• Title/Summary/Keyword: Phase Shifted Current Control

Search Result 33, Processing Time 0.035 seconds

A novel DC-DC Converter for 3[kW] Fuel Cell System Residential Application (3[kW]급 주택용 연료전지시스템에 사용되는 새로운 DC-DC 컨버터)

  • Lee, S.H.;Mun, S.P.;Lee, H.W.;Suh, K.Y.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.362-364
    • /
    • 2006
  • This paper presents a novel DC-DC Converter for 3 [kW] Fuel Cell System Residential Application. Phase shifted control is employed to regulate the output voltage and achieve soft switching. The transformer leakage inductance is utilized effectively to achieve zero voltage turn on for the power semiconductor switches. The current doubler rectifier has only one diode drop. The transformer secondary winding current rating is one half the load current. The overall effciency of the converter is improved.

  • PDF

Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems

  • Pirouz, Hassan Mohammadi;Bina, Mohammad Tavakoli
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.572-578
    • /
    • 2010
  • This paper discusses a transformerless shunt static compensator (STATCOM) based on a modular multilevel converter (MMC). It introduces a new time-discrete appropriate current control algorithm and a phase-shifted carrier modulation strategy for fast compensation of the reactive power and harmonics, and also for the balancing of the three-phase source side currents. Analytical formulas are derived to demonstrate the accurate mechanism of the stored energy balancing inside the MMC. Various simulated waveforms verify that the MMC based STATCOM is capable of reactive power compensation, harmonic cancellation, and simultaneous load balancing, while controlling and balancing all of the DC mean voltages even during the transient states.

An analysis of a phase- shifted parallel-input/series-output dual converter for high-power step-up applications (대용량 승압형 위상천이 병렬입력/직렬출력 듀얼 컨버터의 분석)

  • 강정일;노정욱;문건우;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.400-409
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output(PISO) dual converter for tush-power step-up applications has been proposed. Since the proposed converter shows a low switch turn-off voltage stress, switching devices with low conduction loss can be employed in order to improve the power conversion efficiency. Moreover, it features a low output capacitor root-mean-square(RMS) current stress, low input current and output voltage ripple contents, and fast control-to-output dynamics compared to its PWM counterpart. In this paper, the operation of the proposed converter is analyzed in detail and its mathematical models and steady-state solutions are presented. A comparative analysis with the conventional PWM PISO dual converter is also provided. To confirm the operation, features, and validity of the Proposed converter, experimental results from an 800W, 24-350Vdc prototype are presented.

  • PDF

LED Backlight Driving Circuits and Dimming Method

  • Kwon, Oh-Kyong;Jung, Young-Ho;Lee, Yong-Hak;Cho, Hyun-Suk;Nam, Ki-Soo;In, Hai-Jung
    • Journal of Information Display
    • /
    • v.11 no.4
    • /
    • pp.173-181
    • /
    • 2010
  • In this paper, light-emitting-diode (LED) backlight driving circuits and dimming method for medium-sized and large liquid crystal displays (LCDs) are proposed. The double loop control method, the intelligent-phase-shifted PWM dimming method, the fast-switching current regulator, and the current matching techniques are proposed to improve not only the current regulation characteristics and the power efficiency but also the current matching characteristics and the transient response of the LED current. The brightness of the backlight using the proposed local dimming method was determined from the histogram of the local block to reduce the power consumption of the backlight without image distortion. The measured maximum power efficiency of the LED backlight driving circuit for medium-sized LCDs was 90%, and the simulation results showed an 88% maximum power efficiency of the LED backlight driving circuit for large LCDs. The maximum backlight power-saving ratio of the proposed dimming method was 41.7% in the simulation with a high-contrast image. The experiment and simulation results showed that the performance of LEDs as LCD backlight units (BLUs) improved with the proposed circuits and method.

A High-Efficiency High-Power Step-Up Converter with Low Ripple Content

  • Kang Jeong-il;Roh Chung-Wook;Moon Gun-Woo;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.708-712
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output (PI SO) dual inductor-fed push-pull converter for high-power step­up applications is proposed. This converter is operated at a constant duty cycle and employs an auxiliary circuit to control the output voltage with a phase-shift between the two modules. It features a voltage conversion characteristic which is linear to changes in the control input, and high step-up ratio with a greatly reduced switch turn-off stress resulting in a significant increase in the converter efficiency. It also shows a low ripple content and low root-mean-square (RMS) current in the output capacitor. The operational principle is analyzed and a comparative analysis with the conventional pulse-width-modulated (PWM) PISO dual inductor-fed push-pull converter is presented. A 50kHz, 800W, 350Vdc prototype with an input of 20-32Vdc has also been constructed to validate the proposed converter. The proposed converter compares favorably with the conventional counterpart and is considered well suited to high-power step-up applications.

