• Title/Summary/Keyword: Phase Calibration

Search Result 501, Processing Time 0.029 seconds

Complex Permittivity of Dry Sand Measured by an Open-Ended Coaxial Probe (개방단말 동축선 프로브로 측정된 마른 모래의 복소 유전율)

  • Shin, Hyun;Kim, Se-Yun;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.5
    • /
    • pp.17-24
    • /
    • 2000
  • Complex permittivity of dry sand is measured by using an open-ended coaxial probe, which was self-designed and manufactured. As a simple calibration scheme of the probe, the phase difference between the measured and the calculated reflection coefficients of pure water is subtracted from the phase of the measured reflection coefficient for dry sand. And then the complex permittivity of dry sand is reconstructed by applying its measured reflection coefficient into an improved imaginary transmission-line model. The accuracy of our measurement scheme is verified by showing that its reconstructed complex permittivity approaches the precise value of dry sand.

  • PDF

HPLC Analysis of Some Flavonoids in Citrus Fruits (조생온주 밀감의 품종에 따른 Flavonoids 함량 분석에 관한 연구)

  • 이창환;강영주
    • Food Science and Preservation
    • /
    • v.4 no.2
    • /
    • pp.181-187
    • /
    • 1997
  • New HPLC method was developed for determination of some flavonoids such as naringin, hesperidin, neohesperidin, rutin, quercitrin, naringenin, hesperetin and apigenin and their contents in citrus juice and citrus peel from citrus varieties Brown in Cheju. Detection was at 280nm and reverse phase ${\mu}$-Bondapak C-18 column was used. Water/methanol/acetic acid as the mobile phase was better than water/acetonitrile/acetic acid. Flavonoids were more stable in 20% n,n-dimethylformamide in methanol(20% DMF) than methanol and pH 12 adjusted by 1N-sodium hydroxide solution. Standard flavonoid solutions were injected three times consecutively and the reproduciability was 0.236 to 3.550%, Correlation coefficient of the calibration curve was 0.9946 to 0.9999. The exiraction efficiency of hesperidin from citrus peel was evaluated with different extraction method such as reflux, ultra-sonicating method, using three solvents (aqueous solutions with pH12 adjusted by 1N-sodium hydroxide, methanol and 20% DMF), respectively. The reflux for 4 hour in 20% DMF was the most efficient of the tested methods and solvents, and recovery percentage were 78.0∼130.0%. Flavonoids were determined in citrus juice. Naringin was 68.2mg/100$m\ell$ in Natsudaidai, Hesperidin were 85.6mg/100$m\ell$ in Sankyool and Neohesperidin was 25.3mg/100$m\ell$ in Dangyooja. Flavonoids were determined in citrus peel. Naringin was 110mg/g in Dangyooja, Hesperidin was 242mg/g in Hungjin and Neohesperidin was 87.9mg/g in Dangyooja.

  • PDF

Establishment of National Standard System for 240 kV High Voltage Transformer (240 kV 고전압 변성기 국가표준 시스템 구축)

  • Jung, Jae-Kap;Kwon, Sung-Won;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Han, Sang-Gil;Kim, Yoon-Hyoung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.164-169
    • /
    • 2008
  • National standard system for calibrating voltage transformer(VT) up to primary voltage of 240 kV have been established in 2005. The system consists of voltage source, regulating unit, VT testing unit, standard VT, VT under test and VT burden. To verify and validate the performance for 240 kV VT calibration system, the comparison with the National Measurement Institute of Australia(NMIA) has been performed using same VTs. The comparison results of the VTs mesured at the Korea Research Institute of Stansdards and Science(KRISS) are consistent with those measured at NMIA within 0.002 % for ratio error and 0.14 min for phase displacement in the primary voltage ranges of Vp = 3300 V - 22000 V with a secondary voltage of Vs = 110 V.

Quantitation of Mevinolinic Acid in Human Plasma by HPLC (고속액체크로마토그래피를 이용한 사람 혈장중 메비놀린 산의 정량)

  • Oh, Han-Suk;Park, Dong-Young;Seo, Sung-Hoon;Kim, Young-Gwan;Hong, Seon-Pyo;Choi, Young-Wook;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.279-282
    • /
    • 2000
  • Simple and precise high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of a HMG-CoA reductase inhibitor, $lovastatin^{TM}$ and its active metabolite (mevinolinic acid) in human plasma. The method involved solid phase extraction of mevinolinic acid and internal standard using Sep-Pak Cartridge. Samples were analyzed by reversed-phase HPLC using $Capcell-Pak\;C_{18}$ column with ultraviolet detection at 238 nm. The quantitation limit of mevinolinic acid was 2 ng/ml and the calibration curve was linear over the range of 2-50 ng/ml $(r^2>0.999)$ with human plasma. The analyses of quality control samples indicated that the normal values could be predicted with an accuracy >97%. The intra- and inter-day coefficients of variation for the analyses were <10%. The average recoveries were similar (79%) for mevinolinic acid and methylmevinolinic acid. The method described has been successfully applied to the quantification of mevinolinic acid in about 1,000 human plasma samples over six-month period.

