• 제목/요약/키워드: Petroleum facilities

검색결과 69건 처리시간 0.026초

발생원 유형에 따른 공기 중 휘발성 유기화합물의 비산배출 특성 평가 (Evaluation of Fugitive Emission Characteristics of Airborne Volatile Organic Compounds from Different Source Categories)

  • 백성옥;김미현;서영교
    • 한국대기환경학회지
    • /
    • 제19권4호
    • /
    • pp.363-376
    • /
    • 2003
  • In this study, the fugitive emission characteristics of airborne volatile organic compounds from different source categories were evaluated with respect to the concentrations measured in the vicinity of the sources. A total of 22 different sources were investigated, including gasoline storage and filling stations, painting spray booth, laundry, printing officer, textile industries, and a number of environmental sanitary facilities such as landfill, wastewater treatment and incineration plants. The target VOCs included 83 individual compounds, which were determined by adsorption sampling and thermal desorption coupled with GC/MS analysis. Overall, the aliphatic compounds appeared to be the most abundant class of compounds in terms of their concentrations, followed by aromatic, and halogenated hydrocarbons. As a single compound, however, toluene was the most abundant one, explaining 11% of the total VOC concentrations as an average of all the dataset. Among source categories, petroleum associated sources such as gasoline storage/filling stations, and laundry factory were identified as the most significant sources of aliphatic hydrocarbons, while aromatic VOCs were dominantly emitted from the sources handling organic solvents, such as painting booth, printing offices, and textile dyeing processes. However. there was no apparent pattern in terms of the contributions of eath group to the total VOCs concentrations in environmental sanitary facilities. It was also found that the activated carbon adsorption tower installed for the VOC emission control in some facilities do not show any effective performances, which may result in the increased VOC levels in the ambient atmosphere.

LNG충전시설의 위험도 표현에 관한 연구 (A Study on Quantitative Risk Presentation of LNG Station)

  • 고재욱;유진환;김범수;이헌석;김민섭
    • 한국가스학회지
    • /
    • 제13권1호
    • /
    • pp.61-67
    • /
    • 2009
  • 국내에는 가스를 사용하는 에너지 산업시설(저장시설, 고압가스 배관, 충전소, 탱크로리 등)이 전국에 산재해 있다. 이러한 대형 가스 시설에서는 화재, 폭발 및 유독물질 누출 등 중대사고가 발생할 수 있다. 또한 대기오염을 줄이기 위한 천연가스자동차의 보급으로 LNG(Liquefied Natural Gas), CNG(Compressed Natural Gas) 충전소의 보급이 늘어나고 있는 추세이다. 부천에서 발생한 LPG(Liquefied Petroleum Gas) 충전소의 대형가스사고 이후 충전소의 설치는 많은 어려움이 따른다. 따라서 이 연구에서는 LCNG/LNG 복합충전소를 연구대상으로 선정하고 기존의 정성적 위험성평가의 결과를 토대로 정량적인 위험성 평가를 표현하고, HSE(Health and Safety Executive) 기준과 비교를 통한 위험성을 확인하고자 한다.

  • PDF

동북아시아 국가의 석유정제설비의 상대적 효율성 분석 (A Study on the Analysis of the Relative Efficiency of Northeast Asian Country's oil Refinery Facilities)

  • 이충배;김정환;강효원
    • 통상정보연구
    • /
    • 제14권3호
    • /
    • pp.209-227
    • /
    • 2012
  • 글로벌 금융위기의 진원지인 동북아시아 지역은 전통적으로 석유의 생산 및 소비 불균형이 심화된 지역이며, 최근에는 급증하는 석유거래로 인해 저장 및 수송설비의 부족현상까지 겪고 있어 안정적 석유 공급을 위협하고 있다. 따라서 동북아시아 지역 내 독립적인 석유물류허브 기능을 갖춘 시설과 석유거래의 기능까지 담당할 수 있는 시장의 형성이 요구되고 있다. 본 연구에서는 동북아 지역의 석유물류허브 구축 후보 국가를 대상으로 한 석유산업 관련 설비인 정제시설의 정태적 및 동태적 효율성 분석을 통해 시사점을 도출하였다. 동북아 역내 주요 국가들의 석유정제설비의 효율성은 우리나라가 가장 높은 것으로 나타났으며 우리나라가 동북아시아 지역의 석유물류거점의 역할을 수행하기 위해서는 정부의 적극적인 정책지원이 필요하다.

