• 제목/요약/키워드: Pet Hospital

검색결과 564건 처리시간 0.024초

Synthetic approaches toward [18F]Fluoromisonidazole as a hypoxia imaging maker

  • Kwon, Young-Do;Lim, Seok Tae;Jeong, Hwan-Jeong;Sohn, Myung-Hee;Kim, Hee-Kwon
    • 대한방사성의약품학회지
    • /
    • 제1권1호
    • /
    • pp.9-14
    • /
    • 2015
  • Hypoxia has been shown in many tumors because of a reduced oxygen condition. A useful approach to detect hypoxia is to use molecular imaging. Positron emission tomography (PET), one of the biomedical molecular imaging tools, is the most common non-invasive technique for providing information about physiological and biological events such as diseases. In order to use the PET technique for healthcare, promising molecular probes such as PET tracers required. [$^{18}F$]Fluoromisonidazole ([$^{18}F$]FMISO) is the most widely used in PET tracers for hypoxia. In this review, major developments of the synthetic method of [$^{18}F$]FMISO are discussed.

팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가 (Evaluation of Dosimetry and Image of Very Low Dose CT Attenuation Correction for Pediatric PET/CT: Phantom Study)

  • 반영각;김정열;박훈희;강천구;임한상;이창호
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.53-59
    • /
    • 2011
  • 최근 PET/CT 검사는 성인 암환자뿐만 아니라 소아 암환자에게도 많이 적용하고 있다. 그러나 소아 환자의 경우 성인에 비하여 방사성 감수성이 높아 피폭선량의 관리를 필요로 하고 있다. 그러므로 본 저자는 팬텀을 이용하여 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상을 평가하였다. 3대의 PET/CT 장비 (Discovery STe, BiographTruepoint 40, Discovery 600)로 소아 사이즈의 아크릴 팬텀과 이온 챔버 선량계 (Unfous Xi CT, Sweden)를 이용하여 CT 영상획득 조건 (10, 20, 40, 80, 100, 160 mA; 80, 100, 120, 140 kVp)을 변화시켜 심부선량과 $CTDI_{vol}$ 값을 평가하였다. 그리고 NEMA PET Phantom$^{TM}$을 이용하여 같은 CT 조건으로 PET 영상을 획득하여 감쇄보정 된 각 PET 영상을 SUV 값과 신호 대 잡음 비로 평가하였다. 심부선량은 일반적으로 소아복부 CT 조건 (100 kVp, 100 mA) 보다 최소 CT 조건 (80 kVp, 10 mA)에서의 심부선량은 약 92% 감소 되었고, $CTDI_{vol}$ 값은 약 88% 감소되었다. 각 CT 조건에 따라 감쇄 보정된 PET 영상은 SUV 값에 변화가 없었고, 신호 대 잡음 비도 영향을 받지 않았다. 팬텀을 이용한 소아 PET/CT 실험시 최저 선량 CT 조건 (80 kVp, 10 mA) 을 적용하여 감쇄보정을 진행한 PET 영상에는 영향 없었다. 소아 환자의 PET/CT 검사 시 CT 의 진단이 필요 없는 PET 영상만을 획득하고자 한다면, 소아 환자의 신체에 적절히 적용한 최저선량 CT 을 감쇄보정을 하여, 유효 선량을 성인에 비하여 약 90% 이상 감소시켜 피폭 선량 저감에 도움이 될 것이다.