  • PDF

Acetone PLIF for Fuel Distribution Measurements in Liquid Phase LPG Injection Engine (LPG 액상분사 엔진에서 아세톤 PLIF를 이용한 연료분포 측정기법 연구)

  • 오승묵;박승재;허환일;강건용;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.74-82
    • /
    • 2004
  • Planar laser-induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Acetone PLIF is chosen because fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone PLIF is applied to measure quantitative air excess ratio distribution in an engine fueled with LPG. Acetone is excited by KrF excimer laser (248nm) and its fluorescence image is acquired by ICCD camera with a cut-off filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile is suggested. Raw images are divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which is taken by a calibration process, are converted to air excess ratio distribution. This investigation shows instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

Determination of DBCP and n-Butylbenzene using SPME with GC-MS (SPME-GC-MS를 이용한 DBCP 및 n-Butylbenzene의 분석)

  • Park, Hyun-Mee;Kim, Young-Man;Lee, Dai-Woon;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.471-475
    • /
    • 2001
  • Solid phase microextraction(SPME) with $85{\mu}m$-polyacrylate (PA) and $100{\mu}m$-polydimethylsiloxane(PDMS) fibers, coupled to gas chromatography-mass spectrometry was used to determine 1,2-dibromo-3-chloropropane(DBCP) and n-butylbenzene in water. The conditions affecting the SPME process(i.e, extraction time, injection length, injection temperature, desorption time and temperature) were optimized. The linearity of the calibration curve (correlation coefficient, R) was over 0.99 and the limits of detection of the method were between 1.5 and $10.8{\mu}g/L$. Repeatability of the method was between 10.4 and 14.4 %.

  • PDF

Development of Chemiluminescence Immunoassay For the Measurement of Serum Thyroxine(T4)

  • Kim, J.B.;Choe, B.K.;Choi, S.H.
    • Korean Journal of Animal Reproduction
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1987
  • We describe a simple, solid-phase chemiluminescence immunoassay for the meausrement of serum T4. An immunoglobulin G fraction of antibody to thyroxine was passively absorbed onto the walls of polystyrene tubes. The labeled antigen was thyroxine-aminobutylethylisoluminol. After the bindings reaction (37$^{\circ}C$ for 1 hour), the solution is removed by aspiration and the antibody-bound fraction was washed once with buffer. Sodium hydroxide (5mol/1,200${mu}ell$) was added and the mixture incubated for 30 minutes at 6$0^{\circ}C$. Luminescence was initiated by oxidation of the label with micropeeroxidase-hydrogen peroxide and the signal of light emission was intergrated for 10 sec. The light yield was inversely proportional to the concentration of T4 in the standard or sample. An evaluation of the method gave the following values sensitivity of calibration curve 7.5$\pm$2.8 nmol/l (mean$\pm$SD). The intra-assay precision (CV%) was 8.9, 7.3 and 5.4. The inter-assay precision (CV%) was 10.2, 8.1 and 7.1. When seum samples were assayed for T4, the results obtained by solid-phase CIA and the conventional RIA agreed well(n=3.5, r=0.954).

  • PDF

Determination of N-nitrosodimethylamine in zidovudine using high performance liquid chromatography-tandem mass spectrometry

  • Yujin Lim;Aelim Kim;Yong-Moon Lee;Hwangeui Cho
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.281-290
    • /
    • 2023
  • Zidovudine is an antiretroviral agent prescribed for the prevention and treatment of human immunodeficiency virus/acquired immune deficiency syndrome (HIV/AIDS). It is typically recommended to be used in combination with other antiretroviral drugs. Zidovudine has the potential to generate N-nitrosodimethylamine (NDMA) in the presence of dimethylamine and nitrite salt under acidic reaction conditions during the drug manufacturing process. NDMA is a potent human carcinogen that may be detected in drug substances or drug products. An analytical method was developed to determine NDMA in pharmaceuticals including zidovudine using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The analysis involved reversed-phase chromatography on a Kinetex F5 column with a mobile phase comprising water-acetonitrile mixtures. The detection of positively charged ions was conducted using atmospheric pressure chemical ionization (APCI). The calibration curve demonstrated excellent linearity (r = 0.9997) across the range of 1-50 ng/mL with a highly sensitive limit of detection (LOD) at 0.3 ng/mL. The developed method underwent thorough validation for specificity, linearity, accuracy, precision, robustness, and system suitability. This sensitive and specific analytical method was applied for detecting NDMA in zidovudine drug substance and its formulation currently available in the market, indicating its suitability for drug quality management purposes.

A Cloud Point Extraction-Spectrofluorimetric Method for Determination of Thiamine in Urine

  • Tabrizi, Ahad Bavili
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1604-1608
    • /
    • 2006
  • A simple and efficient cloud point extraction-spectrofluorimetric method for the determination of thiamine in human urine is proposed. The procedure is based on the oxidation of thiamine with ferricyanide to form thiochrome, its extraction to Triton X-114 micelles and spectrofluorimetric determination. The variables affecting oxidation of thiamine, extraction and phase separation were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 2.5-1000 ng $mL^{-1}$. The limit of detection was 0.78 ng $mL^{-1}$ of thiamine and the relative standard deviation for 5 replicate determinations of thiamine at 400 ng $mL^{-1}$ concentration level was 2.42%. Average recoveries between 93-107% were obtained for spiked samples. The proposed method was applied to the determination of thiamine in human urine.

UPDATES OF IRC IMAGING TOOLKIT AND DATA ARCHIVE

  • Egusa, Fumi;AKARI/IRC team
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.33-35
    • /
    • 2017
  • We have been working on data processing and calibration of AKARI/IRC images from pointed observations. As of September 2014, a data package for each pointing only contains raw data and quick-look data, so that users have to process them using the toolkit by themselves. We plan to change this situation and to provide science-ready data sets, which are easy-to-use for non-AKARI experts. For Phase 1&2, we have updated dark and flat calibrations, and also the toolkit itself to produce images more reliable and easier to use. A new data package includes fully calibrated images with WCS information. We released it for about 4000 pointings at the end of March 2015.