  • PDF

유류오염지역의 지하수 수질특성 및 동절기 토양경작법의 온도보전을 위한 현장사례 연구 (The Characteristics of Groundwater and a Field Test for Thermal Insulation of Landfarming of Petroleum Contaminated Soil in Winter Season)

  • 조장환;김순흠;안종익;이윤오;최상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권5호
    • /
    • pp.7-14
    • /
    • 2013
  • The objectives of this study were to identify the characteristics of groundwater in the petroleum contaminated site and to evaluate the applicability of house-type landfarm facilities heated with briquette stoves in winter season. The six monitoring wells were installed at the site where pH, dissolved oxygen, and temperature were all measured. Also groundwater contaminants, benzene, toluene, ethylbenzene, xylene and total petroleum hydrocarbon, were analyzed twice. House-type two landfarm facilities ($12m{\times}40m{\times}4.8m$) each installed with four briquette stoves were constructed. During four rounds treatment process, VOCs, moisture, temperature were monitored and soil contaminants were analyzed. The pH was 6.37 and considered subacid and DO was measured to be 3.12 mg/L. The temperature of groundwater was measured to be $9.48^{\circ}C$. The groundwater contaminants were detected only in the monitoring wells within the contaminated area or close to it showing that the groundwater contaminated area was similar to the soil contaminated area. During the landfarm process, 73.3% of VOCs concentration in interior gas was decreased and moisture was lowered from 17.7% to 13.4%. In the morning, at 8:00 am, the temperature was decreased showing soil ($5.5^{\circ}C$) > interior ($4.8^{\circ}C$) > exterior ($3.5^{\circ}C$). In the afternoon, at 2:00 pm, the temperature was soil ($8.6^{\circ}C$) < interior ($9.9^{\circ}C$) < exterior ($11.5^{\circ}C$) with solar radiation. The temperature difference between interior and exterior was $0.7^{\circ}C$ in the morning, but it was $1.6^{\circ}C$ in the afternoon. A total of 130 days were taken for four round landfarm processes. Each process was completed within 33 days showing 80% of cleanup efficiency ($1^{st}$ order dissipation rate(k) = 0.1771).

CONTAMINANT LEACHABILITY FROM UTILIZED WASTES IN GEOSYSTEMS

  • Inyang Hilary I.
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 INTERNATIONAL SYMPOSIUM ON SOIL & GROUNDWATER ENVIRONMENT
    • /
    • pp.5-21
    • /
    • 2005
  • Urbanization rates of population range from about 1% in the developed countries to about 4% in developing countries. For a global population that may reach 10 billion within the next 40 years, pressure has arisen for an increase in the large-scale use of wastes and byproducts in construction. Ironically, most of the wastes that need to be recycled are generated in large cities where the need for constructed facilities to serve large population is high. Waste and recycled materials (WRM) that are used in construction are required to satisfy material strength, durability and contaminant teachability requirements. These materials exhibit a wide variety of characteristics owing to the diversity of industrial processes through which they are produced. Several laboratory-based investigations have been conducted to assess the pollution potential and load bearing capacity of materials such as petroleum-contaminated soils, coal combustion ash, flue-gas desulphurization gypsum and foundry sand. For full-scale systems, although environmental pollution potential and structural integrity of constructed facilities that incorporate WRM are interrelated, comprehensive schemes have not been developed for integrated assessment of the relevant field-scale performance factors. In this presentation, a framework for such an assessment is proposed and presented in the form of a flowchart. The proposed scheme enables economic, environmental, worker safety and engineering factors to be addressed in a number of sequential steps. Quantitative methods and test protocols that have been developed can be incorporated into the proposed scheme for assessing the feasibility of using WRM as partial or full substitutes for earthen highway materials in the field.

