• Title/Summary/Keyword: Pet Hospital

Search Result 556, Processing Time 0.021 seconds

Evaluation of the usefulness of prone position for reducing the image distortion due to respiration in PET/CT (PET/CT 검사 시 호흡에 따른 영상 왜곡 감소를 위한 엎드린 자세의 유용성 평가)

  • Lee, Han Wool;Kim, Jung Yul;Choi, Yong Hoon;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose The motion due to respiration of patients undergoing PET/CT is a cause of artifacts in image and registration error between PET and CT images. The degree of displacement and distortion for tumor, which affects the measurement of Standard Uptake Value (SUV) and lesion volume, is especially higher for tumors that is small or located at the base of lungs. The purpose of this study was to evaluate the usefulness of prone position in the correction of image distortion due to respiration of patients in PET/CT. Materials and Methods The imaging equipment used in this study was PET/CT Discovery 600 (GE Healthcare, MI, USA). 20 patients whose lesions were identified in the middle and lower lungs from May to August 2018 were enrolled in this study. After acquiring whole body image in the supine position, additional images of the lesion area were obtained in the prone position with the same conditions. SUVmax, SUVmean, and volume of the lesion were measured for each image, and the displacement of the lesion on PET and CT images were measured, compared, and analyzed. Results The SUVmax, SUVmean, and volume, and displacement of the lesion were $4.72{\pm}2.04$, $3.10{\pm}1.38$, $4.68{\pm}3.20$, and $4.64{\pm}1.88$, respectively for image acquired in the supine position and $5.89{\pm}2.42$, $3.97{\pm}1.65$, $2.13{\pm}1.09$, and $2.24{\pm}0.84$, respectively for image acquired in the prone position, indicating that, for all the lesions imaged, SUVmax and SUVmean were higher and volume and displacement were smaller in the images acquired in prone position compared to those acquired in supine one(p<0.05). Conclusion These results showed that the prone position PET/CT imaging improves the quality of the image by increasing the SUV of the lesion and reducing the respiratory artifacts caused by registration error between PET and CT images. It is considered that the PET/CT imaging in the prone position is helpful in the diagnosis of the disease as an economical and efficient methods that correct registration error for the lesions in basal lung and reduce artifacts.

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

The Study of Difference on Each System for Reliance Security in SUV of PET/CT Images : Initial Study (PET/CT 영상에서의 표준섭취계수(SUV)의 신뢰성 확보를 위한 시스템별 차이에 관한 연구 : 초기 연구)

  • Park, Hoon-Hee;Park, Min-Soo;Kim, Jung-Yul;Lee, Seung-Jae;Sheen, Hee-Soon;Lim, Han-Sang;Kim, Sei-Young;Jang, Hye-Won;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.5-6
    • /
    • 2008
  • In this study, using an experiment, in certified an error between each system of SUV (standardized uptake value) that is one of the main analyses to diagnose a tumor in PET/CT, so, it would assure reliability and help to diagnose any lesions accurately. That is, a detailed analysis progressed. as all images reconstructed every setting time, then, clinical reliability between each system was expressed numerically at MBq/mL and SUV. Therefore, this study is considered that flexibility of follow-up using diverse system was insured, and it helps to offer accurate and beneficial information for diagnosis of various fields.

  • PDF

Clinical Application of $^{18}F-FDG$ PET in Bile Duct Cancer (담도암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yun, Mi-Jin;Kim, Tae-Sung;Hwang, Hee-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.66-70
    • /
    • 2008
  • Reports about FDG PET in biliary tumor are limited and there are almost no reports regarding its efficacy. Biliary tumor is divided to intrahepatic and extrahepatic bile duct cancer, and intrahepatic bile duct cancer can be further divided to peripheral type which occurs at lobular duct and hilar type which occurs at hepatic hilum. Surgical resection is the only curative method for bile duct tumor, and accurate staging plays an important role in deciding treatment modality. Among intrahepatic bile duct tumors, peripheral type and hilar type have the same histological characteristics, but different clinical manifestations and tumor growth pattern. On PET image, FDG uptake is also different between peripheral type and hilar type. Most of the former shows high FDG uptake at primary and metastasis site so it is very useful for determining stage and changing treatment plans. However, the later is diversified among low uptake and very high uptake. The FDG uptake pattern of hilar type is similar to that of extrahepatic bile duct cancer, and mucinous component is an important factor, which affects FOG uptake. When tumor cells are scattered in desmoplatsic stroma, then FDG uptake is low as well. In contrast, when FDG uptake is high, it is likely to be tubular type which has high tumor density. Tumor growth pattern also affects FDG uptake. Nodular type mostly takes higher FDG compared to infiltrative type. There are many cases where benign inflammatory diseases take high FDG that PET alone can not distinguish malignant lesion from benign lesion. In conclusion, studies about PET using FDG are still limited. Thus, it is hard to make accurate conclusion about the roles of PET or PET/CT in biliary cancers, but peripheral type intrahepatic bile duct cancers and mass forming hilar and extrahepatic bile duct cancers appear to be good indications performing FDG PET or PET/CT.

