• 제목/요약/키워드: Phase Balance

검색결과 519건 처리시간 0.03초

An explicit approximation of the central angle for the curved interface in double-circle model for horizontal two-phase stratified flow

  • Taehwan Ahn;Dongwon Jeong;Jin-Yeong Bak;Jae Jun Jeong;Byongjo Yun
    • Nuclear Engineering and Technology
    • /
    • 제56권8호
    • /
    • pp.3139-3143
    • /
    • 2024
  • Stratified flow in horizontal tubes is frequently observed in gas-liquid two-phase flow system. In the two-fluid modeling, it is important to define the interface shape in solving the balance equations to determine the key parameters such as the interfacial transfer terms, void fraction, and pressure drop. A double-circle model is usually introduced to depict the concave-down interface in a horizontal circular tube under the stratified-wavy flow condition. However, calculation of the central angle in the double-circle model, which represents the interfacial curvature, requires an appropriate iterative numerical root-finding scheme to solve the implicit transcendental equation. In this study, an explicit approximate equation has been proposed without requirement of the iterative scheme and numerical instability, which is expected to improve the coding process and computation efficiency in the analysis code with the two-fluid model.

연료전지 전극(Cathode)의 성능해석 및 설계에 관한 연구 (A Study on the Performance Analysis and Design of Cathode in Fuel Cells)

  • 김홍건;강성수;송하영;강영우;곽이구
    • 한국공작기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.75-79
    • /
    • 2007
  • The cathode design is one of the most important parts in order to enhance the performance of fuel cells. A 3-D model of the porous oxygen reducing cathode with perforated current collectors is analysed for the enhanced design in fuel cells. Simulation is performed using equations of electric potential balance, momentum balance, and mass balance. The gas concentrations are quite large and are significantly affected by the reactions that take place. The weight fraction of oxygen, velocity field for the gas phase, and local overvoltage are illustrated in the porous reactive cathode layer. The current density is also analysed and the result shows the distribution and variation are stated in a wide range. It is found that the rate of reaction and the current production is higher beneath the orifice, and decreases as the distance to the gas inlet increases. The significance of the results is discussed in the viewpoint of the mass transportation phenomena, which is inferred that the mass transport of reactants dictates the efficiency of the electrode in this design and at these conditions.

전후방향의 플랫폼 이동에 대한 동적균형 회복 특성 (Characteristics of Dynamic Postural Control in Anteroposterior Perturbation of a Platform)

  • 태기식;김영호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1066-1069
    • /
    • 2002
  • Dynamic postural control varies with the environmental context, specific task and intentions of the subject. In this paper, dynamic postural control against forward-backward perturbations of a platform was estimated using tri-axial accelerometers and a force plate. Ten young healthy volunteers stood upright in comfortable condition on the perturbation system which was controlled by an AC servo motor. With anterior-posterior perturbations, movements of ankle, knee and hip Joints were obtained by tri-axial accelerometers. and ground reaction forces with corresponding displacements of the center of pressure(CoP) by the force plate. The result showed that the ankle moved first and the trunk forward, which implies that the mechanism of the dynamic postural control in forward-backward perturbations, occurred in the procedure of the ankle, the knee and the hip. Knee flexion and hip extension in the period of acceleration, constant velocity and deceleration phase is very important fur the balance recovery. These responses depends on the magnitude and timing of the perturbation. From the present study the accelerometry-system appears to be a promising tool for understanding kinematic accelerative In response to a transient platform perturbation. A more through understanding of balance recovery mechanism may aid in designing methods for reducing falls and the resulting injuries.

  • PDF

Experimental investigations and development of mathematical model to estimate drop diameter and jet length

  • Roy, Amitava;Suneel, G.;Gayen, J.K.;Ravi, K.V.;Grover, R.B.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3229-3235
    • /
    • 2021
  • The key process used in nuclear industries for the management of radiotoxicity associated with spent fuel in a closed fuel cycle is solvent extraction. An understanding of hydrodynamics and mass transfer is of primary importance for the design of mass transfer equipment used in solvent extraction processes. Understanding the interfacial phenomenon and the associated hydrodynamics of the liquid drops is essential for model-based design of mass transfer devices. In this work, the phenomenon of drop formation at the tip of a nozzle submerged in quiescent immiscible liquid phase is revisited. Previously reported force balance based models and empirical correlations are analyzed. Experiments are carried out to capture the process of drop formation using high-speed imaging technique. The images are digitally processed to measure the average drop diameter. A correlation based on the force balance model is proposed to estimate drop diameter and jet length. The average drop diameter obtained from the proposed model is in good agreement with experimental data with an average error of 6.3%. The developed model is applicable in both the necking as well as jetting regime and is validated for liquid-liquid systems having low, moderate and high interfacial tension.

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.

Correlation among triceps surae muscle structure, balance, and gait in persons with stroke

  • Park, Hye-Kang;Yu, Ki-Gon;Shin, Jang-Hoon;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권3호
    • /
    • pp.155-164
    • /
    • 2020
  • Objective: This study aimed to compare muscle structure, balance, and gait parameters between healthy adults and persons with stroke and to analyze the correlation among these variables. Design: Cross-sectional study. Methods: Twenty persons with stroke (11 male, 9 female) and twenty healthy participants (9 male, 11 female) were included. Ultrasound images of the triceps surae and the tibialis anterior were acquired in sitting resting, sitting co-contraction, and standing resting positions and also during the functional reach test (FRT) and single leg anterior reaching test (SLART). Muscle thickness and fascicle length were measured. Spatiotemporal parameters of gait were measured using a pressure walkway. Gait speed, cadence, step length, stride length, stance time, and swing time were measured. Results: Changes in percent fascicle length were significantly greater in the gastrocnemius and soleus (SOL) muscles of healthy adults in the sitting co-contraction position (p<0.05). The percent fascicle length of the SOL in FRT and SLART were significantly greater in healthy adults (p<0.05). The mid-stance phase of stroke patients was shorter than healthy adults (p<0.05). A negative correlation was observed between percent fascicle length of the SOL in the sitting co-contraction position and the proportion of the mid-stance phase (p<0.05). Conclusions: The function of the triceps surae is affected in persons with stroke when compared with healthy adults. This can lead to difficulty in performing tasks that involve forward transfer of weight. If the triceps surae is not sufficiently secured, the possibility of compensation in the stance phase increases during gait.