  • PDF

A Study of Post-current Effect in DC Inverter Resistance Spot Welding (DC 인버터 저항 스폿 용접에서 후전류 효과에 관한 연구)

  • Lee, Hui-Jun;Rhee, Se-Hun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.598-603
    • /
    • 2009
  • Resistance spot welding has been investigated to apply for manufacturing car bodies because of its high productivity. So quality of resistance spot weld is one of the major concerns for both automobile and aerospace industry. Current design trends in automotive manufacture have shifted emphasis to alternative lightweight materials in order to aid in producing vehicles with higher fuel efficiency and lower down the vehicle emission level for environmental control. There is increasing emphasis to provide lighter cars. Therefore there is an effort to use high strength steels such as HSLA, dual phase, in car body. However there is used in restricted because of difficulty in producing consistently high quality resistance spot welds. In this study, resistance spot welding schedules were developed to achieve acceptable welds with improved static mechanical properties. Improved resistance spot welding schedules were developed using post heating current to reduce the cooling rate, or in-process tempering to reduce the hardness of the weld produced. The effects of resistance spot welding process parameter on hardening fracture mode and static mechanical properties of the joints were determined.

  • PDF

Development of Traffic Signal Operation Strategies On Median Bus Lane (중앙버스전용차로제 실시에 따른 신호운영 방안 연구)

  • Kim Gyun-Jo;Kim Young-Chan;Kim Jin-Tae;Jung Kwang-Bok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.5 no.1 s.9
    • /
    • pp.21-30
    • /
    • 2006
  • For urban highway network, traffic control strategy paradigm has been shifted from the private auto-oriented to the public transit-oriented. Introduction of exclusive median bus lanes (EMBL) in Seoul, Korea, has especially accelerated such changes in transportation policy and thus highway environment. Left-turning movement treatment at signalized intersections where EMBL pass through has been emerged as one of the rising problems associated with a current signal head with 4-signal lens, the Korea standard. This study proposes a new signal phase operation scheme for signal operation at an isolated intersection where EMBL pass through. The authors propose to use of an exclusive bus signal head indicating right-of-way of transits on EMBL only. Based on it, three different phase operation scheme were developed for left-turn treatments for traffic control with (1) traffic responsive control mode and (2) time-of-day traffic control mode. In addition, methodologies to design and develop signal maps for the proposed signal phase schemes are also developed. The proposed operation can only be possible when additional uses of signal state relay boards are allowed.

  • PDF

Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle (하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발)

  • Kim, Jong-Cheol;Choi, Deok-Kwan;Park, Hae-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.261-265
    • /
    • 2005
  • This paper describes the DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle. DC-DC Converter is used for charging 12V auxiliary battery supplying electric power to head ramp, audio, ECU etc in automobiles. used DC-DC Converter Topology is PS-ZVS FB(Phase Shifted Zero Voltage Switching Full-Bridge) to reduce switching loss and EMI noise induced by high frequency operating condition. And For easy compensation and stable system response characteristic, current mode control method including slope compensation is employed. Constant current / constant voltage charging control method guarantee stable electric charging of auxiliary battery. Simulation toll PSIM6.0 is used for initial circuit parameter settings and H/W debuging. Thermal problems of Switching components in DC-DC Converter is improved by using Thermo Tracer.

  • PDF

Feasibility Study of Tapped Inductor Filter Assisted Soft-Switching PWM DC-DC Power Converter

  • Moisseev S.;Sato S;Hamada S;Wakaoka M
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.231-234
    • /
    • 2003
  • This paper presents a novel high frequency transformer linked full-bridge type soft-switching phase-shift PWM control scheme DC-DC power converter, which can be used as power conditioner fur small-scale fuel cell power generation system. Using full-bridge soft-switching DC-DC converter topology makes possible to use low voltage high performance MOSFETs to achieve high efficiency of the power conditioner. A tapped inductor filter is implemented in the proposed soft-switching converter topology to achieve soft-switching PWM constant high frequency operation for a wide load variation range. to minimize circulating and idling currents without using additional resonant circuit and auxiliary power switching devices. The practical effectiveness of the proposed soft-switching DC-DC converter is verified in laboratory level experiment with 1 kW 100kHz breadboard setup using power MOSFETs. Actual efficiency of 94-96$\%$ is obtained for the wide load range

  • PDF

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.