A Case of Metastatic Tonsillar Lesion Showing Increased FDG Uptake in the Patient with Advanced Hepatocellular Carcinoma (진행성 간암 환자에서 편도 전이에 FDG 섭취증가를 보인 예)

  • Park, Jung-Mi;Kim, Hee-Kyung;Kim, Sang-Gyune;Kim, Young-Seok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.70-73
    • /
    • 2008
  • A 65 year-old man with hepatocellulcar carcinoma (HCC) admitted to treat left lower leg swelling and pus discharge suspecting osteomyelitis. MRI of his lower leg revealed the bone metastasis. Whole body FDG PET/CT additionally detected left shoulder and right ilium metastasis. Hematemesis suddenly developed in this patient after 3 weeks. Metastasis of right tonsil was histologically proven. When we reviewed his FDG PET/CT, there was asymmetric mild hypermetabolism in the right tonsil. When focal hypermetabolism is shown in the organ physiologically taking glucose up such as tonsil, we should cautiously assess whole body PET/CT in the examination of distant metastasis. We present a patient with multiple distant metastasis including tonsil from HCC showing increased FDG uptake with the literature review.

Patterns of FDG Uptake in Stomach on F-18 FDG Positron Emission Tomography: Correlation with Endoscopic Findings (F-18 FDG Positron Emission Tomography에서 보이는 위(stomach) 섭취 양상의 임상적 의의: 위 내시경 소견과 비교 평가)

  • Chae, Min-Jeong;Cheon, Gi-Jeong;Lee, Sang-Woo;Byun, Byung-Hyun;Kim, Sung-Eun;Kim, Yu-Chul;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.456-463
    • /
    • 2005
  • Purpose: we often find variable degrees of FDG uptake and patterns in stomach, which can make difficult to distinguish physiologic uptake from pathologic uptake on FDG PET. The purpose of this study was to find out the significant findings of stomach on FDG PET. Materials and Methods: Thirty-eight patients who underwent both FDG PET and endoscopy within one week from Jun. 2003, to Aug. 2004 were included in this study. We reviewed 38 patients (18 for medical check up, 15 for work up of other malignancies, and 5 for the evaluation of stomach lesion). Their mean age was 56 years old (range:$32{\sim}79$), men and women were 28 and 10, respectively. Two nuclear physicians evaluated five parameters on FDG PET findings of stomach with a consensus: 1) visual grades 2) maximum SUV (max.SUV) 3) focal 4) diffuse and S) asymmetric patterns. We correlated the lesions of FDG PET findings of stomach with those of endoscopy. We considered more than equivocal findings on FDG PET as positive. Results: The six of 38 patients were proven as malignant lesions by endoscopic biopsy and others were inflammatory lesions (ulcer in 3, chronic atrophic gastritis in 12, uncommon forms of gastritis in 5), non-inflammatory lesions (n=3), and normal stomach (n=9). By the visual analysis, malignant lesions had higher FDG uptake than the others. The max.SUV of malignant lesions was $7.95{\pm}4.83$ which was significantly higher than the other benign lesions ($2.9{\pm}0.69$ in ulcer, $3.08{\pm}1.2$ in chronic atrophic gastritis, $3.2{\pm}1.49$ in uncommon forms of gastritis (p=0.044)). In the appearance of stomach on FDG PET, malignant lesions were shown focal (5 of 6) and benign inflammatory lesions were shown diffuse (9 of 20) and asymmetric (14 of 20). Benign lesions and normal stomach were shown variable degrees of uptake and patterns. Some cases of benign inflammatory lesions such as ulcer and gastritis were shown focal and mimicked cancerous lesion (4 of 15). Conclusion: Gastric malignant lesions had higher FDG uptake and focal pattern. However, benign inflammatory lesions had moderate degrees of uptake and diffuse and asymmetric patterns rather than focal. It is difficult to differentiate between benign lesions including normal.

