• Title/Summary/Keyword: Phase control

Search Result 7,230, Processing Time 0.035 seconds

Phase Shift Control for Series Active Voltage Quality Regulators

  • Xiao, Guochun;Teng, Guofei;Chen, Beihai;Zhang, Jixu
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.664-676
    • /
    • 2012
  • A phase shift algorithm based on the closed-loop control of dc-link voltage implemented on a series active voltage quality regulator (AVQR) is proposed in this paper. To avoid pumping-up the dc-link voltage, a general phase shift compensation strategy is applied. The relationships among the operation variables are discussed in detail, which is very important for guiding the design of both the main circuit and the control system. Then on the basis of an investigation of the dc-link voltage pumping-up from viewpoint of the active power flow, a novel phase shift control method based on the closed-loop of the dc-link voltage is proposed. This method can adjust the phase of the output voltage gradually and automatically according to the dc-link voltage variation without introducing a phase jump. The effectiveness of the proposed strategy is verified through simulations of a single-phase 5kVA prototype and laboratory experiments on both a single-phase 5kVA and a three-phase 15kVA prototype.

Phase delay control of a cantilever beam using piezoelectric materials (압전체를 사용한 외팔보 진동의 위상지연 제어)

  • Hwang, Jin-Gwon;Choe, Jong-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.4
    • /
    • pp.343-349
    • /
    • 1997
  • In a lightly damped cantilever beam, most of the vibration energy is found around natural frequencies. Based on this, a phase delay control for suppressing vibration of the beam is proposed in this paper. This controller is designed to behave like a velocity feedback controller at the frequencies of modes to be controlled. Also, this controller is designed in consideration with uncontrolled modes for robust stability and improving of the sensitivity function of the control system. This phase delay control is applied to vibration suppression of a cantilever beam with a pair of a piezoelectric actuator and a piezoelectric sensor. Experimental results showed that the phase delay control functions efficiently.

  • PDF

MRAS Based Sensorless Control of a Series-Connected Five-Phase Two-Motor Drive System

  • Khan, M. Rizwan;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.224-234
    • /
    • 2008
  • Multi-phase machines can be used in variable speed drives. Their applications include electric ship propulsion, 'more-electric aircraft' and traction applications, electric vehicles, and hybrid electric vehicles. Multi-phase machines enable independent control of a few numbers of machines that are connected in series in a particular manner with their supply being fed from a single voltage source inverter(VSI). The idea was first implemented for a five-phase series-connected two-motor drive system, but is now applicable to any number of phases more than or equal to five-phase. The number of series-connected machines is a function of the phase number of VSI. Theoretical and simulation studies have already been reported for number of multi-phase multi-motor drive configurations of series-connection type. Variable speed induction motor drives without mechanical speed sensors at the motor shaft have the attractions of low cost and high reliability. To replace the sensor, information concerning the rotor speed is extracted from measured stator currents and voltages at motor terminals. Open-loop estimators or closed-loop observers are used for this purpose. They differ with respect to accuracy, robustness, and sensitivity against model parameter variations. This paper analyses operation of an MRAS estimator based sensorless control of a vector controlled series-connected two-motor five-phase drive system with current control in the stationary reference frame. Results, obtained with fixed-voltage, fixed-frequency supply, and hysteresis current control are presented for various operating conditions on the basis of simulation results. The purpose of this paper is to report the first ever simulation results on a sensorless control of a five-phase two-motor series-connected drive system. The operating principle is given followed by a description of the sensorless technique.

A Sensorless Speed Control of 2-Phase Asymmetric SRM with Parameter Compensator (파라미터 보상기를 가지는 비대칭 SRM의 센서리스 속도제어)

  • Lim, Geun-Min;Ahn, Jin-Woo;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.238-245
    • /
    • 2012
  • This paper presents a sensorless speed control of a 2-phase switch reluctance motor(SRM). The proposed sensorless control scheme is based on the slide mode observer with parameter compensator to improve the estimation performance. In the stand still position, the initial rotor position is determined by pulse current responses of each phase windings and the current difference. In order to determine an accurate initial rotor position, the two initial rotor positions are estimated by the difference of the pulse currents. From the stand still to the operating region, a simple open loop control which determines the commutation sequence by the pulse current of the unexcited phase winding is used. When the motor speed is reached to the sensorless control region, the estimated rotor position and speed by the slide mode observer are used to control the SRM. The flux calculator used in the slide mode observer is designed by phase voltage and the voltage drops in the phase resistance of the winding. The accuracy of the flux calculator is dependent on the phase resistance. For the continuous update of the phase resistance, current gradient at the inductance break point is used in this paper. The error of the estimated rotor position at the current gradient position is used to update the phase resistance to improve the sensorless scheme. The proposed sensorless speed control scheme is verified with a practical compressor used in home appliances. And the results show the effectiveness of the proposed control scheme.

