A Study on the Position Control of BLDC Motor with New Sliding Surface (새로운 슬라이딩 면을 가지는 BLDC 모터의 위치 제어에 관한 연구)

  • 박수식;이상오;정세교;이대식
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.84-88
    • /
    • 1997
  • A robust position control system for a BLDC motor using new sliding mode control strategy is presented. Using the new variable structure system, reaching phase problem is eliminated and performance is largely improved. The simulation results show the validity of proposed scheme.

  • PDF

Monte Carlo Study of Layered Heisenberg Ferromagnet

  • Lee, Kyuwon
    • Journal of Magnetics
    • /
    • v.6 no.4
    • /
    • pp.119-121
    • /
    • 2001
  • Monte Carlo simulation was employed to study the phase transition in the classical Heisenberg ferromagnet with variable interlayer interactions. The measured transition temperatures show a strong logarithmic dependence on J/J'where J and J'are the intralayer and the interlayer exchange interaction, respectively. The results were compared with the theoretical expectations and an empirical formula for the critical coupling was stained.

  • PDF

Induction Generator Using PWM Converter and Its Small-Scale Power Applications to Variable-Speed Renewable-Energy Generation

  • Ahmed Tarek;Nishida Katsumi;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2005
  • This paper describes a simple control structure and power conditioning system for an indirect vector controlled stand-alone induction generator (IG) used to operate under variable speed. The required reactive power for the IG system is supplied by means of a capacitor bank and a voltage-source PWM converter. Using a capacitor bank to transfer the reactive power to the IG under the rated speed and no-load conditions starts the IG operation and reduces the PWM converter size. The vector control structure for the variable speed IG power conditioning system compensates for changes in the electrical three-phase and DC loads while considering the magnetizing curve of the IG. The vector control structure is developed to regulate the DC link voltage of the PWM converter and the IG output voltage. The experimental and simulated performance results of the IG power conditioning system at various speeds and loads are given and show that this proposed scheme can be used efficiently for a variable speed, wind energy conversion system.

Spray Characteristics of Effervescent Swirl Injectors for Variable Thrust (가변추력을 위한 기체주입식 와류형 분사기의 분무특성)

  • Lee, Wongu;Hwang, Donghyun;Ahn, Kyubok;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.1-12
    • /
    • 2019
  • A fundamental study on a gas injection variable thrust method for thrust throttling in a liquid rocket engine was conducted. The gas injection variable thrust has the advantage of not only being able to control the thrust with a simple structure but it also increases the atomization performance through the injection pressure drop that increases in direct proportion to the density reduction. In this study, spray characteristics such as spray instability, spray pattern, spray angle, and breakup length based on changes in the liquid mass flow rate and amount of injected gas were investigated using effervescent swirl injectors.

Design of a RF fixed phase control circuit using I&Q Demodulator (I&Q Demodulator를 이용한 RF 고정 위상 제어기 설계)

  • Park, Ung-Hee;Chang, Ik-Soo;Huh, Jun-Won;Gang, In-Ho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.8-14
    • /
    • 1999
  • The active devices used at microwave frequency have the different phase shift according to input power. Especially, The difference of the phase shift is large in the saturation region of the amplifier. In this paper, we disigned the phase control system for fixing the different phase shift at device. With the high frequency nonlinear amplifier, we fabricated such system that the phase shift to be fixed automatically using the varible phase shifter. The variable phase shifter fixed total phase variation of the circuit using the information that was obtained from the comparison of imputsignal phase with output signal phase. Even though the input signal is 2-tone or FM type, we could estimate and also fix the phase variation on DUT Dynamic range is about 10dB. It has been experimented at 1960MHz using Teflon (H=31mil, ${\varepsilon}r$=3.2)

  • PDF

A study on the efficient simulation methods for an automatic power transmission system applying dynamic torque constraint (동적 구속조건을 적용한 자동변속장치의 효과적인 시뮬레이션방법에 관한 연구)