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Comparison of Blood Glucose Level in Pancreatic Cancer on $^{18}F$-FDG PET (췌장암 환자의 양전자방출단층촬영(PET) 검사 시 혈당치와 영상에 관한 분석)

  • Oh, Shin-Hyun;Lee, Seung-Jae;Park, Hoon-Hee;Park, Yong-Sung;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.65-69
    • /
    • 2011
  • Purpose: Normal pancreas has low uptake rate in $^{18}F$-FDG PET scan. However, it is possible to diagnose malignancy of pancreatic cancer which has high uptake rate. Many studies approve a high prevalence of diabetes in pancreatic cancer and if the blood glucose level (BGL) is over the normal range, FDG uptake will be decreased and there will be inconvenience for patients from the delay time to reduce the high BGL or could cause difficulty to arrange the schedule. Therefore, we studied the relation of BGL and image quality in pancreatic cancer on PET. Materials and Methods: A hundred patients had PET scan. The prevalence of pancreatic cancer and diabetes were evaluated using SPSS ver. 17. The fasting BGL of patients were examined and sorted as diabetes mellitus (DM) group and Non-DM group. For the evaluation, patients were divided into 3 groups (Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L). The ROI was drown on Liver and Lung for the PET imaging analysis. Results: Fifty three male and forty seven female were in the patients. The average age was $60.1{\pm}13.5$. There were 36 patients (male: 22, female: 14, 36%) who had pancreatic cancer with DM. There were 15 patients who showed over 7.0 mmol/L in their fasting BGL and 85 patients who showed under 7.0 mmol/L in their fasting BGL. Among the Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L, there was not a statistical significance (p>0.05). Conclusion: The prevalence of pancreatic cancer was comparatively high in this study. If the fasting BGL was slightly over the normal BGL, we believe it will not give a severe disturbance when the patients have PET scan. Furthermore, the examination schedule doesn't need to change and the inconvenience from the delay of patients preparation will be reduced.

  • PDF

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

Imaging Anatomy of Waldeyer's Ring and PET/CT and MRI Findings of Oropharyngeal Non-Hodgkin's Lymphoma

  • Zhang, Chun-Xing;Liang, Long;Zhang, Bin;Chen, Wen-Bo;Liu, Hong-Jun;Liu, Chun-Ling;Zhou, Zheng-Gen;Liang, Chang-Hong;Zhang, Shui-Xing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3333-3338
    • /
    • 2015
  • Background: This study was conducted to analyze positron emission tomography (PET) / computed tomography (CT) and magnetic resonance imaging (MRI) performance with oropharyngeal non-Hodgkin's lymphoma (ONHL).Materials and Methods: The complete image data of 30 ONHL cases were analyzed, all patients were performed PET / CT and MRI examination before the treatment, with the time interval of these two inspections not exceeding 14 days. The distribution, morphology, MRI signal characteristics, enhancement feature, standardized uptake value (SUV) max value and lymph node metastasis way of the lesions were analyzed. Results: Among the 30 cases, 23 cases were derived from the B-cell (76.7%), 5 cases were derived from the peripheral T cells (16.7%) and 2 cases were derived from the NK/T cells (6.7%). 19 cases exhibited the palatine tonsil involvement (63.3%). As for the lesion appearance, 10 cases appeared as mass, 8 cases were the diffused type and 12 cases were the mixed type. 25 cases exhibited the SUVmax value of PET / CT primary lesions as 11 or more (83.3%). MRI showed that all patients exhibited various degrees of parapharyngeal side-compressed narrowing, but MRI still exhibited the high-signal fat, and the oropharyngeal mucosa was intact. 25 cases were associated with the neck lymph node metastasis, among who 22 cases had no necrosis in the metastatic lymph nodes, while the rest 3 cases exhibited the central necrosis in the metastatic lymph nodes. Conclusions: PET / CT and MRI have important value in diagnosing and determining the lesion extent of ONHL.