bandwidth is connected to the grid. From this, the waveform distortion of the input current is explained and the compensation method for the admittance component is suggested to improve the quality of the input current. Both the simulations and the experiments are performed to verify the analyses taken in this paper for the 1 kW bridgeless PFC converter prototype.

영구자석형 동기 전동기의 토크 특성 개선에 관한 연구 (A Study on the Improvement of Torque Characteristics in PM Synchronous Motor)

  • 류시영;이두수
    • 전력전자학회논문지
    • /
    • 제6권3호
    • /
    • pp.231-242
    • /
    • 2001
  • 본 논문에서는 영구자석형 동기 전동기 고정자의 상 권선 인덕턴스에 의하여 지연되는 정현과 서류 지연 성분을 보상함으로써 전동기 발생 토크 특성을 개선하는 방법과 구현 방법을 제시하였다. 이 방법은 축 변환을 사용하지 않기 때문에 하드와이어드 로직에 의하여 구현함으로써 구현이 간단하고 축 변환에 의한 지연을 제거할 수 있다. 특히, 고정자 상 권선 인덕턴스에 의한 지연성분은 전동기 회전 속도에 따라 변화하며, 본 논문에서 제시한 방법을 이용하면 전동기 회전 속도에 따른 동적인 보상을 할 수 있다. 존 논문에서 제시한 방법의 효과를 입증하기 위하여 4극 3상 영구자석형 동기 전동기를 대상으로 실험을 행하였으며, 실험결과 모든 운전 속도에서 발생 토크가 증가함을 확인하였다.

  • PDF

자동차 전동 시스템을 위한 Programmable 저역 통과 필터 기반의 상전류 극성 판단 및 데드타임 보상 (Dead Time Compensation and Polarity Check of Phase Currents Based on Programmable Low-pass Filter for Automotive Electric Drive Systems)

  • 최진철;이강석;이우택
    • 한국자동차공학회논문집
    • /
    • 제22권6호
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a dead time compensation method for an AC motor drive using phase current polarity information which is detected based on a digital programmable low-pass filter (PLPF). The polarity detection using the PLPF is an alternative solution of a conventional method which uses a general low-pass filter (LPF) and hysteresis bands in order to avoid jittering due to noises. The PLPF not only adjusts its cutoff frequency according to the synchronous frequency of AC motors but also eliminates a gain attenuation and phase delay which are main problems of the general LPF. Through the PLPF, a fundamental component signal without gain and phase distortions is extracted from the measured raw current signal with noise. By use of the fundamental component, the polarity of current is effectively detected by reducing the hysteresis band. Finally, the proposed method compensates the dead time effects by adding or subtracting average voltage value to voltage references of the controller according to the detected current polarity information. The proposed compensation method is experimentally verified by compared with the conventional method.

단일 전류 센서를 사용한 3상 전압형 PWM 컨버터의 제어 방식 비교 (Comparison of Three-Phase Voltage-Source PWM Converters Using a Single Current Sensor)

  • 이우철;이택기;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권4호
    • /
    • pp.188-200
    • /
    • 2001
  • This paper presents a technique for reconstructing converter line currents using the information from a single current sensor in the DC-link for voltage-source PWM converters. When three-Phase input currents cannot be reconstructed, three methods to acquire the input current are compared. Two of them are methods of modifying the switching state (I, II), another is a method of using the predictive state observer. Also, compensation of sampling delay, and a simultaneous sample value of input currents in the center of a switching period are included. Suitable criteria for the comparison are identified, and the differences in the performance of these methods are investigated through experimental results for a typical V-S PWM converter rated at 10kVA.

  • PDF

단상 PV 인버터용 온라인 데드타임 보상기 연구 (A New On-Line Dead-Time Compensator for Single-Phase PV Inverter)

  • 부우충기엔;이상회;차한주
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.409-415
    • /
    • 2012
  • This paper presents a new software-based on-line dead-time compensation technique for a single-phase grid-connected photovoltaic (PV) inverter system. To prevent a short circuit in the inverter arms, a switching delay time must be inserted in the pulse width modulation (PWM) signals. This causes the dead-time effect, which degrades the system performance around zero-crossing point of the output current. To reduce the dead-time effect around the zero-crossing point of grid current, a harmonic mitigation of grid current is used as an additional part of the synchronous frame current control scheme. This additional task mitigates the harmonic components caused by the dead-time from the grid current. Simulation and experimental results are shown to verify the effectiveness of the proposed dead-time compensation method in the single-phase grid-connected inverter system.

고속의 주파수 계측 알고리즘을 갖는 저주파 계전기 설계 (The Design of UFR with Fast Frequency Measurement Technique)

  • 박종찬;김병진
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.1-5
    • /
    • 2006
  • In this paper, the frequency estimator and DFT filter gain compensation for UFR(Under Frequency protection Relay) is introduced. Due to the sudden appearance of generator loads or faults in power system, the frequency is supposed to deviate from its nominal value. Because a frequency calculation is based on phase information, it needs sufficient sampling data to figure out a precious frequency. Therefore the frequency measurement for UFR needs excellent qualities such as high speed and precision with low sampling frequency Authors propose the frequency estimator which compares the vector differences and the DFT filter gain compensation which identifies DFT filter error and correct it. Using the frequency estimator and compensation, UFR which has the 0.01[ms] calculation delay and 0.003[Hz] measurement error is implemented with digital processor.

PQR 순시전력이론에 의한 동적전압보상기의 보상전압 결정 (Determining the Compensation Voltages for Dynamic Voltage Restorers by use of PQR Instantaneous Power Theory)

  • 김효성;이상준;설승기
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.442-449
    • /
    • 2003
  • 본 논문은 PQR 순시전력 이론을 이용하여 순시전압보상장치 (DVR)에서 기준보상전압을 결정하는 방법을 제시한다. 측정된 3상 단자 전압은 시간지연 없이 PQR 좌표계로 변환된다. PQR 좌표계의 기준전압은 단일한 직류값이므로 DVR의 전압제어기는 단순하고 쉽게 설계가 가능해 진다. 제안된 제어방식은 피드백 제어기나 피드포워드 제어기에 모두 적용될 수 있다. 본 논문에서는 피드포워드 제어기에 대하여 이론을 적용하였으며 실험 및 시뮬레이션으로 검증을 하였다.

위상지연판 접합 편광필름의 광학적 고찰 및 결함 검출 방안 (Optical Investigation and Defect Detection Methods in Polarizing Film on Phase Delay Plates)

  • 주영복;허경무
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.55-61
    • /
    • 2021
  • In this paper, we proposed and implemented defect detection methods of polarized film with half-wave phase retardation plates. We investigated the principles of phase retardation compensation and optical principle of half-wave phase retardation plates. We analyzed of samples of polarized film with half-wave phase retardation plates. The optical defect detection methods are proposed and the performance is validated with experiments.

단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계 (The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation)

  • 김승민;양승대;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF

계통전압 왜곡 및 불평형시 3상 계통연계인버터의 계통전류제어 기법 (Grid Current Control Scheme at Thee-Phase Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions)

  • ;전태원
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1560-1565
    • /
    • 2013
  • This paper proposes the control method for compensating for unbalanced grid current and reducing a total harmonic distortion (THD) of the grid current at the three-phase grid-connected inverter systems under unbalancd and distorted grid voltage conditions. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for a minimum point of THD. Both the gain and angle of a compensation voltage at the minimum point of THD of the grid current are derived. The negative-sequence components in the three-phase unbalanced grid voltage are cancelled in order to achieve the balanced grid current. The simulation and experimental results show the validity of the proposed control methods.