• Title/Summary/Keyword: Phase Calibration

Search Result 501, Processing Time 0.033 seconds

A Study on Measurement and Analysis of In-Plane Deformations by Using Laser Speckle Interferometry (I) (레이저 스페클 간섭법을 이용한 면내 변형 측정 및 해석에 대한 연구 (I))

  • 강영준;노경완;강형수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.121-129
    • /
    • 1998
  • In-plane ESPI(Electronic Speckle Pattern Interferometry) was devised to measure in-plane deformations and rotation of a specimen with laser in this study. ESPI is a optical measuring method to be able to measure the deformations of engineering components and materials in industrial fields. The conventional measuring methods of surface deformations such as the strain gauge have many demerits because they are contact and point-to-point measuring ones. But that ESPI is noncontact, nondestructive and whole field measuring method can overcome previous disadvantages. We used ESPI which is sensitive to in-plane displacement for measuring in-plane deformations of a disk. And the 4-frame phase shifting method was used for the quantitative analysis. First of all, the system calibration was done due to an in-plane rotation before getting deformations of a disk. Finally we showed good agreement between the experiment results and those of the FEA(Finite Element Analysis).

  • PDF

The Analysis of Common Metabolites of Organophosphorus Pesticides in Urine by Gas Chromatography/Mass Spectrometry

  • 박성수;표희수;이강진;박송자;박택규
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2 : 1 : 10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 ㎍/㎖ in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants.

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속액체크로마토그라피를 이용한 홍삼 사포닌의 정량)

  • Kim, Cheon-Suk;Kim, Se-Bong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • Major saponins in ginseng were analysed using reverse phase high performance liquid chromatography with binary mobile phase gradient control system instead of normal phase column. The optimum condition were as following : reverse phase column; ${\mu}{\beta}ondapak\;C_{18}$ column (Waters, $3.9mm{\times}300\;mm,\;5{\mu}m$), methyl cyanaide/water binary mobile phase gradient control system, solvent flow rate; 1.5 ml/min, and UV($203{\mu}m$ ) detector. The complete separation of ginsenoside $Rb_1,\;Rb_2,\;Rc,\;Rd,\;Re,\;Rf\;and\;Rg_1$ was achieved within 55 min. The Regression coefficients of the calibration curves for seven ginsenosides were 0.99.

  • PDF

PHASE-B PRE-SIMULATION USING BORON AND GADOLINIUM AS POISON IN THE MODERATOR SYSTEM FOR WOLSONG-1

  • Kim, Sung-Min;Kim, Hyeong-Taek;Donnelly, Jim;Marleau, Guy
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.551-560
    • /
    • 2012
  • The Wolsong-1 (W-1) Phase-B pre-simulations were carried out in preparation for tests to be conducted for the restart of the reactor after a major refurbishment project that included replacement of the pressure tube. These pre-simulations for Wolsong-1 Phase-B differ from those in the past that were performed for the Wolsong-1,2,3,4 tests in that these tests use the WIMS/DRAGON/RFSP-IST code suite for verification of the tests and gadolinium instead of the traditional PPV/MULTICELL/RFSP code system and boron as poison in the moderator system. The use of gadolinium is deemed not to have domestically accumulated experience gained from the previous Phase-B tests. Thus, it is appropriate to conduct a study in order to gain a correct understanding and interpretation of potential differences in test results stemming from using gadolinium rather than boron. Although the calibration of the reactivity device will not be noticeably different using boron and gadolinium at a constant moderator temperature, the temperature dependency of the neutronic behavior due to the presence of gadolinium in the moderator system might be pronounced. The results of the pre-simulations using gadolinium revealed that the moderator temperature reactivity coefficients indeed showed significant differences in comparison with those with boron. In order to secure the validity of the analysis results, the newly acquired WIMS/DRAGON/RFSP-IST code suite was verified against the W-2,3,4 Phase-B test results. The results of the new code suite verifications revealed some overall improvements in accuracy; justification of the use of the code can be claimed for the validation of the W-1 Phase-B test results.

A 2-Gb/s SLVS Transmitter for MIPI D-PHY (MIPI D-PHY를 위한 2-Gb/s SLVS 송신단)

  • Baek, Seung Wuk;Jeong, Dong Gil;Park, Sang Min;Hwang, Yu Jeong;Jang, Young Chan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.25-32
    • /
    • 2013
  • A 1.8V 2-Gb/s scalable low voltage signaling (SLVS) transmitter (TX) is designed for mobile applications requiring high speed and low power consumption. It consists of 4-lane TX for data transmission, 1-lane TX for a source synchronous clocking, and a 8-phase clock generator. The proposed SLVS TX has the scaling voltage swing from 50 mV to 650 mV and supports a high speed (HS) mode and a low power (LP) mode. An output impedance calibration scheme for the SVLS TX is proposed to improve the signal integrity. The proposed SLVS TX is implemented by using a 0.18-${\mu}m$ 1-poly 6-metal CMOS with a 1.8 V supply. The simulated data jitter of the implemented SLVS TX is about 8.04 ps at the data rate of 2-Gb/s. The area and power consumption of the 1-lane of the proposed SLVS TX are $422{\times}474{\mu}m^2$ and 5.35 mW/Gb/s, respectively.

