• 제목/요약/키워드: Phantom of abdomen

검색결과 64건 처리시간 0.022초

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구 (Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen)

  • 박창희
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

Whole Abdomen CT촬영 시 차폐 재료에 따른 생식선 선량 감쇠 효과 (The Effects of Reducing a Dose on the Genital Gland at a CT Scan on the Whole Abdomen According to the Shielding Material)

  • 강은보;박철우
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.419-425
    • /
    • 2016
  • whole abdomen CT촬영에서 표재성 장기에 해당하는 생식선 부위의 선량을 줄이고 화질에 영향을 적게 주기 위한 차폐재를 제작하여 유용성을 확인하였다. 기존의 bismuth 재질과 비슷한 효과를 가지는 silicone 22 mm, aluminum 7.3 mm를 제작하였다. non shield, bismuth, silicone 22 mm, aluminum 7.3 mm 차폐재를 이용하여 생식선의 피폭 선량 감쇠, 영상의 CT number와 noise 변화, AAPM 팬텀에서 CT number, noise, uniformity를 측정하여 비교 실험하였다. 결과에서 bismuth 29.96%, silicone 22 mm 13.10%, aluminum 7.3 mm 18.27%로 피폭 선량이 감소되었다. 그러나 bismuth 재질의 경우 영상의 CT number 변화가 크고, AAPM 팬텀 영상검사 uniformity 항목에서 부적합으로 측정되어 생식선과 같은 표재성 장기에서 화질 변화가 큰 것으로 나타났다. 생식선과 같은 표재성 장기의 경우 silicone 22 mm, aluminum 7.3 mm의 차폐재를 사용한다면 화질 변화를 줄이면서 방사선 피폭을 줄이는데 도움이 될 것이라 판단된다.

CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구 (Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation)

  • 공효금;이기백
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과 (Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning)

  • 이종석;권대철;유병규
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.225-231
    • /
    • 2009
  • CT검사에 따른 방사선 선량의 유해성에 대한 관심이 고조되고 있어, 고정관전류기법과 AEC(automatic exposure control)를 적용하여 선량의 감소 효과를 비교하였다. 64MDCT를 이용하여 인체조직등가물질 팬텀으로 흉부 및 복부 부위를 고정관전류기법과 AEC를 적용하여 CTDIvol과 DLP를 비교하였고, 영상의 평가는 관심영역으로 CT감약계수와 노이즈를 측정하여 비교하였다. 흉부에서 고정관전류기법과 AEC적용에 따른 선량감소 효과는 CTDIvol 35.2%, DLP 49.3%, 복부에서는 CTDIvol 5.9%, DLP 3.2% 감소 효과가 있었다. CT검사에서 자동노출장치인 AEC를 이용하여 선량의 감소효과가 있다. CT 검사에 따른 환자의 피폭선량을 줄이기 위해서는 AEC를 이용하여야 한다.

호흡에 의한 내부 움직임의 영향이 있는 간에서의 실험적 선량 측정 (Dose perturbation measurements during the liver treatment with internal organ motion: Mathematical modeling and Experimental simulation)

  • 정진범;김연래;정원균;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.115-118
    • /
    • 2004
  • 우리의 연구는 호흡에 의해 움직임의 영향을 받는 장기 및 종양에 대해서 조사된 선량분포를 측정하는 것이다. 이 연구를 수행하기 위해, 사전연구로 이전에 발표된 논문을 토대로 호흡에 의해 장기 및 종양의 움직임 변위를 조사하였다. 그리고 조사된 데이터를 활용하여 호흡에 따른 움직임을 구동 시스템을 적용하여 구현하였다. 내부 움직임에 의한 선량분포의 변화를 측정하기 위해서 이 구동 팬톰 시스템을 사용하였다. 이 결과로부터 호흡에 환자의 조사되는 선량분포의 부정확 정도를 평가할 수 있었다.

