• 제목/요약/키워드: Phase analysis

검색결과 11,817건 처리시간 0.033초

Initial-phase Sensitivity Analysis of Harmonic Measurements via Windowed DFT

  • Song, Shuping;Wang, Fuzong;Cheng, Guozhu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2014
  • When the windowed DFT algorithm is applied in harmonic measurements, the problem of initial-phase sensitivity will be encountered, this has an effect on harmonic amplitude accuracy. In this paper, the origin of initial-phase sensitivity is analyzed and the main factors that influence the level of initial-phase sensitivity are demonstrated. A method of reducing initial-phase sensitivity is proposed to increase the stability of harmonic measurements. We found that initial-phase sensitivity is determined by the side lobe peak level of the window functions when synchronous deviation is fixed. In addition, increasing the length of the time recorded can be used to remove initial-phase sensitivity. The correctness and validity of our conclusions have been confirmed through numerical results and field tests.

원자력현미경의 위상차영상을 이용한 나노표면의 미소기계적 특성 평가 (Estimation of Nanomechanical Properties of Nanosurfaces Using Phase Contrast Imaging in Atomic Force Microscopy)

  • 안효석
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.115-121
    • /
    • 2007
  • Phase contrast imaging in atomic force microscopy showed a promise as an effective tool for better understanding of micromechanical properties of surfaces at nano scale. A qualitative estimation model for phase contrast images obtained with a tapping mode AFM was developed. This investigation demonstrated the high efficiency of combined analysis of topography and phase contrast images for characterizing nanosurfaces. Phase contrast images allowed estimation of relative stiffness(elastic modulus) of the sample surface. The phase contrast images revealed a significant inhomogeneity of the nano scale worn surfaces. Phase contrast images are also capable of revealing the formation of tribofilms.

PMP 형상 측정법의 위상보정에 관한 연구 (A study on the phase calibration of the phase measuring profilometry)

  • 이연태;강영준;황용선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 2002
  • The 3-D measurement using a sinusoidal grating pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. The PMP technique is discussed, and the analysis of the systematic errors, the calibration procedure designed to determined the optimal setting of the measurement parameters is illustrated. Results of measurements and calibrations on the measurement plane objects are described.

  • PDF

변상싸이리스터전동기의 특성 (Performance of Variable-Phase Thyristor Motor)

  • 황영문;이일천;김광태
    • 대한전기학회논문지
    • /
    • 제33권4호
    • /
    • pp.127-133
    • /
    • 1984
  • In this paper the performance of a variable-phase thyristor motor combined with a phase splitter and a single-phase tapped induction motor is investigated. The phase splitter consists of a bridge type thyristor switching circuit. The regulating power flow of the phase splitter is obtained from the switching phase difference of thyristor switching sequences. The proper switching performance improves the torque-speed-characteristics of the motor and its operation efficiency. We simplify the motor system th using the tapped windng reactances of the motor as the complementary element of the thyristor phase splitter. We discussed the practicality of this motor system through the analysis of simulation result and the voltage and the current wave forms obtained froms obtained from the experiment.

  • PDF

SRM의 저소음 구동을 위한 여자방식에 따른 특성해석 (Characteristic Analysis of Excitation Method for Reduction of Acoustic Noise of SRM)

  • 김태형;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.15-18
    • /
    • 2005
  • Switched reluctance drive does exhibit higher levels of vibration and acoustic noise than that of most competing drives. The main source of vibration in the switched reluctance drive is generated by rapid change of radial magnetic force when phase current is extinguished during commutation action. In this paper, some excitation method is proposed to reduce vibration and acoustic noise of the switched reluctance drive. The excitation strategies considered in this research are 1-phase, 2-phase and hybrid excitation method. 1-phase method is a conventional and 2-phase method is excited 2 phases simultaneously. The hybrid excitation has 2-phase excitation by long dwell angle as well as conventional 1-phase excitation. The vibration and acoustic noise are compared and tested. Suggested 2-phase and hybrid strategies reduce acoustic noise because the scheme reduces abrupt change of excitation level by distributed and balanced excitation.

  • PDF

Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

  • Kong, Wubin;Huang, Jin;Kang, Min;Li, Bingnan;Zhao, Lihang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.899-907
    • /
    • 2014
  • This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.

커패시터 구동형 단상유도전동기의 권선설계에 대한 연구 (A Study of Winding Design for Capacitor Run Single phase Induction Motor)

  • 함상환;임종빈;이주
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.776-780
    • /
    • 2011
  • This paper is concerned with winding design in capacitor-run single phase motor. Winding design in single phase induction motor is more complicated than that in three phase induction motor, because of using concentric winding in the single phase. Various winding designs are possible, and accordingly layout of the slot is calculated by formula. And then accurate design of winding is available. Using the design process in this paper, we can get the base model with slot layout and turns of windings of 1.12 kW single phase induction motor, and it is verified by finite element analysis. In this paper, winding design and winding layout of single-phase induction motor using concentric winding are suggested.

