• Title/Summary/Keyword: Phase Image

Search Result 1,438, Processing Time 0.028 seconds

Synthesis and Biodistribution of Cat's Eye-shaped [57Co]CoO@SiO2 Nanoshell Aqueous Colloids for Single Photon Emission Computed Tomography (SPECT) Imaging Agent

  • Kwon, Minjae;Park, Jeong Hoon;Jang, Beom-Su;Jung, Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2367-2370
    • /
    • 2014
  • "Cat's eye"-shaped $[^{57}Co]CoO@SiO_2$ core-shell nanostructure was prepared by the reverse microemulsion method combined with radioisotope technique to investigate a potential imaging agent for a single photon emission computed tomography (SPECT) in nuclear medicine. The core cobalt oxide nanorods were obtained by thermal decomposition of $Co-(oleate)_2$ precursor from radio isotope Co-57 containing cobalt chloride and sodium oleate. The $SiO_2$ coating on the surface of the core cobalt oxide nanorods was produced by hydrolysis and a condensation reaction of tetraethylorthosilicate (TEOS) in the water phase of the reverse microemulsion system. In vivo test, micro SPECT image was acquired with nude mice after 30 min of intravenous injection of $[^{57}Co]CoO@SiO_2$ core-shell nanostructure.

Quality Enhancement of a Complex Holographic Display Using a Single Spatial Light Modulator and a Circular Grating

  • Bang, Le Thanh;Piao, Yan Ling;Kim, Jong Jae;Kim, Nam
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.70-77
    • /
    • 2016
  • This paper proposes an optical system for complex holographic display that enhances the quality of the reconstructed three-dimensional image. This work focuses on a new design for an optical system and the evaluation of the complex holographic display, using a single spatial light modulator (SLM) and a circular grating. The optical system is based on a 4-f system in which the imaginary and real information of the hologram is displayed on concentric rectangular areas of the SLM and circular grating. Thus, this method overcomes the lack of accuracy in the pixel positions between two window holograms in previous studies, and achieves a higher intensity of the real object points of the reconstructed hologram than the original phase-reconstructed hologram. The proposed method provides approximately 30% less NMRS (Normal Root Mean Square) error, compared to previous systems, which is verified by both simulation and optical experiment.

Optical and Mechanical Characteristics of NF System and NF Gap Control (근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어)

  • Oh, Hyeong-Ryeol;Lee, Jun-Hee;Gweon, Dae-Gab;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

A RF Module for digital terrestrial and multi-standard reception (디지털 지상파 및 다중 표준 수신을 위한 RF 모듈 설계)

  • Go, Min-Ho;Park, Wook-Ki;Shin, Hyun-Sik;Park, Hyo-Dal
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.8-19
    • /
    • 2006
  • The RF Module which can be adjusted for a digital terrestrial and multi standard(DVB-C, ISDB-T, DVB-H) reception is developed. The Module by single conversion does divide a broadband(45MHz~860MHz) broadcasting channels into three-bands(UHF, VHF_HIGH, VHF_LOW) to satisfy some electrical performances such as image signal rejection, phase noise, IF flatness etc and digital reception specifications such as analog and digital adjacent channel protection, co-channel protection which is important in environment with co-existence both analog and digital broadcasting systems.

  • PDF

The Safety Survey Analysis and Consideration of Small Transformer (소형 변압기 안전성 실태 분석 및 고찰)

  • Kim, Sung-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

A Study on the Fuel Behaivor with Cavity Diameter in a Gasoline Direct Injection Engine (직분식 가솔린 엔진에서 피스톤 캐비티 반경에 따른 연료 거동 분석)

