• 제목/요약/키워드: Phase analysis

검색결과 11,890건 처리시간 0.053초

무감독분류 기법에 의한 부분방전 데이터 분석 (Partial Discharge Data Analysis with Unsupervised Classification)

  • 조경순;홍선학
    • 디지털산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.9-16
    • /
    • 2018
  • This study described partial discharge(PD) distribution analysis between the XLPE(Cross-Linked PolyEthylene)and EPDM(Ethylene Propylene Diene Monomer) interface with unsupervised classification. The ${\phi}-q-n$ patterns were analyzed using phase resolved partial discharge(PRPD). K-means cluster analysis forms a cluster based on similarities and distances among scattered individuals, and analyzes the characteristics of the formed clusters, dividing the multivariate data into several groups according to the similarity of each characteristic, Is a statistical analysis that makes it easier to navigate. It was confirmed that the phase angle of the cluster with the maximum discharge charge was concentrated around $0^{\circ}$ and $180^{\circ}$ at 30 kV after the initial phase distribution localized around $90^{\circ}$ and $300^{\circ}$ expanded to the whole phase angle according to the voltage rise. The Euclidean distance between the center of gravity and the discharge charge in the ${\Phi}-q$ cluster increased with increasing applied voltage.

Single-Phase Z-Source AC/AC Converter with Wide Range Output Voltage Operation

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.736-747
    • /
    • 2009
  • A new type of single-phase Z-source AC/AC converter based on a single-phase matrix converter is proposed in this paper. The proposed single-phase Z-source AC/AC converter has unique features; namely that the output voltage can be bucked and in-phase/out-of-phase with the input voltage; that the output voltage can be boosted and in-phase/out-of-phase with the input voltage. The converter employs a safe-commutation strategy to conduct along a continuous current path, which results in the elimination of voltage spikes on switches without the need for a snubber circuit. The operating principles of the proposed single-phase Z-source AC/AC converter are described, and a circuit analysis is provided. To verify the performance of the proposed converter, a laboratory prototype based on a TMS320F2812 DSP was constructed. The simulation and the experimental results verified that the output voltage can be bucked-boosted and in-phase with the input voltage, and that the output voltage can be bucked-boosted and out-of-phase with the input voltage.

3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 시뮬레이션 (Simulation of Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL)

  • 임성훈;박충렬;한병성;박형민;조용선;최효상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.167-168
    • /
    • 2005
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-Tc superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

힐버트 변환을 이용한 디지털 위상천이기의 성능 분석 (Performance Analysis of digital phase shifter using Hilbert transform)

  • 서상규;정봉식
    • 융합신호처리학회논문지
    • /
    • 제14권1호
    • /
    • pp.39-44
    • /
    • 2013
  • 본 논문에서는 멀티암(multi-arm) 스파이럴 안테나용 디지털 위상천이기(digital phase-shifter)를 힐버트 변환(Hillbert transform)을 이용하여 설계하였다. 힐버트 변환은 입력신호에 포함된 모든 주파수 성분을 $90^{\circ}$ 위상천이 시키며, 퓨리에 변환(Fourier transform)과 역퓨리에 변환(Inverse FIT)을 통해 구현된다. 디지털 위상천이기는 ADC(Analog-digital converter)로 샘플링된 입력신호에 힐버트 변환을 적용하여 위상차가 $90^{\circ}$인 두 신호를 생성하고, 이 두 신호를 이용하여 입력신호의 위상을 천이위상만큼 천이시키게 한다. 힐버트 변환 기반의 디지털 위상천이기는 Xilinx사의 System generator로 설계되었고, 입력 잡음, FFT 포인트 수, 샘플링 주기, 입력신호의 초기위상 및 천이 위상각 등에 따른 위상천이 성능을 시뮬레이션 하였으며, Matlab 결과와 비교하여 일치함을 확인하였다.