  • Jeong, Heon-Sul;Lee, Kyo-Ill
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.504-518
    • /
    • 1998
  • Degree-Of-Freedom(DOF) for most power transmission system varies according to the operation status which consists of friction elements to change the power flow or to adjust the speed ratio such as clutches, brakes or one-way clutches. To simulate the dynamic characteristics of automatic power transmission system which is a typical example of such a variable DOF systems, many sets of governing equations and complicated phase decision routines are necessary. In this paper dynamic constraint theorem is derived explaining the torque transmission characteristics during the clutch engagement process and a robust stable algorithm is developed describing this phase transition phenomenon effectively by introducing the concept of direct torque and virtual damping. Finally, applying this algorithm to a passenger car automatic transmission gear consisting of several friction elements, an efficient simulation methods for such a complex system will be suggested that is very simple and systematic.

Source frequency phase referencing observations of H2O and SiO masers toward the semi-regular variable star R Crateris

  • Kim, Dong-Jin;Cho, Se-Hyung;Yun, Young-Joo;Kim, JaeHeon;Choi, Yoon Kyung;Yoon, Dong-Whan;Yoon, Suk-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.58.4-59
    • /
    • 2015
  • We have performed single dish and VLBI monitoring observations of $H_2O$ and SiO masers toward the semi-regular variable star R Crateris using the Korean VLBI Network(KVN) 4 band receiving system. In the case of VLBI observations at 3 epochs, successful superposed maps of $H_2O$ and SiO masers were obtained on 2015 May by adopting the Source Frequency Phase Referencing(SFPR) method. These results enable us to investigate the development of outflow and asymmetric motions from SiO maser to $H_2O$ maser regions according to stellar pulsation which are closely related with a mass-loss process. Single dish monitoring observations were carried out from 2009 June to 2015 May. Intensity variations between $H_2O$ and SiO masers were investigated according to stellar phases together with peak velocity variations. We will compare the VLBI results with those of single dish.

  • PDF

Speed Sensorless Control of Switched Reluctance Motor (스위치드 리럭턴스 전동기의 센서리스 속도제어)

  • Shin, Kyoo-Jae;Kwon, Young-Ahn
    • Journal of IKEEE
    • /
    • v.2 no.2 s.3
    • /
    • pp.166-172
    • /
    • 1998
  • Switched reluctance motor(SRM) has the advantages of simple structure, low rotor inertia and high efficiency. However, position sensor is essential in SRM in order to synchronize the phase excitation to the rotor Position. The Position sensors increase the cost of drive system and tend to reduce system reliability. This paper investigates the speed control of sensorless SRM in which the Phase current and change rate are utilized in position decision, and the period of dwell angle is variable for speed control. The proposed system consists of Position decision circuit, speed controller, digital logic commutator, switching angle controller and inverter The performances in the proposed system are verified through the experiment.

  • PDF

The Effect of Self-controlled Feedback on Proprioception in Elbow Flexion of Healthy Subjects (정상성인의 팔굽 굽힘 시 자기통제 피드백이 고유수용성감각에 미치는 영향)

  • Yoon, Jung-Gyu
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.4
    • /
    • pp.493-500
    • /
    • 2012
  • PURPOSE: The purpose of this study was to investigate effect of self-controlled feedback on proprioception in elbow flexion. METHODS: Thirty young adult volunteered to participate and were randomly assigned to one of three groups (self-controlled, yoked, control). Power and velocity in elbow flexion was measured by PRIMUS RS (BTE Tech., Hanover, U.S.A). Statistical analysis was used multivariate ANOVA to know effect of self-controlled feedback on proprioception in elbow flexion. Post hoc was used Scheffe. RESULTS: In acquisition phase to practice effect, variable errors in self-controlled group was significantly low scored more than yoked and control group. In retention phase to learning effect, variable errors in self-controlled group was significantly low scored more than yoked and control group. CONCLUSION: Self-controlled feedback was more effective on movement control when the learner could make a decision about receiving feedback after the trial. This seems to support the view that self-controlled feedback benefits learning, because learners can make a decision about feedback based on their performance on a given trial.