• Title/Summary/Keyword: Phase Calibration

Search Result 503, Processing Time 0.027 seconds

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

Analysis of Flumeqnine in Meats (식육 중 항생제 flumequine의 분석)

  • Kuk, Ju-Hee;Ko, Yong-Seok;Kim, Yong-Hoon;Yoon, Chang-Yong;Sun, Nam-Kyu;Kim, Eun-Jung;Seo, Jee-Woo;Park, Ji-Won;Kang, Kil-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • An analytical method for the determination of flumequine in meats was developed and validated using high-performance liquid chromatography with fluorescence detection. The samples were mixed with sodium sulfate and extracted with ethyl acetate. After clean-up, the residues were dissolved in mobile phase. The calibration curves showed high linearity ($r^2$=0.9979) within the concentration range of 0.1-1.0 mg/kg. The limit of detection and limit of quantification were validated at 0.005 and 0.017 mg/kg, respectively. The recoveries in fortified meats ranged from 90.8 to 101.1%. The method was then validated in correspondence with the CODEX guidelines for flumequine residue in meats. Herein we monitored 150 samples of meats that were purchased in Korea (Seoul, Busan, Daegu, Daejeon, and Gwangju). Among the tested samples, flumequine was detected in 1 of beef and 1 of pork at levels in the range of 0.048-0.080 mg/kg. Overall, the flumequine residues in the tested samples were within the Maximun residue limit.

Gas Chromatographic Analysis on the Residual of Fungicide Fenhexamid in Crops(Cucumber, Strawberry and Grape) (작물(오이, 딸기, 포도) 중 살균제 Fenhexamid의 잔류성에 대한 기체 크로마토그래피 분석)

  • Han, Seong-Soo;Lo, Seog-Cho;Kim, Won-Ju;Park, PiII-Jae;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.70-77
    • /
    • 2003
  • The optimum conditions for the residue analysis of hydroxyanilide fungicide fenhexamid on cucumber, strawberry and grape were investigated by gas chromatography equipped with electron capture detector (GC-ECD) and the residual amount was determined by sprayed days before harvest. Each samples were extracted with acetone, filtered and concentrated to 50 mL. The concentrated extracts were transferred to dichloromethane and then thoroughly concentrated. The concentrated phase was loaded on the filtration column stuffed with silica gel and purified with acetone:hexane (5:95, 15:85, v/v) mixed solvent. The regression equation and linearity of the standard calibration curves between 0.05~2.00 ng were as follows : cucumber; Y=312.40X+10.26, $R^2=0.9996$, strawberry; Y=313.33X+5.54, $R^2=0.9998$, grape; Y=253.27X-2.23, $R^2=0.9994$. From the standard additional experiments with 0.10 mg/L and 0.40 mg/L, the average recoveries of cucumber, strawberry and grape were 94.8%, 88.1% and 93.7%, respectively and the detection limits were all the same as 0.01 mg/L. Residual amounts in crops were ranged from 0.01 to 0.58 mg/L.

Development and Validation of Analytical Methods for Picoxystrobin Determination in Agricultural Products by GC-ECD and GC-MS

  • Do, Jung-Ah;Lee, Min-Hye;Park, Hyejin;Kang, Il-Hyun;Kwon, Kisung;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.332-338
    • /
    • 2012
  • A simple and sensitive analytical method was developed using gas chromatography with electron capture detector (GC-ECD) and gas chromatography-mass spectrometry (GC-MS) for determination of Picoxystrobin in agricultural products (apple, hulled rice, mushroom, pepper, soybean, and mandarin). Picoxystrobin residues were extracted with acetonitrile, partitioned with saline water, and then they were cleaned up on a florisil solid-phase extraction (SPE) cartridge to obtain an extract suitable for analysis by GC-ECD and GC-MS. The method was validated using 6 agricultural product samples spiked with Picoxystrobin at different concentration levels (0.02, 0.05 and 0.5 mg/L). Average recoveries of Picoxystrobin (using each concentration three replicates) ranged 64.0~98.3% with relative standard deviations less than 10%, calibration solutions concentration in the range 0.1~5 mg/L, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.02 mg/L, respectively. The result showed that the developed analytical method is suitable for Picoxystrobin determination in agricultural products.