  • PDF

A Study on Estimation of Liquid Leakage Using Wide Angle Camera Based Angled of Arrival Algorithm in Bio Plant

  • Shin, Jaekwon;Mariappan, Vinayagam;Woo, Deokgun;Lee, Junghoon;Lee, Jisung;Kim, Minsoo;Kim, Jintae
    • International journal of advanced smart convergence
    • /
    • 제7권1호
    • /
    • pp.1-6
    • /
    • 2018
  • In addition to the instability of energy import costs caused by the depletion of petroleum resources, which is a representative energy resource, and the strengthening of various regulations such as the convention on climate change, the plant for bio energy production, which is being watched as the next generation energy, and became subject of various complaints. In order to solve this problem, the bio-plant is underground and the ground is parked, making the convenience and accessibility of citizens more and more accessible. In this situation, the development of bioenergy production technology also increases the risk factor in bioenergy production process. Accordingly this paper explains method about apply the wide angle camera based AOA algorithm to the bio plant to prevent the accidents from spreading due to the lack of facilities and safety devices and the aging of the facilities and suggests a technique that can quickly identify the location and direction when it occurs.

해양 시추시스템 구성요소에 대한 이해 및 동향분석 (Understanding of Offshore Drilling System and Trend Analysis)

  • 우남섭;권재기;박종명;김상식;김영주
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.33-38
    • /
    • 2013
  • 해상에서의 시추작업은 해저면을 통해서 시추되는 유정에서 이루어지는 일련의 기계적 프로세스라 할 수 있다. 해양 시추설비는 해저에 매장된 석유나 가스의 매장량 확인을 위한 테스트 유정(well)과 이를 경제성 있는 생산용 유정으로 만들기 위해 사용되는 시설로 해양에서의 시추작업은 대부분 타 지역으로의 이동을 위해 이동식으로 제작되며, 작업 해역의 수심에 따라 크게 리그(jack-up, semi-submersible)와 드릴십(drillship)으로 구분할 수 있다. 최근에는 석유와 가스의 개발을 위한 시추작업이 급진적으로 심해로 옮겨가고 있으며 작업 가능 수심이 3,000 m에 이르고 있다. 본 논문에서는 이러한 해상 시추설비에 탑재되는 대표적 해양플랜트 기자재인 시추시스템을 소개하고 최근의 기술개발 동향을 알아보고자 한다.

특정토양오염관리대상시설의 최적 관리방안에 관한 연구 (Optimum Management Plan for Soil Contamination Facilities)

