• 제목/요약/키워드: Phase Shift Method

Search Result 476, Processing Time 0.029 seconds

A Study on the Performance Analysis of 4-ary Scaling Wavelet Shift Keying (4-ary 스케일링 웨이브릿 편이 변조 시스템의 성능 분석에 관한 연구)

  • Jeong, Tae-Il;Ryu, Tae-Kyung;Kim, Jong-Nam;Moon, Kwang-Seok;Kim, Hyun-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1155-1163
    • /
    • 2010
  • An algorithm of the conventional wavelet shift keying is carried out that the scaling function and wavelet are encoded to 1(mark) and 0(space) for the input binary data, respectively. Two bit modulation technique which uses four carrier frequencies is existed. Four carrier frequencies are defined as scaling function, inversed scaling function, wavelet, and inversed wavelet, which are encoded to 10, 11, 00 and 01, respectively. In this paper, we defined 4-ary SWSK (4-ary scaling wavelet shift keying) which is two bit modulation, and it is derived to the probability of bit error and symbol error of the defined system from QPSK. In order to analyze to the performance of 4-ary SWSK, we are obtained in terms of the probability of bit error and symbol error for QPSK (quadrature phase shift keying), MFSK(M-ary frequency shift keying) and proposed method. As a results of simulation, we confirmed that the proposed method was superior to the performance in terms of the probability of bit error and symbol error.

Research about ESPI System Algorithm Development that Use Modulating Laser (Modulating Laser를 이용한 ESPI System algorithm 개발에 관한 연구)

  • Kim, Seong-Jong;Kang, Young-June;Park, Nak-Kyu;Lee, Dong-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.65-72
    • /
    • 2009
  • Laser interferometry is widely used as a measuring system in many fields because of its high resolution and its ability to measure a broad area in real-time all at once. In conventional laser interferometry, for example out-of-plane ESPI (Electronic Speckle Pattern Interferometry), in plane ESPI, shearography and holography, it uses PZT or other components as a phase shift instrumentation to extract 3-D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include nonlinear errors and limited time of use. In the present study, a new type of laser interferometry using a laser diode is proposed. Using Laser Diode Sinusoidal Phase Modulating (LD-SPM) interferometry, the phase modulation can be directly modulated by controlling the laser diode injection current thereby eliminating the need for PZT and its components. This makes the interferometry more compact. This paper reports on a new approach to the LD (Laser Diode) Modulating interferometry that involves four-frame phase shift method. This study proposes a four-frame phase mapping algorithm, which was developed to have a guaranteed application, to stabilize the system in the field and to be a user-friendly GUI. In this paper, the theory for LD wavelength modulation and sinusoidal phase modulation of LD modulating interferometry is shown. Using modulating laser and research of measurement algorithm does comparison with existent ESPI measurement algorithm. Algorithm measures using GPIB communication through most LabVIEW 8.2. GPIB communication does alteration through PC. Transformation of measurement object measures through modulating laser algorithm that develops. Comparison of algorithm of modulating laser developed newly with existent PZT algorithm compares transformation price through 3-D. Comparison of 4-frame phase mapping, unwrapping, 3-D is then introduced.

Determination of the Langmuir and Temkin Adsorption Isotherms of H for the Cathodic H2 Evolution Reaction at a Pt/KOH Solution Interface Using the Phase-Shift Method

  • Chun Jang-H.;Jeon Sang-K.;Chun Jin-Y.
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.1
    • /
    • pp.19-28
    • /
    • 2006
  • The phase-shift method for determining the Langmuir, Frumkin, and Temkin adsorption isotherms ($\theta_H\;vs.\;E$) of H for the cathodic $H_2$ evolution reaction (HER) at a Pt/0.1 M KOH solution interface has been proposed and verified using cyclic voltammetric, differential pulse voltammetric, and electrochemical impedance techniques. At the Pt/0.1 M KOH solution interface, the Langmuir and Temkin adsorption isotherms ($\theta_H\;vs.\;E$), the equilibrium constants ($K_H=2.9X10^{-4}mol^{-1}$ for the Langmuir and $K_H=2.9X10^{-3}\exp(-4.6\theta_H)mol^{-1}$ for the Temkin adsorption isotherm), the interaction parameters (g=0 far the Langmuir and g=4.6 for the Temkin adsorption isotherm), the rate of change of the standard free energy of $\theta_H\;with\;\theta_H$ (r=11.4 kJ $mol^{-1}$ for g=4.6), and the standard free energies (${\Delta}G_{ads}^{\circ}=20.2kJ\;mol^{-1}$ for $k_H=2.9\times10^{-4}mol^{-1}$, i.e., the Langmuir adsorption isotherm, and $16.7<{\Delta}G_\theta^{\circ}<23.6kJ\;mol^{-1}$ for $K_H=2.9\times10^{-3}\exp(-4.6\theta_H)mol^{-1}$ and $0.2<\theta_H<0.8$, i.e., the Temkin adsorption isotherm) of H for the cathodic HER are determined using the phase-shift method. At intermediate values of $\theta_H$, i.e., $0.2<\theta_H<0.8$, the Temkin adsorption isotherm ($\theta_H\;vs.\;E$) corresponding to the Langmuir adsorption isotherm ($\theta_H\;vs.\;E$), and vice versa, is readily determined using the constant conversion factors. The phase-shift method and constant conversion factors are useful and effective for determining the Langmuir, Frumkin, and Temkin adsorption isotherms of intermediates for sequential reactions and related electrode kinetic and thermodynamic data at electrode catalyst interfaces.

Fabrication and Modulation Characteristic of TE-selective P-I-i-I-N GaAs/Al0.35Ga0.65As waveguide phase modulator (TE 모드의 위상변화만을 일으키는 P-I-i-I-N GaAs/Al0.35Ga0.65As 도파로 위상변조기의 제작 및 변조 특성)

  • Kim, Sun-Pil;Lee, Sang-Sun;Lee, Seok;Woo, Deok-Ha;Kim, Sun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.184-188
    • /
    • 2003
  • We fabricated a P-I-i-I-N $GaAs/Al_{0.35}Ga_{0.65}As$waveguide phase modulator with significant phase shift for the TE mode but negligible for the TM mode. We selected the P-I-i-I-N structure to cause a phase shift about the TM mode. The wavelength of $\lambda=1.55$\mu\textrm{m}$ was measured for both the TE and TM modes, respectively. As a result, the measured phase shift efficiency ($\Delta\phi$) by using the Fabry-Perot resonance method was $7.9^{\circ}/V.mm$ for TE-polarized light. Also, no modulation was observed for TM-polarized light.

Qualitative Analysis of Film Thickness in Elastohydrodynamic Lubrication (탄성 유체 윤활에서의 유막 두께 측정에 관한 정성적 분석)

  • 최언진;장시열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.147-155
    • /
    • 1999
  • The film thickness and shape of elastohydrodynamic lubrication is measured by optical interferometer, which is the most precise method for EHL film measurement. However the interpretation of the image pattern from optical viscometer is not easy for two-dimensional shape. A newly developed method of image processing makes it possible to evaluate the film thickness and shape in every point of contact region with two dimensional aspects. In this study, we captured film shape of EHL film from the monochromatic incident light with the Image processing method, which uses phase shift method, and obtained the image analysis method for gray level image in order to qualitatively evaluate film shapes.

  • PDF

Development of Clutch Auto Calibration Algorithm for Automatic Transmission Shift Quality Improvement (자동변속기 변속품질 향상을 위한 클러치 자동보정 알고리즘 개발)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.3
    • /
    • pp.47-56
    • /
    • 2020
  • As a shift control of automatic transmission was managed with the electronic control unit (ECU), shift quality which is a measure of shift shock during gear change has markedly improved. However, the initial clutch pressure control of the clutch filling phase should continue to rely on the predetermined control input since the input and output speeds are unchanged until the shifting process attains the inertia phase. It is critical to minimize the clutch response time and control the clutch pressure accurately at the end of clutch fill to achieve quick shift response and smoothness. Advanced transmission companies have adopted an auto calibration method which establishes the databases for the clutch piston fill-up attributes and the frictional characteristics of the disks. In this study, a distinctive auto calibration algorithm for forklift transmission under development is proposed and verified with the real-vehicle test. The experimental calibration results showed consistent turbine dynamics at the initial stage of shifts with the properly calibrated clutch-fill control parameters. By using this technique, it is necessary to finalize the shift control for the various operation conditions.

Design of Linear Synchronous Motor for Thrust Force Ripple Reduction using Module Phase Set Shift (Module Phase Set Shift를 이용한 선형 동기 전동기의 추력 리플 저감 설계)

  • Ryu, Gwang-Hyeon;Lee, Hyung-Woo;Cho, Su-Yeon;Oh, Se-Young;Ham, Sang-Hwan;Im, Jong-Bin;Ahn, Han-Woong;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.848-849
    • /
    • 2011
  • Rotating machines are using gears to change the rotary motion into the linear motion, on the other hand, linear motors have a accurate position control and excellent dynamic characteristics because of generating a thrust force directly. But the important problem, one of the linear motor is a high thrust force ripple. Thrust force ripple has a bad effect on the position accuracy and the dynamic characteristics, so it is necessary to reduce the thrust force ripple. Cogging is one of the cause that affect thrust force ripple. Cogging has some connection with the GCD between pole pitch and teeth pitch It is proposed method to reduce a thrust ripple of the linear motor that chamfering, skew, and so on. In this paper, the module phase set shift(MPSS) is used to reduce a thrust force ripple that has a similar effect to skew. And propose a method that reduce a thrust force ripple more by use of chamfering.

  • PDF

Low frequency Multi-level Switching Strategy based on Phase-Shift Control (위상 변위제어기법을 이용한 저주파 다중레벨 스위칭 방식)

  • Song, Sung-Geun;Lee, Sang-Hun;Nam, Hae-Kon;Park, Sung-Jun;Lee, Man-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.520-528
    • /
    • 2006
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level inverter combined with H-Bridge Inverters and Transformers. and furthermore we suggested the new multi-level PWM inverter using PWM level to reduce THD(Total Harmonic Distortion). and we used the phase-shift switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi-level PWM inverter.

Optimized Operation of Dual-Active-Bridge DC-DC Converters in the Soft-Switching Area with Triple-Phase-Shift Control at Light Loads

  • Jiang, Li;Sun, Yao;Su, Mei;Wang, Hui;Dan, Hanbing
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.45-55
    • /
    • 2018
  • It is usually difficult for dual-active-bridge (DAB) dc-dc converters to operate efficiently at light loads. This paper presents an in-depth analysis of a DAB with triple-phase-shift (TPS) control under the light load condition to overcome this problem. A kind of operating mode which is suitable for light load operation is analyzed in this paper. First, an analysis of the zero-voltage-switching (ZVS) constraints for the DAB converter has been carried out and a reasonable dead-band setting method has been proposed. Secondly, the basic operating characteristics of the converter are analyzed. Third, under the condition of satisfying the ZVS constraints, both the reactive power and the root mean square (RMS) value of the current are simultaneously minimized and a particle swarm optimization (PSO) algorithm is employed to analyze and solve this optimization problem. Lastly, both simulations and experiments are carried out to verify the effectiveness of the proposed method. The experimental results show that the converter can effectively achieve ZVS and improved efficiency.

Implementation of High-Resolution Laser Distance Measurement System using Phase-Shift Method (위상천이 방법을 이용한 고분해능 레이저 거리측정 시스템 개발)

  • Park, Bee-Jay;Lee, Chung-Woo;Chung, Chung-Choo;Sho, Jae-Hyuk;Ong, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.589-591
    • /
    • 2004
  • In this paper, we developed a laser distance measurement(LDM) system based on DSP. We applied PPD(Pulsed Phase Detection) algorithm to the LDM system. The PPD algorithm calculate the distance from the LDM system to the object by using phase detection. Reference waveform at a fixed frequency is sampled by both the inner-loop and outer-loop pulse signal. The LDM system detects the difference of phase between the sampled signals. We obtained an accuracy of ${\sigma}=25.5mm$ from the LDM system.

  • PDF