Development of the Analytical Method for Diazepam in Fishery Products using Liquid and Gas Chromatography-tandem Mass Spectrometry (LC-MS/MS 및 GC-MS/MS를 활용한 수산물 중 디아제팜의 정량분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Kim, Joohye;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.110-117
    • /
    • 2018
  • The aim of this study was to develop an analytical method for the quantification of diazepam residues in fishery products, using liquid and gas chromatography-tandem mass spectrometry (LC-MS/MS and GC-MS/MS). The sample utilized in the study was extracted from the fish sample (crucian carp) using 0.1% formic acid in acetonitrile. For the utilization of the purification process, the dispersive solid phase extraction (dSPE) was used for LC-MS/MS, dSPE and SPE was used for GC-MS/MS, respectively. To be sure, the standard calibration curves showed a good linearity as the noted correlation coefficients, $r^2$ was > 0.99. The average recoveries for accuracy ranged in 99.8~124% for the samples which were fortified at three different levels (0.001, 0.002 and 0.010 mg/kg). The correlation coefficient for the precision effect was measured at a range of 4.01~11.8%. The limit of detection (LOD) for the diazepam analysis was 0.0004 mg/kg, and the limit of the quantification (LOQ) was 0.001 mg/kg. The proposed analytical method was characterized with a high accuracy and acceptable sensitivity to meet the established Codex Alimentarius Commission (CAC/GL71-2009) guideline requirements. We therefore established the optimal analysis method for the determination of diazepam in the fishery products using LC-MS/MS and GC-MS/MS. It would be applicable to analyze the diazepam residues in fishery products in further studies on this subject.

Determination of Nitrovin in Fishery Products by Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 니트로빈의 정량분석법 개발 및 검증)

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2018
  • The objective of this study was to develop a sensitive method for the identification and determination of nitrovin in fishery products by using a solid-phase extraction (SPE), as performed with a liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with a mixture of acetonitrile and water, and were then defatted with acetonitrile saturated hexane, after which further clean-up was accomplished with SPE on the hydrophilic-lipophilic balance (HLB) cartridges. The analytes were subsequently ionized in the positive mode of an electrospray ionization (ESI), and where thereby detected in a process of multiple reaction monitoring (MRM). The linearity (expressed as correlation coefficients) of the matrix calibration curves was > 0.985. The limit of the quantification for the nitrovin was measured at 0.001 mg/kg. The accuracy (expressed as average recovery) was noted between 72.1 and 122%. The precision (expressed as coefficient variation) was noted from 2.9 to 16.9%. According to the CODEX CAC/GL-71 guideline accuracy, precision, linearity, and limit of detection were determined in three matrices (which were flatfish, eel and shrimp). The proposed method was suitable for analyzing the associated nitrovin residues. This application and result can also be a factor to contribute to the non-detection drugs management in fishery products.

Development of Analytical Method for Sodium Alginate in Foods (식품 중 알긴산나트륨의 분석법 개발)

  • Kim, Hee-Yun;Hong, Ki-Hyoung;Choi, Jang-Duck;Park, Sung-Kwan;Jung, Si-Sub;Choi, Woo-Jeong;Ahn, Yeong-Sun;Hong, Yeong-Pyo;Song, Ok-Ja;Moon, Dong-Chul;Lee, Shin-Ho;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • Method of analyzing sodium alginate in foods was developed using high performance liquid chromatography (HPLC). HPLC conditions for sodium alginate were: column, MCI GEL $(8\;mm\;i.d{\times}300\;mm)$; mobile phase, deionized water; detector, refractive index detection (sensitivity = 16). Separation of sodium alginate was achieved within 15 min. Sodium alginate showed good linear relationship at 0.1-2.0% range. Correlation coefficient of calibration curve for sodium alginate exceeded 0.999, and detection limit was 0.005%. Recovery rate of sodium alginate in wheat flour dough was 106.67%. This method was successfully applied to analyses of cereals, saccharides, and ice cream, etc. Sodium alginate was detected in chocolate, noodles, and kelp at 0-44.8% range.