3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 (Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL)

  • 임성훈;한태희;박형민;조용선;송재주;최명호;;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.112-113
    • /
    • 2006
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-$T_c$ superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF

A Note on Complex Two-Phase Sampling with Different Sampling Units of Each Phase

  • Lee, Sang Eun;Jin, Young;Shin, Key-Il
    • Communications for Statistical Applications and Methods
    • /
    • 제22권5호
    • /
    • pp.435-443
    • /
    • 2015
  • Two phase sampling design is useful to increase estimation efficiency using deep stratification, improved non-response adjustment and reduced coverage bias. The same sampling units are commonly used for the first and the second phases in complex two-phase sampling design. In this paper we consider a sampling scheme where the first phase sampling units are clusters and the second phase sampling units are list samples. Using selected clusters in first phase requires that we list up elements in the selected clusters from the first phase and then use the list as a secondary sampling frame for the second phase sampling design. Then we select second phase samples from the listed sampling frame. We suggest an estimator based on the complex two-phase sampling design with different sampling units of each phase. Also the estimated variances of the estimator obtained by using classic and replication variance methods are considered and compared using simulation studies. For real data analysis, 2010 Korea Farm Household Economy Survey (KFHES) and 2011 Korea Agriculture Survey (KAS) are used.

비정질 $As_{40}Se_{50-x}S_{x}Ge_{10}$ 박막의 구조특성에 관한 연구 (A Study on the Structure Properties of Amorphous $As_{40}Se_{50-x}S_{x}Ge_{10}$ Thin Film)

  • 김종빈;정홍배
    • 전자공학회논문지A
    • /
    • 제29A권11호
    • /
    • pp.106-112
    • /
    • 1992
  • In this paper, we analyze the structure characteristics of $As_{40}Se_{50-x}S_{x}Ge_{10}$ system bulk and thin films. As the results of XRD patterns, it identified amorphous state. In order to find the glass transition temperature($T_g$), crystallization($T_c$) and melting point ($T_m$)of bulk sample, it ascertained that TS1gT is 238$^{\circ}C$ in $As_{40}Se_{15}S_{35}Ge_{10}$, and 231$^{\circ}C$ in $As_{40}Se_{25}S_{25}Ge_{10}$ & $As_{40}Se_{50}Ge_{10}$ following the thernal analysis by DSC, DTA, & TGA method. Also it was confirmed the phase seperation of continuous phase and dispertion phase by the optical texture of polarizing microscope and $T_g$ near 20$0^{\circ}C$ in thin film. Therefore, it was found that it occurs the phase seperation of Ge-rich dontinuous phase and Se-rich dispersion phase following the EDS analysis of thin film and the surface SEM photograph.

  • PDF

과냉도에 따른 모세관 입구단에서의 냉매 상태 변화가 냉장고 냉매 소음에 미치는 영향의 실험적 분석 (Experimental Analysis of the Effect of Phase Change at the Entrance of a Capillary Tube by Sub-cooling Control on Refrigerant-induced Noise)

  • 오영후;김민성;한형석;김태훈;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1184-1190
    • /
    • 2012
  • This study is focused on the experimental analysis of the noise induced by phase change of refrigerant at the entrance of capillary tube. The refrigerant is usually two-phase condition when it flowed into the capillary tube. At the entrance of capillary tube, the phase condition of refrigerant is formed by sub-cool control. If it has sufficient sub-cool temperature, all of the vapor refrigerants turned to liquid, which means there is only liquid. Otherwise, the gas is coexisted. Based on this theory, we experiment on each case by changing sub-cool temperature using refrigerant-supplying equipment. The noise level is measured for each case and compared.

유체로 연성된 동일한 두 직사각 평판의 고유진동 해석 (Free Vibration Analysis of Two Identical Rectangular Plates Coupled with Fluid)

  • 정경훈;이성철;유계형
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.8-15
    • /
    • 2002
  • In order to investigate the vibration characteristics of fluid-structure interaction problem, we modeled two identical rectangular plates coupled with fluid. A commercial computer code, ANSYS was used to perform finite element analysis and FEM solutions were compared with the experimental results to verify the finite element model. As a result, comparison of FEM and experiment showed good agreement, and the transverse vibration modes, in-phase and out-of-Phase, were observed alternately in the fluid-coupled system. The effect of fluid gap size on the fluid-coupled natural frequency were investigated. It was shown that the mode numbers increased, the normalized natural frequencies monotonically increased. And it was also found that an increase of the fluid gap reduced the coupled natural frequencies for the in-phase modes but increased the coupled natural frequencies for the out-of phase modes, and eventually converged to the results of an infinite fluid gap.

여러 환경조건에 대한 고분자애자의 누설전류 특성 변화 (Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition)

  • 박재준;최인혁;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.