• Title/Summary/Keyword: Pet Band

Search Result 26, Processing Time 0.023 seconds

Electroencephalography for Early Detection of Alzheimer's Disease in Subjective Cognitive Decline

  • YongSoo Shim;Dong Won Yang;SeongHee Ho;Yun Jeong Hong;Jee Hyang Jeong;Kee Hyung Park;SangYun Kim;Min Jeong Wang;Seong Hye Choi;Seung Wan Kang
    • Dementia and Neurocognitive Disorders
    • /
    • v.21 no.4
    • /
    • pp.126-137
    • /
    • 2022
  • Background and Purpose: Early detection of subjective cognitive decline (SCD) due to Alzheimer's disease (AD) is important for clinical research and effective prevention and management. This study examined if quantitative electroencephalography (qEEG) could be used for early detection of AD in SCD. Methods: Participants with SCD from 6 dementia clinics in Korea were enrolled. 18F-florbetaben brain amyloid positron emission tomography (PET) was conducted for all the participants. qEEG was performed to measure power spectrum and source cortical activity. Results: The present study included 95 participants aged over 65 years, including 26 amyloid PET (+) and 69 amyloid PET (-). In participants with amyloid PET (+), relative power at delta band was higher in frontal (p=0.025), parietal (p=0.005), and occipital (p=0.022) areas even after adjusting for age, sex, and education. Source activities of alpha 1 band were significantly decreased in the bilateral fusiform and inferior temporal areas, whereas those of delta band were increased in the bilateral cuneus, pericalcarine, lingual, lateral occipital, precuneus, posterior cingulate, and isthmus areas. There were increased connections between bilateral precuneus areas but decreased connections between left rostral middle frontal area and bilateral frontal poles at delta band in participants with amyloid PET (+) showed. At alpha 1 band, there were decreased connections between bilateral entorhinal areas after adjusting for covariates. Conclusions: SCD participants with amyloid PET (+) showed increased delta and decreased alpha 1 activity. qEEG is a potential means for predicting amyloid pathology in SCD. Further longitudinal studies are needed to confirm these findings.

Customized Pet Care and Training System Using Nose-Print Recognition, Pet Robot, and Pet Band (비문 인식, 펫 로봇 및 펫 밴드를 사용한 개체 맞춤형 반려동물 케어 및 훈련 시스템)

  • Cho, Ji-Yeon;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.909-912
    • /
    • 2020
  • This paper introduces a customized pet care and training system based on information technology. A specific animal is recognized by nose-print recognition. Pet robot induces the animal to move to trainer device. Trainer device trains the animal by snack, play, and clicker, and it can be easily extended for specific training using add-on devices. Pet band performs vital sign monitoring, prevention of home escape, and measurement of exercise amount. By changing configuration, this system can perform various training programs such as mitigation of separation anxiety, induction to defecation place, and prohibition of tresspassing specific place. It also provides customized training by analyzing individual behavior of animal. It can exercise and play the animal when owner is out, and it can immediately notice to the owner when the animal has health trouble.

Optical Properties of White Light Sources Using Red, Green, Blue Emitting Phosphors and Violet Light Emitting Diodes (적색, 녹색, 청색 발광 형광체와 보라색 발광 다이오드를 이용한 백색 광원의 광 특성)

  • Kweon, Seok-Soon;Park, Jong-Yun;Huh, Young-Duk
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.145-150
    • /
    • 2006
  • Various colors of light emitting diodes(LED) and four-band white light sources are obtained using a violet LED and various phosphor films. $BaMg_2Al_{16}O_{27}:Eu\;(blue),\;SrGa_2S_4:Eu\;(green),\;and\;Eu(TTA)_3(PTA)$ (red) phosphors are dispersed in poly-vinyl-alcohol aqueous solutions, and phosphor films are prepared by coating the suspensions to PET film. The narrow band emission of $Eu(TTA)_3(PTA)$ phosphor has excellent red luminescent property for four-band white light excited by the violet LED.