Cardiac Autonomic Control and Neural Arousal as Indexes of Fatigue in Professional Bus Drivers

  • Lecca, Luigi I.;Fadda, Paolo;Fancello, Gianfranco;Medda, Andrea;Meloni, Michele
    • Safety and Health at Work
    • /
    • 제13권2호
    • /
    • pp.148-154
    • /
    • 2022
  • Background: Bus driving is a mentally demanding activity that requires prolonged attention to ensure safety. The aim of the study was to assess mental fatigue caused by driving a public bus and to find a profile of workers at higher risk. Methods: We evaluated changes of critical flicker fusion (CFF) (index of central arousal) and heart rate variability (HRV) (index of autonomic balance) in a 6-hour driving shift on a real route, in 31 professional bus drivers, and we tested the influence of personal factors such as sleep quality, BMI, and age. Paired t-test was used to test differences of CFF and HRV between both initial and final phase of driving, while multiple linear regression tested the influence of personal variables on the indexes of mental fatigue. Results: Results showed that CFF significantly decreased after 6 hours of bus driving (41.91 Hz, sd 3.31 vs. 41.15 Hz, sd 3.15; p = 0.041), and heart rate significantly decreased in the final phase of driving, with respect to the initial phase (85 vs. 78 bpm, p = 0.027). Increasing age (beta = -0.729, p = 0.022), risk of obstructive sleep apnea syndrome (beta = -0.530, p = 0.04), and diurnal sleepiness (beta = -0.406, p = 0.017) showed a significant effect on influencing mental fatigue. Conclusion: Elderly drivers at higher risk of sleep disorders are more prone to mental fatigue, when exposed to driving activity. Monitoring indexes of central arousal and autonomic balance, coupled with the use of structured questionnaires can represent a useful strategy to detect profile of workers at higher risk of mental fatigue in such duty.

Design of a New Harmonic Noise Frequency Filtering Down-Converter in InGaP/GaAs HBT Process

  • Wang, Cong;Yoon, Jae-Ho;Kim, Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제9권2호
    • /
    • pp.98-104
    • /
    • 2009
  • An InGaP/GaAs MMIC LC VCO designed with Harmonic Noise Frequency Filtering(HNFF) technique is presented. In this VCO, internal inductance is found to lower the phase noise, based on an analytic understanding of phase noise. This VCO directly drives the on-chip double balanced mixer to convert RF carrier to IF frequency through local oscillator. Furthermore, final power performance is improved by output amplifier. This paper presents the design for a 1.721 GHz enhanced LC VCO, high power double balance mixer, and output amplifier that have been designed to optimize low phase noise and high output power. The presented asymmetric inductance tank(AIT) VCO exhibited a phase noise of -133.96 dBc/Hz at 1 MHz offset and a tuning range from 1.46 GHz to 1.721 GHz. In measurement, on-chip down-converter shows a third-order input intercept point(IIP3) of 12.55 dBm, a third-order output intercept point(OIP3) of 21.45 dBm, an RF return loss of -31 dB, and an IF return loss of -26 dB. The RF-IF isolation is -57 dB. Also, a conversion gain is 8.9 dB through output amplifier. The total on-chip down-converter is implanted in 2.56${\times}$1.07 mm$^2$ of chip area.

노인의 장애물 보행 시 장애물 높이에 의한 압력중심 이동시간의 차이 (Time Difference of the COP Displacement according Obstacle Height during Obstacle Crossing in Older Adults)

  • 박설;김경;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권2호
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: This study examined the difference in the center of pressure (COP) displacement time in older adults according to the obstacle height during stance at each sub.phase when crossing obstacles. Methods: Fifteen older adults were enrolled in this study (${\geq}65$ years of age). The F-scan was used to measure the COP displacement time when crossing a 0, 10 and 40cm obstacle, and the stance phase was divided into 4 sub-phases according to the foot contact pattern. Results: During the stance phase, the COP displacement time increased with increasing obstacle height. During the mid-stance, terminal stance and pre-swing except for the loading response, there were significant differences in the COP displacement time according to the obstacle height. Conclusion: This study suggests that older adults show differences in the COP displacement time according to the stance sub-phase while crossing obstacles, and they use different mechanisms according the sub-phases to maintain balance during obstacle crossing.

용존공기부상(DAF) 공정을 이용한 생물학적 플록의 부상분리 (Flotation Separation of Biological Floc Using the Dissolved Air Flotation Process)

  • 곽동희;김성진;임영환
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.649-655
    • /
    • 2004
  • The behavior of biological particles in DAF (dissolved air flotation) process was analyzed by employing PBT (Population balance theory). After decline growth phase of activated sludge, the value of the initial collision-attachment efficiency was increased over than 0.35 corresponding relatively high value in the whole life cycle of microorganism. For practical application of DAF as a solid separation process. It is desirable that microbial particles should be operated to perform high solid removal efficiency in biological wastewater treatment.