  • PDF

PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차 (A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols)

  • 김상언;곽동우;박현수;방성애;박영재;이인원
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.7-10
    • /
    • 2013
  • PET/CT 검사에서 피검자의 호흡에 의한 움직임은 PET과 CT의 정합오차를 유발하여 영상의 질 저하와 판독의 정확도를 떨어뜨리는 원인이 된다. PET/CT 검사에서 CT 영상 획득 시 자유호흡과 호기 시 잠시 멈춤 상태에서 획득하는 두 가지 호흡법을 이용하여 각 호흡법이 PET과 CT 영상의 정합결과에 끼치는 영향을 평가하였다. 환자 200명을 대상으로 두 집단으로 나누어 CT 영상 획득 시 평소대로 호흡하거나 호기 시 멈추도록 지도하였다. PET과 CT가 정합된 전신영상 관상단면에서 횡경막-간 경계의 정합오차를 길이로 측정하였으며 각 호흡법에 따른 성별, 연령, 상병의 정합오차를 비교하였다. 자유호흡과 호기 시 잠시 멈춤 상태에서 정합오차의 차이는 통계적으로 유의한 차이가 없었으며 호흡법에 따른 정합차이가 99%이상이 5 mm이하였다. 호흡법, 연령, 상병에 따른 정합오차의 차이가 통계적으로 유의한 차이가 없었다. 본 연구를 통하여 PET/CT 검사시 호흡법에 의한 PET와 CT영상의 정합차이가 없음을 증명하였다. 호흡에 의한 motion artifact를 줄이기 위해서는 더 많은 연구가 진행되어야 할 것이다.

  • PDF

간세포암종과 혼합성 간세포암종-담관암종에서 다위상 전산단층촬영술 소견과 18F-FDG PET/CT에서 섭취율 차이에 대한 분석 (Usefulness of 18F-FDG PET/CT and Multiphase CT in the Differential Diagnosis of Hepatocellular Carcinoma and Combined Hepatocellular Carcinoma-Cholangiocarcinoma)

  • 박재춘;박정구;정규식;강희;전성민
    • 대한영상의학회지
    • /
    • 제81권6호
    • /
    • pp.1424-1435
    • /
    • 2020
  • 목적 간세포암종과 혼합성 간세포암종-담관암종의 다위상 전산단층촬영술 소견과 18F-fluorodeoxyglucose 양전자방출단층촬영(이하 FDG PET/CT)에서 섭취율 차이를 연구하여 이들의 감별 진단에 유용성이 있는지를 알아보고자 하였다. 대상과 방법 2007년 1월에서 2016년 4월까지 조직학적으로 간세포성 암종으로 진단된 84명과 혼합성 간세포암종-담관암종으로 진단된 9명의 환자를 대상으로 하였다. 조영증강 양상은 유형 I (동맥기 조영증강과 지연기 조영유실), 유형 II (지연기 조영유실이 없는 동맥기 조영증강), 유형 III (저혈관성 병변, 침투성 양상 혹은 변연부 조영증강)로 구분하였고, PET/CT 소견은 FDG 섭취 여부에 따라서 양성과 음성으로 분류하였다. 결과 혼합성 간세포암종-담관암종(89%)은 간세포암종(61%)보다 PET/CT 섭취 양성률이 높았으나 통계적으로 유의한 차이는 보이지 않았다(p = 0.095). 유형 I 조영증강양상을 보이는 58개의 간세포암종 중 37예(64%)가 PET/CT에서 양성이었다. 유형 II 조영증강양상을 보이는 19예 중 간세포암종 3예(21%)에서 PET/CT에서 양성을 보였고 혼합 간세포암종-담관암종 4예(80%)에서 PET/CT 양성을 보였다. 유형 II 조영증강양상을 보이는 경우 혼합 간세포암-담관암종이 간세포암종보다 PET/CT 양성률이 유의하게 높았다(p = 0.020). 유형 III 조영증강 양상을 보이는 16예 중 간세포암 11예(91.6%), 혼합 간세포암-담관암종 4예(100%)에서 PET/CT 양성을 보였다. 유형 III 조영증강양상을 보이는 경우 간세포암과 혼합 간세포암-담관암종의 PET/CT 양성률의 유의한 차이는 보이지 않았다. 결론 유형 II 조영증강 양상을 보이는 경우 간세포암종과 혼합성 간세포암종-담관암종의 감별진단에 전산단층촬영술과 병행하는 18F-FDG PET/CT가 도움이 될 것으로 보인다.

N-13 암모니아 PET 동적영상과 요소분석을 이용한 심근 혈류량 정량화 방법 개발 (Quantification of myocardial blood low using dynamic N-13 ammonia PET and actor analysis)

  • 김준영;최용;임기천;최연성;이경한;김상은;김영진;김병태
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.575-578
    • /
    • 1997
  • Myocardial blood low (MBF) in human can be noninvasively quantified using dynamic N-13 ammonia PET and two-compartment tracer kinetic model. In this study, factor analysis was used to extract the "pure" blood-pool time-activity curves (TACs) and to generate actor images. ive human N-13 ammonia PET dynamic studies were obtained. Three actors and their corresponding actor images were extracted rom each study. The accuracy of MBF estimated by the actor analysis (FA/FA MBF) was examined by comparing to the values estimated using the conventional ROI method (ROI/ROI MBF). MBF obtained by the actor analysis linearly correlated with MBF obtained by the ROI method (slope=0.98, r=0.91). Input unctions obtained by the two methods agreed well. In conclusion, MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and actor analysis. This method is simple and acurate and can measure MBF without blood sampling, ROI drawing nor spillover correction.

  • PDF

Maximum standardized uptake value at pre-treatment PET in estimating lung cancer progression after stereotactic body radiotherapy

  • Park, Jisun;Choi, Yunseon;Ahn, Ki Jung;Park, Sung Kwang;Cho, Heunglae;Lee, Ji Young
    • Radiation Oncology Journal
    • /
    • 제37권1호
    • /
    • pp.30-36
    • /
    • 2019
  • Purpose: This study aimed to identify the feasibility of the maximum standardized uptake value (SUVmax) on baseline 18F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) as a predictive factor for prognosis in early stage primary lung cancer treated with stereotactic body radiotherapy (SBRT). Materials and Methods: Twenty-seven T1-3N0M0 primary lung cancer patients treated with curative SBRT between 2010 and 2018 were retrospectively evaluated. Four patients (14.8%) treated with SBRT to address residual tumor after wedge resection and one patient (3.7%) with local recurrence after resection were included. The SUVmax at baseline PET/CT was assessed to determine its relationship with prognosis after SBRT. Patients were divided into two groups based on maximum SUVmax on pre-treatment FDG PET/CT, estimated by receiver operating characteristic curve. Results: The median follow-up period was 17.7 months (range, 2.3 to 60.0 months). The actuarial 2-year local control, progression-free survival (PFS), and overall survival were 80.4%, 66.0%, and 78.2%, respectively. With regard to failure patterns, 5 patients exhibited local failure (in-field failure, 18.5%), 1 (3.7%) experienced regional nodal relapse, and other 2 (7.4%) developed distant failure. SUVmax was significantly correlated with progression (p = 0.08, optimal cut-off point SUVmax > 5.1). PFS was significantly influenced by pretreatment SUVmax (SUVmax > 5.1 vs. SUVmax ≤ 5.1; p = 0.012) and T stage (T1 vs. T2-3; p = 0.012). Conclusion: SUVmax at pre-treatment FDG PET/CT demonstrated a predictive value for PFS after SBRT for lung cancer.

Prognostic Value of Restaging F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography to Predict 3-Year Post-Recurrence Survival in Patients with Recurrent Gastric Cancer after Curative Resection

