• Title/Summary/Keyword: Phase Cancellation

Search Result 168, Processing Time 0.021 seconds

Noise Reduction of Anti-phase Shifting to Maximum Amplitude Response in a Helmet (최대 진폭 응답으로 역위상을 천이시킨 헬멧에서의 소음감쇠 기법)

  • 조병모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.7
    • /
    • pp.13-20
    • /
    • 2001
  • The active noise cancellation system offers a better low frequency performance with a smaller and lighter system compared to a passive one. This paper presents an active noise control system capable of reducing the noise in a helmet after attenuating the external noise using the helmet as the passive noise reduction system, which consists of a controller for inverting and compensating the phase delay, a microphone for picking up the external noise, and a loudspeaker for radiating the acoustic anti-phase signal to reduce the external noise. In this paper, external noise can be reduced by noise controller by compensating the phase difference to be 180°in the frequency of maximun value in the amplitude response. The noise of the phase delay covered from 50°to 310°was reduced in this system and it is possible to obtain a noise reduction of up to approximately 20 dB at the ears in the enclosure.

  • PDF

Prognostic Value of Day 3 Inhibin-B on Assisted Reproductive Technology Outcome (보조 생식술 결과에 있어서 기저혈중 Inhibin-B의 예후인자로서의 유용성)

  • Bai, Sang-Wook;Kim, Jin-Young;Lee, Kyung-Sool;Won, Jong-Gun;Lee, Yong-Joo;Yi, Ji-Won;Chang, Kyung-Hwan;Lee, Byung-Seok;Park, Ki-Hyun;Cho, Dong-Jae;Song, Chan-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.2
    • /
    • pp.217-223
    • /
    • 1997
  • This study was performed to determine if women with day 3 serum inhibin-B concentrations <45pg/ml (conversion factor to SI unit, 1.00) demonstrate a poor response to ovulation induction and assisted reproductive technology outcome to women with inhibin-B${\ge}45pg$/ml, independant of day 3 FSH, E2 and patient age. From Jan 1996 to Dec 1996, 16 volunteers patients who underwent 25 IVF cycles with luteal phase GnRH agonist suppression and HMG stimulation were allocated to the study group. We evaluated day 3 serum inhibin-B, FSH, E2, peak E2, cancellation rate per initiated cycle (%) and clinical pregnancy rate per initiated cycle (%) according to the above two groups and independent of patient age, day 3 FSH, day 3 E2 and all of above combined. Women with day 3 serum inhibin-B${\ge}45pg$/ml demonstrated higher average day 3 inhibin-B level, clinical pregnancy rate per initiated cycle ($20.3{\pm}2.5$ pg/ml vs $80.9{\pm}5.0$ pg/ml, p<0.05; 24.8% vs 8.5%, p<0.05) and lower day 3 FSH level, cancellation rate per initiated cycle ($6.9{\pm}0.3$ mIU/ml vs $8.5{\pm}0.5$ mIU/ml, p<0.05; 1.5% vs 9.0%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml and age<40 year demonstrated higher pregnancy rate per initiated cycle (28.2% vs 7.4%, p<0.05) and lows. day 3 FSH level, cancellation rate per initiated cycle ($6.9{\pm}0.5$ mIU/ml vs $8.2{\pm}0.7$ mIU/ml, p<0.05; 1.0% vs 9.0%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml and day 3 FSH<15mIU/ml demonstrated higher pregnancy rate per initiated cycle (33.5% vs 9.5%, p<0.05) and lower day 3 FSH level, cancellation rate per initiated cycle ($7.7{\pm}0.2$ mIU/ml vs $8.5{\pm}0.5$ mIU/ml, p<0.05; 1.5% vs 10.0%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml and day 3 E2<50pg/ml demonstrated higher pregnancy rate per initiated cycle (30.0% vs 9.5%, p<0.05) and lower cancellation rate per initiated cycle (1.5% vs 9.5%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml, age<40 year, day 3 FSH<15mIU/ml and day 3 E2<50pg/ml demonstrated higher pregnancy rate per initiated cycle (30.0% vs 10.8%, p<0.05) and lower day 3 FSH level, cancellation rate per initiated cycle ($6.8{\pm}0.6$ mIU/ml vs $8.4{\pm}0.9$ mIU/ml, p<0.05; 1.5% vs 7.8%, p<0.05). Therefore women with low day 3 serum inhibin-B concentrations demonstrate a poorer response to ovulation induction and are less likely to conceive a clinical pregnancy though ART relative to women with high day 3 inhibin-B and day 3 serum inhibin-B, in addition to a day 3 FSH, E2 and patient age, appears helpful in prediction in IVF-ET outcome.