파형분석에 의한 1996년 12월 13일 영월지진의 특성 (Characteristics of the 13 December 1996 Yeongwol Earthquake Based on the Phase Analysis)

  • 김우한;지헌철;전명순;김성균
    • 한국지진공학회논문집
    • /
    • 제1권1호
    • /
    • pp.19-24
    • /
    • 1997
  • 파형분석에 의한 영월지진의 본진과 두 여진에 대하여 연구하였다. 한국자원연구소(KIGAM)에서 제공된 지진기록의 파형분석을 위하여 12개의 가능한 파형에 대하여 주시곡선과 두 점을 잇는 파선추적이 사용되었다. 영월지진의 파형분석 결과는 다음과 같은 특성을 보여준다. 1) 본진(규모 4.5)에서는 Pn파형이 명확이 보이지만 두 여진(규모 3.8과 2.5)에서는 Pn파형이 보이지 않는다. 2) 두 여진에는 Pg 혹은 PmP파형이 초동파로 도착한다. 3) 비록 콘라드 불연속면이 실제로 존재하더라도 지진기록에서 콘라드면과 관계되는 파형을 구분하기가 어렵다. 4) 경상분지밖에 위치하는 구례(GRE) 관측소의 지진기록은 Pn파형의 도착시간, 주파수 등에서 경상분지 내에 위치하는 관측소의 기록과 비교할 때 차이를 보인다.

  • PDF

편마비 환자의 계단과 경사로 보행 동안 하지의 운동학적 분석 (Kinematic Analysis of Lower Extremities during Staris and Ramp Walking with Hemiplegic Patients)

  • 천동환
    • The Journal of Korean Physical Therapy
    • /
    • 제25권5호
    • /
    • pp.297-302
    • /
    • 2013
  • Purpose: This study was conducted in order to investigate the kinematic gait parameter of lower extremities with different gait conditions (level walking, stair, ramp) in hemiplegic patients. Methods: Ten hemiplegic patients participated in this study and kinematic data were measured using a 3D motion analysis system (LUKOtronic AS202, Lutz-kovacs-Electronics, Innsbruk, Austria). Statistical analysis was performed using one-way repeated measure of ANOVA in order to determine the difference of lower extremity angle at each gait phase with different gait conditions. Results: Affected degree of ankle joint in the heel strike phase showed significant difference between level walking and climbing stairs, and toe off phase showed significant difference between level walking and climbing stairs, ramps, and climbing stairs. Affected degree of knee joint showed no significant difference in all attempts. Affected degree of hip joint in the toe off phase showed significant difference between level walking, ramps and stairs, and climbing ramps. Swing phase showed significant difference between sides for level walking and stairs, climbing ramps. Affected ankle joint of heel strike and toe off, and affected hip joint of toe off and the maximum angle of swing phase in the angle was increased. Unaffected side of the ankle joint, knee joint, and hip joint showed a significant increase in walking phase. Conclusion: These findings indicate that compared with level walking, different results were obtained for joint angle of lower extremity when climbing stairs and ramps. In hemiplegia patient's climbing ramps, stairs, more movement was observed not only for the non-affected side but also the ankle joint of the affected side and hip joint. According to these findings of hemiplegic patients when climbing stairs or ramps, more joint motion was observed not only on the unaffected side but also on the affected side compared with flat walking.

용접 잔류응력 완화에 미치는 변태 온도의 영향에 관한 수치적 모델링 (Numerical Modeling of the Transformation Temperature Effect on the Relaxation of Welding Residual Stress)

  • 장경복;강성수
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2552-2559
    • /
    • 2000
  • Most of ferrous b.c.c weld materials have martensitic transformation during rapid cooling after welding. It is well known that volume expansion due to the phase transformation could influence on the relaxation of welding residual stress. To apply this effect practically, it is necessary to establish a numerical model which is able to estimate the effect of phase transformation on residual stress relaxation quantitatively. For this purpose, the analysis is carried out in two regions, i.e., heating and cooling, because the variation of material properties following a phase transformation in cooling is different in comparison with the case in heating, even at the same temperature. The variation of material properties following phase transformation is considered by the adjustment of specific heat and thermal expansion coefficient, and the distribution of residual stress in analysis is compared with that of experiment by previous study. In this study, simplified numerical procedures considering phase transformation, which based on a commercial finite element package was established through comparing with the experimental data of residual stress distribution by other researcher. To consider the phase transformation effect on residual stress relaxation, the transition of mechanical and thermal property such as thermal expansion coefficient and specific heat capacity was found by try and error method in this analysis. In addition to, since the transformation temperature changes by the kind and control of alloying elements, the steel with many kinds of transformation temperature were selected and the effect of transformation on stress releasement was investigated by the numerical procedures considering phase transformation.