Validation on the Analytical Method of Ginsenosides in Red Ginseng

  • Cho B. G.;Nho K. B.;Shon H. J.;Choi K. J.;Lee S. K.;Kim S. C;Ko S. R.;Xie P. S.;Yan Y. Z.;Yang J. W.
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.491-501
    • /
    • 2002
  • A cross-examination between KT&G Central Research Institute and Guangzhou Institute for Drug Control was carried out in order to select optimum conditions for extraction, separation and determination of ginsenosides in red ginseng and to propose a better method for the quantitative analysis of ginsenosides. The optimum extraction conditions of ginsenosides from red ginseng were as follows: the extraction solvent, $70\%$ methanol; the extraction temperature, $100^{\circ}C;$ the extraction time, 1 hour for once; and the repetition of extraction, twice. The optimum separation conditions of ginsenosides on the SepPak $C_{18}$ cartridge were as follows: the loaded amount, 0.4 g of methanol extract; the washing solvents, distilled water of 25 ml at first and then $30\%$ methanol of 25 ml; the elution solvent, $90\%$ methanol of 5 ml. The optimum HPLC conditions for the determination of ginsenosides were as follows: column, Lichrosorb $NH_2(25{\times}0.4cm,$ 5${\mu}m$, Merck Co.); mobile phase, a mixture of acetonitrile/water/isopropanol (80/5/15) and acetonitrile/water/isopropanol (80/20/15) with gradient system; and the detector, ELSD. On the basis of the optimum conditions a method for the quantitative analysis of ginsenosides were proposed and another cross-examination was carried out for the validation of the selected analytical method conditions. The coefficient of variances (CVs) on the contents of ginsenoside-$Rg_{1}$, -Re and $-Rb_1$ were lower than $3\%$ and the recovery rates of ginsenosides were $89.4\~95.7\%,$ which suggests that the above extraction and separation conditions may be reproducible and reasonable. For the selected HPLC/ELSD conditions, the CVs on the detector responses of ginsenoside-Rg, -Re and $-Rb_1$) were also lower than $3\%$, the regression coefficients for the calibration curves of ginsenosides were higher than 0.99 and two adjacent ginsenoside peaks were well separated, which suggests that the above HPLC/ELSD conditions may be good enough for the determination of ginsenosides.

  • PDF

Development and Validation of Analytical Method for Decursin in Aerial Parts of Angelica gigas Nakai Extract (참당귀 지상부 추출물의 지표성분 decursin의 분석법 개발 및 검증)

  • Kim, Hee-Yeon;Lee, Ki-Yeon;Kim, Tae-Hee;Park, A-Reum;Noh, Hee-Sun;Kim, Si-Chang;Ahn, Mun-Seob
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Method development and validation of decursin for the standardization of Angelica gigas Nakai as a functional ingredient and health food were accomplished. The quantitative determination method of decursin as a marker compound of aerial parts of Angelica gigas Nakai extract (AAGE) was optimized by HPLC analysis using a C18 column ($3{\times}150mm$, $3{\mu}m$) with 0.1% TFA in water and acetonitrile as the mobile phase at a flow rate of 0.5 mL/min and detection wavelength of 330 nm. The HPLC/PDA method was applied successfully to quantification of the marker compound in AAGE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9994 and the limit of detection and limit of quantitation were $0.011{\mu}g/mL$ and $0.033{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 1.10% and 1.13%, respectively. Recovery of decursin at 0.5, 1, 5 and $10{\mu}g/mL$ were 92.38 ~ 104.11%. These results suggest that the developed HPLC method is very useful for the determination of marker compound in AAGE to develop a health functional material.

Correction of Lunar Irradiation Effect and Change Detection Using Suomi-NPP Data (VIIRS DNB 영상의 달빛 영향 보정 및 변화 탐지)

  • Lee, Boram;Lee, Yoon-Kyung;Kim, Donghan;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.265-278
    • /
    • 2019
  • Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) data help to enable rapid emergency responses through detection of the artificial and natural disasters occurring at night. The DNB data without correction of lunar irradiance effect distributed by Korea Ocean Science Center (KOSC) has advantage for rapid change detection because of direct receiving. In this study, radiance differences according to the phase of the moon was analyzed for urban and mountain areas in Korean Peninsula using the DNB data directly receiving to KOSC. Lunar irradiance correction algorithm was proposed for the change detection. Relative correction was performed by regression analysis between the selected pixels considering the land cover classification in the reference DNB image during the new moon and the input DNB image. As a result of daily difference image analysis, the brightness value change in urban area and mountain area was ${\pm}30$ radiance and below ${\pm}1$ radiance respectively. The object based change detection was performed after the extraction of the main object of interest based on the average image of time series data in order to reduce the matching and geometric error between DNB images. The changes in brightness occurring in mountainous areas were effectively detected after the calibration of lunar irradiance effect, and it showed that the developed technology could be used for real time change detection.