  • PDF

An Adaptive Microphone Array with Linear Phase Response (선형 위상 특성을 갖는 적응 마이크로폰 어레이)

  • Kang, Hong-Gu;Youn, Dae-Hui;Cha, Il-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.53-60
    • /
    • 1992
  • Many adaptive beamforming methods have been studied for interference cancellation and speech signal enhancement in telephone conference and auditorium. Main aspect of adaptive beamforming methods for speech signal processing is different from radar, sonar and seismic signal processing because desire output signal should be apt to the human ear. Considering that phase of speech is quite insensible to the human ear, Sondhi proposed a nonlinear constrained optimization technique whose constraint was on the magnitude transfer function from the source to the output. In real environment the phase response of the speech signal affects the human auditorium system. So it is desirable to design linear phase system. In this paper, linear phase beamformer is proposed and sample processing algorithm is also proposed for real time consideration Simulation results show that the proposed algorithm yields more consistent beam patterns and deep nulls to the noise direction than Sondhi's.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

Full Bridge Resonant Inverter Using Asymmetrical Control with Resonant-frequency Tracking for Ultrasonic Cleaning Applications

  • Jittakort, Jirapong;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1150-1159
    • /
    • 2017
  • Flexibility in the power control of ultrasonic transducers has remained a challenge for cleaning applications. This paper introduces a modification of the existing piezoelectric ceramic transducer (PCT) circuit to increase the range of operation through its impedance characteristics. The output power is controlled using the asymmetrical voltage-cancellation (AVC) method. Together with a phase-locked loop control, the switching frequency of the inverter is automatically adjusted to maintain a lagging phase angle under load-parameter variations during the cleaning process. With the proposed modification, the region of the zero-voltage switching (ZVS) operation is extended, which results in a wider range of output power control. A hardware prototype is constructed and the control algorithm is implemented using an STM32F4 microcontroller. Simulation and experimental results are provided to verify the proposed method for a 50-W PCT. The operating frequency and output power ranges under study are 37 - 41 kHz and 15.8 - 50 W, respectively.

Harmonic Identification Algorithms Based on DCT for Power Quality Applications

  • Yepes, Alejandro G.;Freijedo, Francisco D.;Doval-Gandoy, Jesus;Sanchez, Oscar Lopez;Fernandez-Comesana, Pablo;Alvarez, Jano Malvar
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.33-43
    • /
    • 2010
  • The increasing demand for non-sinusoidal currents affects the quality of distribution networks. Harmonic detection is a crucial step in the cancellation of those components by active power filters. In this paper, the discrete cosine transform (DCT) is compared with different implementations based on Fourier transforms, demonstrating their equivalences and the advantages provided by the former. We demonstrate that the phase error in the presence of grid frequency deviations and the transient length are reduced by half in comparison to the discrete Fourier transform. A novel algorithm is developed to provide frequency adaptation to the DCT, taking advantage of its good features. The window width is adjusted in real time according to the actual value of the grid fundamental frequency by means of a phase-locked loop. A technique based on dithering is employed to overcome the limitation caused by the truncation of the window number of samples, so the frequency resolution is enhanced. The theoretical approach is verified by simulated and experimental results.

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

New Single-stage Interleaved Totem-pole AC-DC Converter for Bidirectional On-board Charger

  • ;Kim, Sang-Jin;Kim, Byeong-U;Sin, Yang-Jin;Choe, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.192-194
    • /
    • 2018
  • In this paper a new single-stage ac-dc converter with high frequency isolation and low components count is introduced. The proposed converter is constructed using two interleaved boost circuits in the grid side and non-regulating full bridge in the DC side. An optimized switching is implemented on the two interleaved boost circuits resulting in a ripple-free grid current without a ripple cancellation network; hence very small filter inductors are used. A simple and reliable closed-loop control system is easily implemented, since the phase-shift angle is the only independent variable. Moreover, current imbalance is avoided in the presented topology without current control loop in each phase. The proposed charger charges the battery with a sinusoidal-like current instead of a constant direct current. ZVS turn on of all switches is achieved throughout the operation in both directions of power flow without any additional components.

  • PDF

Maximum Power Point Tracking Controller Connecting PV System to Grid

  • Ahmed G. Abo-Khalil;Lee Dong-Choon;Choi Jong-Woo;Kim Heung-Geun
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.226-234
    • /
    • 2006
  • Photovoltaic (PV) generators have nonlinear V-I characteristics and maximum power points which vary with illumination level and temperature. Using a maximum power point tracker (MPPT) with an intermediate converter can increase the system efficiency by matching the PV systems to the load. This paper presents a maximum power point tracker based on fuzzy logic and a control scheme for a single-phase inverter connected to the utility grid. The fuzzy logic controller (FLC) provides an adaptive nature for system performance. Also the FLC provides excellent features such as fast response, good performance and the ability to change the fuzzy parameters to improve the control system. A single-phase AC-DC inverter is used to connect the PV system to the grid utility and local loads. While a control scheme is implemented to inject the PV output power to the utility grid at unity power factor and reduced harmonic level. The simulation results have shown the effectiveness of the proposed scheme.

Development of Human Detection Algorithm for Automotive Radar (보행자 탐지용 차량용 레이더 신호처리 알고리즘 구현 및 검증)

  • Hyun, Eugin;Jin, Young-Seok;Kim, Bong-Seok;Lee, Jong-Hun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.92-102
    • /
    • 2017
  • For an automotive surveillance radar system, fast-chirp train based FMCW (Frequency Modulated Continuous Wave) radar is a very effective method, because clutter and moving targets are easily separated in a 2D range-velocity map. However, pedestrians with low echo signals may be masked by strong clutter in actual field. To address this problem, we proposed in the previous work a clutter cancellation and moving target indication algorithm using the coherent phase method. In the present paper, we initially composed the test set-up using a 24 GHz FMCW transceiver and a real-time data logging board in order to verify this algorithm. Next, we created two indoor test environments consisting of moving human and stationary targets. It was found that pedestrians and strong clutter could be effectively separated when the proposed method is used. We also designed and implemented these algorithms in FPGA (Field Programmable Gate Array) in order to analyze the hardware and time complexities. The results demonstrated that the complexity overhead was nearly zero compared to when the typical method was used.