  • Kim, Tae-An;Kang, Jeong-Jung;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.472-477
    • /
    • 2003
  • This study was performed to investigate the behavior of vapor phase of fuel mixtures with different piston cavity diameters in a optically accessible engine. The images of vapor phases were measured in the motoring engine using exciplex fluorescence method. The conventional engine was modified as GDI engine with swirl flow. Fuel was injected into atmospheric nitrogen to prevent quenching phenomenon by oxygen. Injection pressure is 5.1MPa. Two dimensional spray fluorescence image of vapor phases was acquired to analyze spray behavior and fuel distribution inside of cylinder. Three injection timings were set at BTDC $180^{\circ}$, $60^{\circ}$and $60^{\circ}$. With a fuel injection timing of BTDC $60^{\circ}$, fuel-rich mixture was concentrated in near the cavity center. With a fuel injection timing of BTDC $60^{\circ}$, fuel-rich mixture level in the center region was highest in the S-type during the late compression stroke. With a fuel injection timing of BTDC $180^{\circ}$, fuel was not affected in a piston cavity and generally distributed as homogeneous mixture.

  • PDF

Mass Transfer Characteristics of Vertical Two-Phase Flows with Orifice Nozzle (오리피스 노즐 수직 2 상 유동의 물질전달 특성)

  • Kim, Dong Jun;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.817-824
    • /
    • 2015
  • Experiments were carried out to investigate the flow and mass transfer characteristics of an orifice nozzle. Measurements of primary and suction flow rates, dissolved oxygen concentration, and electric power were obtained. Vertically injected mixed-jet images were captured by a direct visualization technique with a high speed camera unit. The mass ratio, volumetric mass transfer coefficient, and mass transfer performance were calculated using the measured data. As the primary flow pressure increases, the mass ratio decreases slightly, while the volumetric mass transfer coefficient and electric power increase. As the primary flow pressure increases and the mass ratio decreases, the mass transfer rate increases because of the fine bubbles and wider distribution of the bubbles.

Structure-From-Motion Approach to the Reconstruction of Surfaces for Earthwork Planning

  • Nassar, Khaled;Jung, Young-Han
    • Journal of Construction Engineering and Project Management
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 2012
  • The reconstruction of surfaces from unorganized point clouds can provide very useful information for construction managers. Although point clouds are generally created using 3D scanners, they can also be generated via the structure-from-motion technique using a sequence of images. Here we report a novel surface reconstruction technique for modeling and quantifying earthworks that can be used for preliminary planning, project updates and estimating of earthwork quantities, as well as embedded planning systems in construction equipment. The application of structure-from-motion techniques in earth works is examined and its advantages and limitations identified. Data from 23 earthwork excavation construction sites were collected and analyzed. 3D surface reconstructions during the construction phase were compared to the original land form. Similar experiments were conducted with piles of earth and the results analyzed to determine appropriate ranges of use for structure-from-motion surface reconstructions in earthwork applications. The technique was found to be most suited to pile of materials with volumes less than 2000 m3. Piles up to 10 m in height and with base areas up to $300m^2$ were also successfully reconstructed. These results should be of interest to contractors seeking to utilize new technology to optimize operational efficiency.

Effective Watermark Detection Using Asymmetric Thresholds (비대칭 임계치를 이용한 효과적인 워터마크 검출 방법)

  • Shin, Chang-Doon;Oh, Hae-Seok
    • The KIPS Transactions:PartB
    • /
    • v.10B no.6
    • /
    • pp.619-628
    • /
    • 2003
  • In this paper, an effective watermark detection technique in the wavelet transform domain is proposed. In this proposed method, the image is 2-level wavelet transformed, and then the watermark with a binary logo is embedded into middle band except baseband and high band to consider Invisibility and robustness. In this paper, we use an asymmetric thresholds watermarking (ATW) in which detection threshold is higher than inserting threshold in order to enhance watermark detection ratio in attacked images. In watermark detection phase, the detection value is not changed when the difference of the selected wavelet neighboring coefficient pairs Is smaller than specific value. The experimental results show that the proposed method has good quality and is robust to various attacks such as the JPEG lossy compression, noise addition, cropping, blurring, etc.

Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction (회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법)

  • Chung, S.T.;Park, S.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF