• Title/Summary/Keyword: Pet Hospital

Search Result 556, Processing Time 0.03 seconds

Positron Emission Tomography/Computed Tomography Features of Canine Lymphoma (Positron Emission Tomography/Computed tomography를 이용한 개 림프종의 영상 평가)

  • Park, Seungjo;Kwon, Seong-young;Min, Jung-Joon;Choi, Jihye
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • In this study, the features of canine lymphoma on fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) were evaluated in three small breed dogs. In case 1, ultrasonography and CT indicated neoplastic involvement of the sternal, right axillary, submandibular, lower cervical, tracheobronchial, mesenteric, and sublumbar lymph nodes; spleen; and liver. However, intense FDG uptake on PET/CT images was detected only for the lymph nodes and spleen. No FDG uptake by the liver was detected for case 1 despite the confirmation of lymphoma by cytology. In case 2, ultrasonography and CT indicated neoplastic involvement of the axillary, mesenteric, and sublumbar lymph nodes and the spleen, while intense FDG uptake on PET/CT images was detected for the axillary and a few mesenteric lymph nodes, and the spleen. FDG uptake was additionally observed from popliteal lymph nodes, however there was no uptake by the sublumbar lymph nodes and some mesenteric lymph nodes. In case 3, neoplastic changes in the splenic, mesenteric, and sublumbar lymph nodes and spleen were suspected on ultrasonography, and lower cervical and popliteal lymph node involvements were additionally detected on PET/CT. Compared to ultrasonography, repeated PET/CT showed increased FDG uptake by the lymph nodes at an earlier stage after chemotherapy in case 3. This study illustrated the features of PET/CT in canine lymphomas and compared those to ultrasonography and CT findings. FDG uptakes were not detected from some lesions which were suspected to be neoplastic involvement in case 1 and 2. We could not clearly explain the reason of this result in the present study because cytological or histological examination was not performed for lesions that showed different results on ultrasonography, CT, and PET/CT. Further studies on the subclassification of canine lymphoma and the sensitivity and specificity of PET/CT for the detection of canine lymphoma are required. PET/CT data can provide useful information for predicting the therapeutic response at an early stage after treatment.

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

Evaluate Utility of Thyroid Cancer Discrimination by 18F-FDG PET/CT Delay Scan Images (18F-FDG PET/CT검사에서 지연영상을 이용한 갑상선암 진단의 유용성 평가)

  • Lee, Hyeon-Guck;Han, Man-Seok;Kim, Yong-Kyun;Seo, Sun-Youl;Jeon, Min-Cheol;Kim, Tae-Hyung;Hong, Seong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2958-2965
    • /
    • 2013
  • Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.

Solitary Necrotic Nodule of the Liver Mimicking Metastasis in Patient with Early Gastric Cancer : 3T MRI and PET/CT Findings (조기 위암 환자에서 전이암과 감별이 필요했던 간내 단발성 궤사성 결절: 3T MRI 및 PET/CT 소견)

  • Cho, Woo-Sun;Kim, Gi-Hyeon;Lee, Hwa-Yeon;Lee, Jong-Beum;Kwon, Gui-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.213-217
    • /
    • 2009
  • Solitary necrotic nodule (SNN) of the liver is a very uncommon benign lesion, and it is detected incidentally as a rule. It is important to differentiate SNN radiologically from various single hepatic nodules because SNN mimics hepatic metastasis, especially in staging work up of known primary malignancy. The reported imaging findings of SNN are well-defined nodule without enhancement or with subtle peripheral enhancement. There has been no report about the target-like SNN of the liver and about the imaging finding of 3T magnetic resonance imaging and positron emission tomography. We report a case of targetlike SNN of the liver, mimicking hepatic metastasis, with findings of various imaging modalities and try to find a cause of this nodule according to the pathologic and literature review.

  • PDF

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Correlation of SUV According to the Body Weight and Body Surface Area in PET/CT Imaging (PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계)

  • Park, Ju-Seon;Do, Yong-Ho;Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.44-47
    • /
    • 2013
  • Purpose: There are several methods of measuring SUV in PET/CT imaging including $SUV_{bw}$ which uses the body weight, $SUV_{bsa}$ which that uses body surface area and $SUV_{lbm}$ which uses lean body mass. Currently, Seoul National University Hospital uses $SUV_{bw}$ method which minimizes the variability. In this study, we compared and analyzed the correlation between $SUV_{bw}$ and $SUV_{bsa}$ according to patients' body mass index. Materials and Methods: Using Biograph mCT40 (Siemens, Germany), we conducted $^{18}F-FDG$ PET/CT imaging on 70 patients (41 males, 29 females; ages $58.04{\pm}12.44$). We classified the patients as underweight (BMI<20), normal weight (20$${\leq_-}$$BMI<25), overweight (25$${\leq_-}$$BMI<30), obese (30$${\leq_-}$$BMI<35) and severely obese (35$${\leq_-}$$BMI) according to the patient's sex, age and BIM. Then, bone, liver and lungs were set as ROI for calculation of maximum values of $SUV_{bw}$ and $SUV_{bsa}$, through Syngo.via VA11A analysis program. Results: Comparing the five groups divided according to the BMI by the standard differences between $SUV_{bw}$ to $SUV_{bsa}$, $SUV_{max}$ was measured to be $0.66{\pm}0.15$, $0.78{\pm}0.35$, $0.77{\pm}0.21$, $1.00{\pm}0.44$, $1.53{\pm}0.38$ for bones in underweight, normal weight, overweight, obese and severely obese groups, respectively. For liver, values of $SUV_{max}$ were $1.64{\pm}0.16$, $2.06{\pm}0.34$, $2.19{\pm}0.21$, $2.52{\pm}0.21$ and $2.74{\pm}0.40$ in the same order. And for lung, values of $SUV_{max}$ were $0.69{\pm}0.33$, $0.54{\pm}0.17$, $0.62{\pm}0.23$, $0.83{\pm0.29}$, $1.03{\pm}0.30$. Conclusion: By comparing and analyzing the differences between $SUV_{bw}$ and $SUV_{bsa}$ in this study, it was found that the differences between $SUV_{bw}$ and $SUV_{bsa}$ increased as patient's BMI increased. Thus, there is room for error in the values of SUV depending on the methods of calculations, and appropriate methods must be applied according to the circumstances in clinical settings.

  • PDF

A Study of the Change of Breast Uptake in Menstrual Cycle on $^{18}F$-FDG PET/CT (월경 주기에 따른 $^{18}F$-FDG PET/CT에서의 유방 섭취 변화에 관한 고찰)

  • Park, Min-Soo;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • Purpose: $^{18}F$-FDG PET/CT has been known a useful modality to diagnose high-glucose-using cells such as cancer cells by glucose metabolism of FDG. Mainly, FDG takes on cancer and inflammatory cells; However, There have been FDG uptakes on normal tissues by individual physiological characteristics, occasionally. Especially, in fertile females, unusual FDG uptake of breast changes as the menstrual cycle, and disturb diagnosis. Therefore, the study aimed to evaluate the change of breast FDG uptake in menstrual cycle on $^{18}F$-FDG PET/CT. Materials and Methods: 160 females ($34{\pm}3.5$ years old) who do not undergo a gynecologic anamnesis and have regular menstrual cycle over the previous 6 months were examined, from March 2009 to February 2010. They were divided 4 groups (each 40 patients) as flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator 0.14. and history taking. Discovery Ste (GE Healthcare, Milwaukee, Mi, USA) was used as PET/CT. We analyzed SUVs on accumulated region on breast, and 3 nuclear medicine specialists did the Blind test. Results: SUVs on the Breast were flow phase ($1.64{\pm}0.25$), proliferative phase ($0.93{\pm}0.28$), ovulatory phase ($1.66{\pm}0.26$) and secretory phase ($1.77{\pm}0.28$). It showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In gross analysis, the accumulation of breast was divided into 3 grades as comparing with lung and liver. The breast's uptake was equal to lung (Grade I); between lung and liver (Grade II); equal to or greater than liver (Grade III). The results showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). Conclusion: In fertile females, FDG uptake of breast changed as menstrual cycle, and it available to diagnose breast disease. Therefore, we consider reducing false-negative finding of breast disease, by doing examination on appropriate period through history taking about individual menstrual cycle.

  • PDF

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF

Evaluation of Usefulness for Diagnosis of Lung Cancer on Integrated PET-MRI Using Decision Matrix (판정행렬을 기반한 일체형 PET-MRI의 폐암 진단 유용성 평가)

  • Kim, Jung-Soo;Yang, Hyun-Jin;Kim, Yoo-Mi;Kwon, Hyeong-Jin;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.635-643
    • /
    • 2021
  • The results of empirical researches on the diagnosis of lung cancer are insufficient, so it is limited to objectively judge the clinical possibility and utilization according to the accuracy of diagnosis. Thus, this study retrospectively analyzed the lung cancer diagnostic performance of PET-MRI (Positron Emission Tomography-Magnetic Resonance Imaging) by using the decision matrix. This study selected and experimented total 165 patients who received both hematological CEA (Carcinoembryonic Antigen) test and hybrid PET-MRI (18F-FDG, 5.18 MBq/kg / Body TIM coil. VIVE-Dixon). After setting up the result of CEA (positive:>4 ㎍/ℓ. negative:<2.5㎍/ℓ) as golden data, the lung cancer was found in the image of PET-MRI, and then the SUVmax (positive:>4, negative:<1.5) was measured, and then evaluated the correlation and significance of results of relative diagnostic performance of PET-MRI compared to CEA through the statistical verification (t-test, P>0.05). Through this, the PET-MRI was analyzed as 96.29% of sensitivity, 95.23% of specificity, 3.70% of false negative rate, 4.76% of false positive rate, and 95.75% of accuracy. The false negative rate was 1.06% lower than the false positive rate. The PET-MRI that significant accuracy of diagnosis through high sensitivity and specificity, and low false negative rate and false positive rate of lung cancer, could acquire the fusion image of specialized soft tissue by combining the radio-pharmaceuticals with various sequences, so its clinical value and usefulness are regarded as latently sufficient.