Effect of Circadian Rhythms on the Bromobenzene Metabolism in Rats (랫드에 있어서 주야 시차가 Bromobenzene 대사에 미치는 영향)

  • 김광진;신중규;윤종국
    • Toxicological Research
    • /
    • v.13 no.4
    • /
    • pp.377-383
    • /
    • 1997
  • To investigate the circadian variation in the bromobenzene metabolism, bromobenzene(400 mg/kg body weight) was intraperitoneally administered to the rats every other day for 6 days both in the night; 24:00 and the day; 12:00. Each group of animals was sacrificed at 8hr after last injection of bromobenzene. The contents of hepatic CYP were more increased in control rats of night phase than those of day phase but in case of bromobenzene treatment there were no differences in hepatic CYP between rats of the night phase and those of day phase and the injection of prednisolon inhibited the hepatic CYP content in rats. Furthermore, the decreasing rate of hepatic glutathione contents to the control was higher in rats of day phase than those of night phase by the bromobenzene treatment. And the hepatic glutathione S-transferase activities were increased both in control and bromobenzene treated rats of the night phase than those of day phase. On the other hand, liver weight per body weight(%), hepatic lipid peroxide content, serum levels of alanine aminotransferase were more increased both in bromobenzene-treated and control rats of the night phase than those in the day phase. These results indicate that the rats of night phase may induce more accelerated formation of bromobenzene 3,4-oxide from bromobezene than those of day phase in rats.

  • PDF

Fuzzy logic based advance angle control for low voltage SRM (저전압 SR모터의 퍼지로직 기반 전상각 제어)

  • Kim, Kyu-Dong;Shin, Doo-Jin;Huh, Sung-Jae;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.22-25
    • /
    • 2001
  • In this paper, a fuzzy advance angle control method is described to drive an industrial low voltage SRM (Switched Reluctance Motor) for 10kW forklift truck. SRM has a highly non-linear characteristic that is due to change the rotor and stator. And low voltage SRM is designed that its phase resistance and phase inductance is very low to inject high current into the phase windings. In this reason, the proper current control is necessary to drive the low voltage SRM efficiently. SRM has positive torque at increasing inductance region and negative torque at decreasing inductance region. Due to this reason, the current has to be built up in the increasing phase inductance part as soon as possible. Therefore, the phase switch must be turned on before the phase inductance increases, and this angle is called as the advance angle. Also, the phase current has to be dropped before the phase inductance decreases. Fuzzy logic is a flexible and general-purposed method of implementing non-linear functions and as such it is useful in control applications. Consequently, we designed a fuzzy advance angle controller to control the phase current appropriately.

  • PDF

The speed control of the Single-Phase induction motor using P-I controller (비례 - 적분 제어기를 이용한 단상 유도 전동기의 속도 제어)

  • Sang, Doo-Whan;Cheong, Dal-Ho;Kim, Jung-Chul;Oh, Min-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.603-605
    • /
    • 1994
  • The Single-Phase induction motor is widely used in home appliances, especially refrigerator, air conditioner and washing machine. Recently many home appliances that use the motor require the speed control to get the various and convenient functions for the customers. Generally it is so hard to control the speed of the Single-Phase induction motor and to get the wide range of the speed variation. In this raper, the speed controller using P-I is designed for the Single-Phase induct ion Motor. The experimental results of the phase controller using P-I show the wide speed control of the Single-Phase induction motor and rebuff control to load change.

  • PDF

Simulink-based Modelling and Simulation for a Single-phase UPFC (Simulink를 이용한 단상 UPFC 모델링 및 시뮬레이션)

  • Kang, Moon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.523-530
    • /
    • 2009
  • This paper presents a study on a small scale single-phase UPFC preliminary researches on power quality compensating schemes of electrical railway. As the UPFC is very complicated power-electronic system consisting of grid-connected transformers, four single phase inverters interconnected with dc-link capacitors and various electrical apparatuses, multiple controllers and control algorithms are needed, and entire UPFC has been modelled in the form of block diagrams and simulated by using Simulink. The main purpose of the compensating system is to manage reactive and active powers with the four single phase inverters, so, the control effort has been focused on the power flow control and has been realized through the hysteresis current control of the single phase inverters. And transport-delayed PLL with additional delay-time compensating term has been used to synchronize a grid voltage and the simulation results have shown that the compensating term could improve PLL performance under some frequency variation of the voltage.

Compensation Method of Current Measurement Error for Vector-Controlled Inverter of 2-Phase Induction Motor (2상 유도전동기용 벡터제어 인버터를 위한 전류측정 오차 보상 방법)

  • Lee, Ho-Jun;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1204-1210
    • /
    • 2016
  • The phase currents must be accurately measured to achieve the instantaneous torque control of AC motors. In general, those are measured using the current sensors. However, the measured current signals can include the offset errors and scaling errors by several components such as current sensors, analog amplifiers, noise filter circuits, and analog-to-digital converters. Therefore, the torque-controlled performance can be deteriorated by the current measurement errors. In this paper we have analyzed the influence caused by vector control of 2-phase induction motor when two errors are included in measured phase currents. Based on analyzed results, the compensation method is proposed without additional hardware. The proposed compensation method was applied vector-controlled inverter for 2-phase induction motor of 360[W] class and verified through computer simulations and experiments.

A novel PLL control method for robust three-phase thyristor converter under sag and notch conditions

  • Lee, Changhee;Yoo, Hyoyol
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.87-88
    • /
    • 2014
  • The paper presents a novel phase locked loop(PLL) control method for robust three-phase thyristor dual converters under sag, notch, and phase loss conditions. This method is applied to three line to line voltages of grid to derive three phase angle errors from three separated single-phase PLLs. They can substitute for abnormal phase to guarantee the synchronization in the various grid fault conditions. The performance of novel PLL with moving average method is verified through simulations.

  • PDF