Structural Properties of chemically deposited CdS Films on plasma treated PET (고밀도 산소 플라즈마 처리된 폴리머 기판에 성장시킨 CdS 박막의 특성 분석)

  • Song, Woo-Chang;Park, Seung-Beom;Lim, Dong-Gun;Lee, Jae-Hyeong;Park, Jong-Kuk;Park, Ha-Yong;Kim, Jeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.228-228
    • /
    • 2008
  • CdS is II-VI semiconductor with a wide band gap of approximately 2.42 eV. CdS is the most popularly employed heterojunction partner to p-CdTe due to its similar chemical properties. In this work, to improvement of the surface properties of the CdS films, PET substrate is treated by high density $O_2$ plasma. CdS films are prepared by chemical bath deposition(CBD) method. In case of the PET substrate with plasma treatment for 2min, the crystalline orientation of CdS films exhibits a strong hexagonal(002). Grain size was increased from 300nm without $O_2$ plasma treatment to 380nm with an $O_2$ plasma treatment.

  • PDF

The Imaging Features of Desmoid Tumors: the Usefulness of Diffusion Weighted Imaging to Differentiate between Desmoid and Malignant Soft Tissue Tumors

  • Lee, Seung Baek;Oh, Soon Nam;Choi, Moon Hyung;Rha, Sung Eun;Jung, Seung Eun;Byun, Jae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.162-170
    • /
    • 2017
  • Purpose: To evaluate the imaging findings of desmoid tumors using various imaging modalities and to evaluate whether diffusion-weighted imaging (DWI) can help differentiate between desmoid and malignant tumors. Materials and Methods: The study included 27 patients with pathologically confirmed desmoid tumors. Two radiologists reviewed 23 computed tomography (CT), 12 magnetic resonance imaging (MRI) and 8 positron emission tomography-computed tomography (PET-CT) scans of desmoid tumors and recorded data regarding the shape, multiplicity, size, location, degree of enhancement, and presence or absence of calcification or hemorrhage. The signal intensity of masses on T1- and T2-weighted imaging and the presence or absence of whirling or band-like low signal intensity on T2-weighted imaging were recorded. The apparent diffusion coefficient (ADC) values of the desmoid tumors in nine patients with DWIs were compared with the ADC values of 32 malignant tumors. The maximum standardized uptake value ($SUV_{max}$) on PET-CT images was measured in 8 patients who underwent a PET-CT. Results: The mean size of the 27 tumors was 6.77 cm (range, 2.5-26 cm) and four tumors exhibited multiplicity. The desmoid tumors were classified by shape as either mass forming (n = 18), infiltrative (n = 4), or combined (n = 5). The location of the tumors was either intra-abdominal (n = 15), within the abdominal wall (n = 8) or extra-abdominal (n = 4). Among the 27 tumors, 21 showed moderate to marked enhancement and 22 showed homogeneous enhancement. Two tumors showed calcifications and one displayed hemorrhage. Eleven of the 12 MR T2-weighted images showed whirling or band-like low signal intensity areas in the mass. The mean ADC value of the desmoid tumors ($1493{\times}10^{-6}mm^2/s$) was significantly higher than the mean of the malignant soft tissue tumors ($873{\times}10^{-6}mm^2/s$, P < 0.001). On the PET-CT images, all tumors exhibited an intermediate $SUV_{max}$ (mean, 3.7; range, 2.3-4.5). Conclusion: Desmoids tumors showed homogenous, moderate to marked enhancement on CT and MRI scans and a characteristic whirling or band-like pattern on T2-weighted images. DWI can be useful for the differentiation of desmoid tumors from malignant soft tissue tumors.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Analysis of the Fracture Behavior of Plate-type Piezoelectric Composite Actuators by Acoustic Emission Monitoring (음향방출법을 이용한 평판형 압전 복합재료 작동기의 파괴거동 해석)

  • Woo, Sung-Choong;Goo, Nam-Seo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.220-230
    • /
    • 2006
  • Fracture behavior of a monolithic PZT and a plate-type piezoelectric composite actuator (PCA) has been investigated under a bending load at three points by an acoustic emission (AE) monitoring. AE signal from a monolithic PZT at the maximum bending load shows the characteristics of high amplitude and long duration with a low frequency band of $100{\sim}230kHz$ which is confirmed by fast Fourier transform (FFT). For a PCA, it is concluded that AE signals with high amplitude over 80dB and low dominant frequency band of $170{\sim}223kHz$ emitted in the stage I are due to the brittle fracture in the PZT layer and the delamination between the PZT layer and the adjacent fiber composite layer. Based on the above analysis of AE behavior and damage observations with an optical microscopy and a scanning electron microscopy, AE characteristics related to fracture behavior of asymmetrically laminated PCA have been elucidated.