  • PDF

Performing angiographic intervention with a femoral entry shield: Element analysis microscopy and hand dose reduction for interventional radiologist

  • Law, Martin;Ng, Dickon H.L.;Yoon, Do-Kun;Djeng, Shih-Kien
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1318-1322
    • /
    • 2021
  • To unveil and delineate the elements applicable to the radiation protection of a femoral entry shield, calculate its mass attenuation coefficient, and demonstrate its dose reduction efficacy for interventional radiologist performing transarterial embolization (TAE) of ruptured hepatocellular carcinoma (rHCC). The lead equivalency of the shield was firstly validated. Electron microscopy was used to confirm the femoral entry shield being lead-free and to analyze the elemental content, with which the mass attenuation coefficient of the shield was calculated. An adult phantom, irradiated at the upper abdomen to simulate the TAE of rHCC, was used together with a dosimeter attached to the palm of a hand phantom. The dose rates at the hand phantom were measured, with the rHCC clinical protocol, without and with the femoral entry shield placed over the right femoral access site of the adult phantom. Without using the shield, the average hand dose rate was measured to be 0.325 µSv/sec. While using the shield, it was determined to be 0.110 µSv/sec. There was significant 66% dose reduction to the hand dose of IRs performing angiographic intervention with the femoral entry shield.

Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가 (Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom)

  • 김가중;배석환;임창선;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제34권3호
    • /
    • pp.137-143
    • /
    • 2009
  • 본 연구는 호흡에 따라 움직임이 큰 흉부나 복부 장기의 방사선 수술에 적용되는 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성을 평가하였다. $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가를 위해 금침이 삽입된 움직임 Phantom을 이용하였고, Phantom은 아크릴 볼이 들어 있는 정육면체에 Radiochromic 필름을 삽입하여 가상의 치료용적인 아크릴 볼에 21 Gy, 70% 등선량곡선으로 처방하였다. 고정된 Phantom의 금침추적방법과 움직임 Phantom의 $Synchrony^{TM}$ 호흡추적 방법으로 나누어 각각 5회 측정한 정확성 평가는 고정된 Phantom 추적 시 총 에러는 $0.0195{\sim}0.652mm$, 총 에러 평균은 0.3926 mm로 나타났으며, 움직임 Phantom을 이용한 $Synchrony^{TM}$ 호흡 추적 방법의 결과로 총 에러는 $0.4405{\sim}0.7665mm$, 총 에러 평균은 0.5673 mm로 나타나 두 방법에 유의한 차이가 없었다. 본 연구를 통해 사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치의 정확성을 평가하였으며 체부의 방사선 수술 적용 시 그 유용성을 확인할수 있었다.

Exposure Index변화에 따른 Image Quality와 Effective dose에 대한 연구: a Monte Carlo Simulation Study (Research on Image Quality and Effective dose by Exposure Index Variation)

  • 김현수;정재호;이종웅
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.63-69
    • /
    • 2013
  • 평판 검출기(flat-panel detector)는 필름-스크린 시스템과 비교하여 넓은 범위의 노출지수(dynamic range)를 갖게 된다. 평판 검출기를 대상으로 임상에서 일반적으로 사용하고 있는 Abdomen supine 노출 조건인 81kV에 20mAs를 기준으로 전신형 팬텀 whole body human phantom PBU-50 (Kyoto, kagaku, Japan)을 모의 환자로 화질평가와 피폭선량측면에서 비교 연구하였다. PSNR값이 30dB이상으로 판독 가능한 영상의 kV변화에 따른 DAP값은 약 19.6배 차이를 나타냈다. 또한 kV변화에 따른 유효선량을 ICRP 103을 기준으로 비교한 결과 방사선에 의한 확률적 영향이 증가함을 알 수 있었다. 방사선검사자의 지속적인 교육 및 지도를 통한 우리나라에 맞는 디지털 방사선 Technical chart를 마련하여 양질의 영상과 환자피폭선량에 대한 기준 선량을 마련해야 할 것이다.