Cadmium Extraction from Solutions by Solid-Phase and its Trace Determination (고상에서 용액으로 부터 카드뮴 추출과 잔유물 측정)

  • Ashrafi, F.;Attaran, A.M.;Kermani, N. Memar
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.133-139
    • /
    • 2008
  • A new sensitive and selective spectrophotometric method for determination of trace amounts of cadmium using a polyvinyl chloride membrane containing bis-(2-ethylhexyl)phthalate as a solid phase extraction medium was investigated. Bis-(2-ethylhexyl)phthalate has used as a plasticizer. Cd(II) in an aqueous solution was trapped on the membrane in the form of colorful Cd (II)-I- - MG complexes (which MG is malachite green) and the cadmium complex was concentrated in the membrane. The absorbance of the green membrane was measured at 629 nm using a spectrophotometer, and then, the concentration of the cadmium was calculated using a calibration curve, which expressed the relationship between the Cd(II) concentration and the membrane absorbance after coloring for 25 min. The calibration curve was linear in the range of 10-760 μgL-1 cadmium in the test solution. The detection limit based on the 3Sbl criterion was 1.8199 μgL-1 and the relative standard deviations (RSD) were less than 4 % (n=5). The proposed method has been successfully applied to the determination of trace amounts of cadmium in the Tadjan River water sample (Sari-Iran), and the mean value of 28.7 μgL-1 was obtained.

Comparative Study of Extracting Fragrance Allergens by GC-MS/MS

  • Lee, In Ja;Ahn, Jae-Chan;Kim, Bogsoon;Chung, Deukmo
    • Mass Spectrometry Letters
    • /
    • v.8 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • Products containing any one or more of 26 fragrance allergens likely to cause contact allergies, are required under the 2008 domestic cosmetic law to be labeled when their concentrations exceed a certain range. This study focuses on the comparison and development of analytical methods based on headspace-solid phase micro extraction (HS-SPME) and liquid-liquid extraction (LLE) methods followed by GC-MS/MS for 24 of the fragrance allergens excepting for two natural materials in water samples. Using the developed HS-SPME method, 15 of the 24 fragrance allergens were analyzed and 9 compounds which have relatively low $logK_{OW}$ values (below about 2.5) were not extracted, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9969 or more, and the method detection limits (MDL) and the limits of quantification (LOQ) were $0.078{\sim}0.582{\mu}g/L$ and $0.261{\sim}1.940{\mu}g/L$, respectively. In the case of using the optimized LLE method, all 24 fragrance allergens were analyzed, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9957 or more, MDL and LOQ were $0.020{\sim}0.138{\mu}g/L$ and $0.065{\sim}0.440{\mu}g/L$, respectively.

Implementation and Verification of Linear Phase filter with Variable Cutoff Frequency for PCM/FM transmission (PCM/FM 전송을 위한 가변 컷오프 주파수 특성의 선형위상 필터 구현 및 검증)

  • Lee Sang-Rae;Ra Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.713-724
    • /
    • 2006
  • The purpose of this study is to design, implement and verify the pre-modulation filter with the variable -3dB cutoff frequency and linear phase response for bandlimiting the allocation of radio frequency bandwidth for PCM/FM transmission. For the design of this required filter, the digital FIR filter, DAC system and tuneable 2nd order LPF have been constructed and simulated according to the attenuation characteristic requirement of the amplitude frequency response by each stage. From these results, we have implemented the filter and verified the analog conversion hardware part which is composed of DAC system and tuneable 2nd order LPF for the interpolation of the discrete sequences. Especially this paper proposes and carries out the verification processes using the tone generator and the calibration procedures for more precise frequency response of the filter.

A 285-fsrms Integrated Jitter Injection-Locked Ring PLL with Charge-Stored Complementary Switch Injection Technique

  • Kim, Sungwoo;Jang, Sungchun;Cho, Sung-Yong;Choo, Min-Seong;Jeong, Gyu-Seob;Bae, Woorham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.860-866
    • /
    • 2016
  • An injection-locked ring phase-locked loop (ILRPLL) using a charge-stored complementary switch (CSCS) injection technique is described in this paper. The ILRPLL exhibits a wider lock range compared to other conventional ILRPLLs, owing to the improvement of the injection effect by the proposed CSCS. A frequency calibration loop and a device mismatch calibration loop force the frequency error to be zero to minimize jitter and reference spur. The prototype chip fabricated in 65-nm CMOS technology achieves a $285-fs_{rms}$ integrated jitter at GHz from the reference clock of 52 MHz while consuming 7.16 mW. The figure-of-merit of the ILRPLL is -242.4 dB.

Near-Field Rx-Measurement for Active Phased Array of Digital Radar Using Calibration Path (보정 경로를 활용한 디지털 레이더의 능동 위상 배열 근접전계 수신시험)

  • Yu, Je-Woo;Chae, Heeduck;Park, Jongkuk;Lim, Jae-Hwan;Kim, Duckhwan;Jin, Hyoung-Seog;Kim, Han-Saeng
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.504-511
    • /
    • 2016
  • In this paper, the method is proposed that the equivalent result can be obtained by compensating the variation of gain and phase in the comparison with the result of near-field measurement which is obtained in the steady state, although the gain and phase variation of rx-channels occurred in the near-field rx-measurement of digital active phased array antenna. The proposed concept has the time section for monitoring the state of the rx-channels through the calibration path in the measurement timeline, and is the method for compensating the variation of state. For validating the proposed method, the fabricated X-band digital active phased array antenna and the planar near-field measurement facility is utilized. The proposed method is validated in the comparison with the compensated pattern which the unstable state of rx-channels is calibrated and the reference pattern obtained under the steady state of the rx-channels.