  • Sung Hoon Kim;Bong-Il Song;Hae Won Kim;Kyoung Sook Won;Young-Gil Son;Seung Wan Ryu
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.829-837
    • /
    • 2020
  • Objective: The aim of this study was to investigate the prognostic value of the maximum standardized uptake value (SUVmax) measured while restaging with F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) to predict the 3-year post-recurrence survival (PRS) in patients with recurrent gastric cancer after curative surgical resection. Materials and Methods: In total, 47 patients with recurrent gastric cancer after curative resection who underwent restaging with 18F-FDG PET/CT were included. For the semiquantitative analysis, SUVmax was measured over the visually discernable 18F-FDG-avid recurrent lesions. Cox proportional-hazards regression models were used to predict the 3-year PRS. Differences in 3-year PRS were assessed with the Kaplan-Meier analysis. Results: Thirty-nine of the 47 patients (83%) expired within 3 years after recurrence in the median follow-up period of 30.3 months. In the multivariate analysis, SUVmax (p = 0.012), weight loss (p = 0.025), and neutrophil count (p = 0.006) were significant prognostic factors for 3-year PRS. The Kaplan-Meier curves demonstrated significantly poor 3-year PRS in patients with SUVmax > 5.1 than in those with SUVmax ≤ 5.1 (3-year PRS rate, 3.5% vs. 38.9%, p < 0.001). Conclusion: High SUVmax on restaging with 18F-FDG PET/CT is a poor prognostic factor for 3-year PRS. It may strengthen the role of 18F-FDG PET/CT in further stratifying the prognosis of recurrent gastric cancer.

위암에서 $^{18}F-FDG$ PET의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET in Gastric Cancer)

  • 윤미진;김태성;황희성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.39-45
    • /
    • 2008
  • PET or PET/CT detects only less than 50% of early gastric cancer and 62-98% of advanced gastric cancer. Therefore, mass screening programs are recommended for all adults over the age of 40 for early detection and early treatment of gastric cancer through endoscopy or various radiological tests. The most important step after diagnosis of gastric cancer is accurate staging, which mainly evaluates tumor resectability to avoid unnecessary surgery. Important factors that affect tumor resectability are whether the tumor can be separated from adjacent organs or important blood vessels, the extent of lymph node metastasis, presence of peritoneal metastasis, or distant organ metastasis. To evaluate the extent of local tumor invasion, anatomical imaging that has superior spatial resolution is essential. There are a few studies on prognostic significance of FDG uptake with inconsistent results between them. In spite of lower sensitivity for lymph node staging, the specificity of CT and PET are very high, and the specificity for PET tends to be higher than that for CT. Limited data published so far show that PET seems less useful in the detection of lung and bone metastasis. In the evaluation of pleural or peritoneal metastasis, PET seems very specific but insensitive as well. When FOG uptake of primary tumor is low, distant metastasis also tends to show low FDG uptake reducing its detection on PET. There are only a few data available in the evaluation of recurrence detection and treatment response using FDG PET or PET/CT.

A Novel Melanin-Targeted 18F-PFPN Positron Emission Tomography Imaging for Diagnosing Ocular and Orbital Melanoma

  • Yiyan Wang;Xinghua Wang;Jie Zhang;Xiao Zhang;Yang Cheng;Fagang Jiang
    • Korean Journal of Radiology
    • /
    • 제25권8호
    • /
    • pp.742-748
    • /
    • 2024
  • Objective: 18F-N-(2-(Diethylamino)ethyl)-5-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy) picolinamide (18F-PFPN) is a novel positron emission tomography (PET) probe designed to specifically targets melanin. This study aimed to evaluate the diagnostic feasibility of 18F-PFPN in patients with ocular or orbital melanoma. Materials and Methods: Three patients with pathologically confirmed ocular or orbital melanoma (one male, two females; age 41-59 years) were retrospectively reviewed. Each patient underwent comprehensive 18F-PFPN and 18F-fluorodeoxyglucose (18F-FDG) PET scans. The maximum standardized uptake value (SUVmax) of the lesion and the interference caused by background tissue were compared between 18F-PFPN and 18F-FDG PET imaging. In addition, the effect of intrinsic pigments in the uvea and retina on the interpretation of the results was examined. The contralateral non-tumorous eye of each patient served as a control. Results: All primary tumors (3/3) were detected using 18F-PFPN PET, while only two primary tumors were detected using 18F-FDG PET. Within each lesion, the SUVmax of 18F-PFPN was 2.6 to 8.3 times higher than that of 18F-FDG. Regarding the quality of PET imaging, the physiological uptake of 18F-FDG PET in the brain and periocular tissues limited the imaging of tumors. However, 18F-PFPN PET minimized this interference. Notably, intrinsic pigments in the uvea and retina did not cause abnormal concentrations of 18F-PFPN, as no anomalous uptake of 18F-PFPN was detected in the healthy contralateral eyes. Conclusion: Compared to 18F-FDG, 18F-PFPN demonstrated higher detection rates for ocular and orbital melanomas with minimal interference from surrounding tissues. This suggests that 18F-PFPN could be a promising clinical diagnostic tool for distinguishing malignant melanoma from benign pigmentation in ocular and orbital melanomas.

PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰 (The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT)

  • 박민수;함준철;조용인;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.35-43
    • /
    • 2012
  • CT를 기반으로 감쇠 보정이 시행되는 PET/CT 검사에서는 금속 삽입물에 의한 선속 경화 현상 (Beam Hardening Artifact)으로 인공물이 발생 된다. 이는 인접한 부위의 과대 혹은 과소 평가를 유발하는 감쇠 보정으로 인해 $^{18}F$-FDG의 섭취 변화를 가져오며 영상의 질과 비뇨 생식기 질환의 진단능을 저하시킨다. 따라서 본 연구에서는 PET/CT 영상의 질 향상을 위한 금속 인공물 저감 (Metal Artifact Reduction, MAR) algorithm 재구성방법의 유용성을 평가하고자 한다. 인공 고관절 삽입물에 대한 인공물을 평가하기 위해 SPECT/PET Phantom에 고관절 삽입물을 고정 하여 PET/CT를 진행했다. W/O MAR algorithm 영상과 MAR algorithm 영상에서 CT상에 나타나는 Bright streak, Dark streak, Metal과 Background의 영역에서의 표준화 섭취 계수(Standardized Uptake Value)의 변화를 분석하였다. 또한 본원에 내원한 고관절 전치환술을 시행한 15명의 환자에게서 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상을 비교 평가하였다. W/O MAR algorithm 영상에서 SUV는 Bright streak 영역에서는 $0.98{\pm}0.48$ g/ml, Dark streak 영역에서는 $0.88{\pm}0.02$ g/ml, Metal 영역에는 $0.24{\pm}0.16$ g/ml, Background 영역은 $0.91{\pm}0.18$ g/ml로 측정되었다. 하지만 MAR algorithm 영상에서는 Bright streak 영역에서는 $0.88{\pm}0.49$ g/ml, Dark streak 영역은 $0.63{\pm}0.21$ g/ml, Metal 영역에서는 $0.06{\pm}0.07$ g/ml, Background는 $0.90{\pm}0.02$ g/ml로 측정되었다. MAR algorithm 적용 시 SUV가 평균적으로 감소 하였으며, W/O MAR algorithm 영상에서는 Bright streak영역에서 Background 보다 높게 측정되어 false positive uptake로 나타났으나 MAR algorithm 영상에서는 Background와 비슷한 농도와 SUV가 나타났고, false positive uptake가 관찰되지 않았다. 따라서 MAR algorithm을 적용하여 인공 고관절 삽입물 주변 조직의 과대 혹은 과소 감쇠 보정으로 인한 섭취의 증가를 줄일 수 있었다. 하지만 Dark streak 영역에서의 SUV 저하를 줄이기 위한 방안은 더욱 많은 연구가 이뤄져야 할 것이다. 고관절 삽입 인공물로 인해 발생하는 Bright streak 영역에서의 false positive uptake를 감소시키고 이와 인접해 있는 비뇨 생식기 질환에 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상이 동시에 제공된다면 더욱 진단능을 향상 시킬 수 있으리라 생각된다.

  • PDF