  • 박재수;김기호;김해금;최상일
    • 한국토양비료학회지
    • /
    • 제45권2호
    • /
    • pp.293-300
    • /
    • 2012
  • 본 연구에서는 국내 한 토양관련전문기관에서 실시한 석유류저장시설에 대한 법정누출검사와 자체정밀조사에서 실제 특정토양오염관리대상시설로부터 오염물질이 누출되는 기준으로는 25.7%, 저장탱크의 결함 등으로 부적합 경우를 포함하면 53.6%가 부적합으로 나타나 환경부의 누출검사 통계의 평균 부적합률 3.1%와는 현저한 차이가 있으며, 누출검사를 실시하는 동기와 점검방식 등에 따른 부적합률이 매우 다르게 나타났다. 또한, 제작 당시에 발생된 결함이 남아 누출의 잠재적 요인이 되고 있는 탱크가 약 20%에 이르고 있으며, 시설의 사용년수 경과에 따른 조사에서는 설치 후 10년 이하 시설의 부적합률이 상대적으로 높게 나타났다. 이와 같은 결과들을 토대로 도출한 특정토양오염관리대상시설에 대한 최적의 사후관리방안은 다음과 같다. 본 연구 결과를 토대로 한 법정누출검사의 이상적인 부적합률은 직접법의 경우 53.6%, 간접법의 경우 30.7%로서 현재의 부적합률과는 많은 차이가 있으며 이는 누출이 되더라도 이를 감지하는 확률이 떨어지는 간접법과, 누출이 없더라도 결함 등으로 부적합으로 판정되는 직접법 등 검사방식에서 비롯된 원천적 차이와, 검사자의 부정 또는 부실검사 등 운용상의 문제로부터 야기되는 결과로 판단되며, 이를 개선하기 위해서는 현재 누출의 감지율이 극히 낮은 가압법 등의 검사방식은 전문적인 실험을 통해 실제 누출을 감지할 수 있는 수준의 시험기준을 마련하는 한편, 토양관련전문기관 및 이에 소속된 검사자에 대한 교육과 검사결과에 대한 사후검증을 통해 부실 부정검사가 이루어지지 않도록 해야 한다. 설치경과년수 10년 이하의 시설이 업소단위의 부적합률, 저장탱크 및 배관계통의 시설단위 부적합률에서 공히 상대적으로 높은데 이는 부실 시공 등으로 인한 문제가 초기에 집중적으로 발생하는 결과로 보이며, 이와 같은 문제를 해소하기 위해서는 신규 시설에 대한 관리제도를 개선하는 한편, 특정토양오염관리대상시설을 설치한 후 10년이 경과하였을 때에는 6개월 이내 누출검사를 받도록 한 현재의 토양환경보전법 시행령 제8조제1항제2호의 규정은 설치 후 5년이 경과한 시점으로 변경하는 방안을 고려해야 한다. 시설을 설치한 후 10년 이상 경과하면 업소단위의 부적합률은 년평균 약 1.4%씩, 시설로부터 누출 발생률은 약 0.25% 씩 증가하고 있는데, 누출검사의 주기는 새로이 발생되는 누출로 인한 환경적 피해와 복구비용, 누출검사에 따른 직접적인 경제적 비용, 행정규제에 따른 국가차원의 득실을 고려하여 결정하는 것이 타당하나 누출검사와 정화에 따른 직접적인 비용만을 비교하여 결정하는 것도 하나의 방안이 될 수 있다. 예를들어, 누출검사 비용을 업소당 150만원, 오염된 업소의 토양정화비용을 1억원으로 하면 경제성 관점에서의 바람직한 점검주기는 약 6년이 된다. 그러나, 업소에 설치된 저장탱크와 배관계통의 품질은 거의 동등하여 하나의 탱크나 배관에서 문제가 발생되면 나머지 시설에서도 순차적으로 유사한 문제가 발생되고, 시설이 내구연한에 도래할수록 그 경향이 뚜렷해지므로, 일련의 시설계통에서 누출이 발생된 경우에는 검사주기를 점차 단축하여 적용하는 것을 고려할 필요가 있다. 본 연구에서 검사방식에 따른 점검결과를 보면, 업소단위의 부적합률에서는 58.9%와 22.5%, 저장탱크에 대한 검사에서 23.1%와 1.6%, 주입배관의 경우 4.1%와 0.5%, 주유 배관의 경우 5.5%와 4.1% 등 직접법으로 점검한 경우가 간접법에 비해 현저히 높아, 간접법으로만 점검을 지속하는 경우 그 차이만큼 누출을 방치하는 결과가 초래되는 것으로 나타났다. 이와 같은 문제를 해소하기 위해서는, 일정 주기마다 반드시 직접법으로 점검을 실시토록 하거나 직접법과 간접법을 교차하여 적용토록 개선할 필요가 있다. 비파괴검사에서 부적합 된 저장탱크를 결함의 유형별 분류한 결과 기공 또는 미용접 등 제작하는 과정에서 발생되는 선천적 결함으로 부적합 된 것이 약 20%에 이르고 있는데, 이는 시설의 노후화로 인한 두께미달과 국부부식 등의 후천적 결함에 의한 불합격률 보다 높은 것이다. 이와 같은 선천적 결함은 당해 저장탱크를 제작할 당시의 기술수준과 점검제도 등에서 기인한 것으로 이를 해소하기 위해서는 차기의 누출검사를 반드시 직접법으로 실시하여 원천적 결함을 보수하도록 하고, 현재의 위험물안전관리법에 의한 탱크 성능시험기준을 개정하여 새로이 설치되는 저장탱크는 모두 비파괴시험을 실시하여 제작과정에서 발생된 결함이 제거되도록 하여야 한다. 검사를 실시하게 된 동기를 자체정밀조사와 법정누출검사로 분류하여 평가한 결과, 자체정밀조사에서의 부적합률이 법정누출검사에서의 부적합률에 비해 현저히 높게 나타났는데, 검사결과 부적합 되는 경우 수반되는 2차적인 부담을 회피하려는 심리가 크게 작용하고 있는 것으로 판단된다. 즉, 법정누출검사에서 부적합 되는 경우 행정관서로부터 받게 되는 시설에 대한 보완 및 재검사, 토양정밀조사 및 오염토양 정화 등 일련의 조치를 회피하기 위하여 검사를 취소하거나 즉시 보수를 행하여 재검사를 받도록 함으로서 검사결과가 왜곡되고 있다. 이와 같은 문제를 해결하기 위해서는 법정누출검사 결과 부적합된 시설에 대한 시정명령을 시설 보완과 재검사로 한정하여 특정토양오염관리대상시설의 소유자가 사실적으로 점검할 수 있도록 하고, 시설로부터 저장물질의 누출에 의한 부지의 오염은 소유주가 상황을 고려하여 자발적으로 사후조치를 하게 하거나 차기토양오염도 검사를 통해 오염여부를 확인하도록 부담을 완화 할 필요가 있다. 특정토양오염관리대상시설은 설치시기가 오래된 것 일수록 높은 부적합률을 나타내고 있다. 철판의 부식속도를 시설의 설치경과년수에 따른 평균최소두께의 추이에서 확인된 $0.1mm\;yr^{-i}$을 적용할 경우, 6 mm의 철판을 사용한 탱크는 위험물안전관리법상 탱크의 최소두께 (3.2 mm)에 이르기까지 이론상 내구연한은 28년으로서, 2012년 기준 내구연한을 초과한 시설이 7.3%에 이르고 있으며, 동시기에 설치된 주유배관 (표준두께 3.7 mm)의 경우 이론상의 잔존두께는 0.9 mm에 불과하다는 결론이다. 이와 같이 한계수명에 다다른 시설이나 이론상 내구연한을 초과한 시설에 대하여는 조속히 국가적 차원의 조사를 통해 그 실태를 파악하고 그 결과에 따라 폐쇄 또는 Upgrade 방안을 강구해야 한다.