A Study on Structural and Electrical Properties of ZnO Thick Films on the Glass Substrate and PET Film (Glass Substrate와 PET Film위에 Screen Printing된 ZnO Thick Film의 구조적 전기적 특성)

  • Lee, Ku-Tak;Jeon, Min-Cheol;Chae, Moon-Soon;Lee, Kyung-Ju;Moon, Byung-Moo;Koh, Jung-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.355-358
    • /
    • 2011
  • As a II-IV compound semiconductor, ZnO has a wide band gap of 3.37 eV with transparent properties. Due to this transparent properties, ZnO materials can be also employed as the transparent conducting electrode materials. Recently, rapid progress has been made in the field of DSSC (dye sensitized solar cell)area. Therefore, strong demands have been required for the transparent electrodes with low temperature processing and cheap cost. In this paper, we will prepare ZnO thick films on the PET substrates for the electrode applications. We will investigate the structural and microstructure properties through the XRD, and SEM analysis, respectively. Also, we will study the electrical of specimens to apply the conducting electrode.

Electrical Properties of ITO/Ag/ITO Conducting Transparent Thin Films (ITO/Ag/ITO 투명전도막의 전기적 특성)

  • Chae, Hong-Chol;Baeg, Chang-Hyun;Hong, Joo-Wha
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.2
    • /
    • pp.192-196
    • /
    • 2011
  • The multi-layered thin film with an ITO/Ag/ITO structure was produced on PET by using magnetron reactive sputtering method. First, 30 nm of ITO thin film was coated on PET by using normal temperature process. Then 20-52 nm of the Ag thin film was coated. Lastly, 30 nm of ITO thin film was coated on Ag layer. The sample of the 20 nm Ag thin film showed more than 70% transmission and a $2.7{\Omega}/{\Box}$ sheet resistance. When compared to the existing single-layered transparent conducting thin film, multi-layered film was found to be superior with about $5{\Omega}/{\Box}$ less sheet resistance. However, since the Ag layer became thinner, the band gap energy needs to be increased to more than 3.5 eV.

Development of UHF Band Tag Antenna using Radio Frequency Identification Multipurpose Complex Card (RFID 다기능 복합 카드용 UHF 대역 소형 태그 안테나 개발)

  • Byun, Jong-Hun;Sung, Bong-Geun;Choi, Eun-Jung;Ju, Dae-Geun;Yoo, Dae-Won;Cho, Byung-Lok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1452-1458
    • /
    • 2009
  • In this paper, Our proposed Multipurpose Complex Card UHF band RFID small-size Tag antenna. Multi purpose Complex Card UHF band RFID small-size Tag antenna that is to minimize the low efficiency of RFID Tag Read Range that generates space limitation and a conductor surrounded by inducing fingerpring system with dual(HF, UHF) Card is presented. Our proposed UHF band RFID small-size Tag antenna is for the Multipurpose Complex Card that is mounted on the fingerpring system as well as the HF Tag. It also enables to minimize and facilitates Tag chip matching by adjusting Tapered, Meander line and Loop structure. Given the card substance properties and periphery circuit, the proposed small-size Tag antenna, in this report, is designed with PET film with size of $50{\times}15mm^2$. The RFID small-size Tag method for measurements is used by EPCglobal Static Test instrument in Anechoic Chamber, which is tested with dual Card, within the car and in wallet. It is found that Read Range is 3.8m from the EPCglobal Static Test, Maximum Read Range within the car from the field test results in 7.6m. Proposed Tag antenna is will be used in the parking control security system.