여수해역에 있어서 기름유출에 대한 방제대책 수립에 관한 연구 (A Study on the Establishment of Oil Spill Response Measures in Yeosu Waters)

  • 국승기;윤종휘;김원돈;이상호
    • 해양환경안전학회지
    • /
    • 제7권2호
    • /
    • pp.23-37
    • /
    • 2001
  • Marine environment has been polluted and damaged by many sources such as industrial waste, natural seepage, oil spill and offshore production etc. Among them, oil spill from oil tankers is one of most harmful sources to marine lives as its input amount is huge at a limited area for short period. In Korea, the port of Yeosu is known to be very vulnerable to oil spill with large amount of petroleum transported across the harbour. In this regards, the author analyzed and reviewed marine environment and appropriate response to marine oil spill at this area. For these purposes, oceanographic and meteorologic features as well as regional characteristics of harbor facilities, shipping routes, marine traffic and fisheries were investigated, also traffic densities were analyzed in order to check marine accident probabilities making direct observations for 72 hours visual1y and by portable radar.

  • PDF

An Expert System for Monitoring and Control of an Oil Production Facility

  • Uraikul, Varanon;Chan, Christine W.;Asghari, Koorosh;Monea, Michael J.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1169-1172
    • /
    • 2002
  • This paper presents the development of an expert system for monitoring and control of an oil production facility. The objectives of developing an expert system for the oil production facility are to monitor the Important processing parameters in different sections of the facilities and to control battery operations in real time. By providing consistent, fast, and reliable decision support to operators, the expert system can be used for automated monitoring and control of a petroleum production facility located south of Regina in Saskatchewan, Canada. The system was implemented in Visual Basic 6.0.

  • PDF