• Title/Summary/Keyword: Permissible limits

Search Result 91, Processing Time 0.03 seconds

Assessment of Fire Risk Rating for Wood Species in Fire Event (화재 발생 시 목재 수종의 화재위험성 등급 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.423-430
    • /
    • 2021
  • In order to evaluate the fire risk and fire risk rating of wood for construction materials, this study focused on fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) according to Chung's equations-III and -IV. Western red cedar, needle fir, ash, and maple were used as the specimens. The fire characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment on the specimen. The FPI-III measured after the combustion reaction was 0.86 to 12.77 based on polymethylmethacrylate (PMMA). The FGI-III was found to be 0.63 to 5.26 based on PMMA. The fire rating according to the FRI-IV, which is the fire rating index, was 0.05 to 6.12, and the western red cedar was 122.4 times higher than that of the maple. The fire risk rating according to the FRI-IV increased in the order of maple, ash, needle fir, PMMA and western red cedar. The CO peak concentration of all specimens was measured as 103 to 162 ppm, and it was 2.1 to 3.2 times higher than 50 ppm, the permissible exposure limits of the US occupational safety and health administration. Materials such as western red cedar, which have a low bulk density and contain a large amount of volatile organic substances, have a low FPI-III and a high FGI-III, so they have a high fire risk rating.

Monitoring and Risk Assessment of Pesticide Residues in Commercial Environment Friendly Fruits and Fruiting Vegetables (유통 친환경 과실류와 과채류 중 농약잔류 실태조사 및 안전성 평가)

  • Lee, Jae Yun;Noh, Hyun Ho;Park, So Hyun;Lee, Kwang Hun;Park, Hyo Kyoung;Hong, Su Myeong;Kim, Doo Ho;Kyung, Kee Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.308-314
    • /
    • 2012
  • In order to monitor the residual pesticides in environment friendly agricultural commodities, fruits and fruiting vegetables. Twenty-five agricultural commodities were collected twice in May and August 2011 from nine environment friendly agricultural commodities-selling supermarkets and retail stores located in eight major cities in Korea. The number of each agricultural commodity collected, 555 samples in total, was 152 organic agricultural products, 202 pesticide-free agricultural products and 201 low-pesticide agricultural products. Pesticide residues in samples were analyzed by multiresidue method for 245 pesticides using a GC-ECD/NPD and an HPLC-DAD/FLD and the peaks suspected as pesticides were identified with a GC/MSD. As a result of pesticide residue analysis, three pesticides, bifenthrin, EPN and chlorpyrifos, were detected from four samples including apple, representing a detection rate of 0.72%. The residue levels of the four pesticide-detected samples were less than their maximum residue limits (MRLs) but one pesticide EPN detected from pear exceeded its legible criterion of one twentieth MRL. Estimated daily intakes of the pesticides detected from fruits and fruiting vegetables were less than 0.76% of their maximum permissible intake.

A Legal Review on Physical Therapists' Roles and Doctors' Superintendency (물리치료사의 업무범위와 의사의 지도권에 관한 법적 검토 - 청주지방법원 2010. 2. 3. 선고 2009노1317 판결 -)

  • Kim, Han-Nah;Kim, Kye-Hyun
    • The Korean Society of Law and Medicine
    • /
    • v.11 no.2
    • /
    • pp.337-361
    • /
    • 2010
  • In the case of Korea, both of modern medicine and oriental medicine are admitted as medical practices in the system. In other words, healthcare system is dualized. However, medical practice that corresponds to oriental medicine in Korea is substitution of medical practice in cases of foreign countries. For use of medical devices, it is provided only for doctors and medical technician relevant to use. Particularly, although oriental medicine is recognized as orthodox medicine in terms of the features of Korean medical system, superintendency of oriental doctors is not identical with that of doctors for use of medical devices and superintendency toward medical technicians. Recently, Cheongju District Court decided that superintendency of oriental doctor upon physical therapist is not acknowledged. It can be said that the judgement is opposed to the original verdict which judged that oriental doctors' employment and guidance of oriental doctors upon physical therapist is permissible. Hence this study aimed to review on domestic medical law system, which is dualized, roles of medical professionals, intent of the medical license system, provisions related to medical technician law and relevant precedents. Regulations on practices other than licensed practices by medical professionals are made because medical practices may affect on danger toward life and body of human and public health also. Therefore, the nation regulates medical professionals having licenses to perform medical practices within the range of the licenses. It is clearly prescribed that medical technicians may perform medical practices under instructions of doctors or dentists pursuant to the medical technician law. In addition, the court also judges that it is out of the license of oriental doctors if they use CT devices and limits the use of modern medical devices by oriental doctors. That is to say that it limits oriental doctors' employment of medical technicians and pursuant of oriental doctors on medical technicians as well.

  • PDF

Controlling Painters' Exposure to Volatile Organic Solvents in the Automotive Sector of Southern Colombia

  • Castano, Belky P.;Ramirez, Vladimir;Cancelado, Julio A.
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.355-361
    • /
    • 2019
  • Background: Painters in the automotive sector are routinely exposed to volatile organic solvents, and the levels vary depending on the occupational health and safety controls enforced at the companies. This study investigates the levels of exposure to organic vapors and the existence of controls in the formal economy sector in southern Colombia. Methods: This is an exploratory study of an observational and descriptive character. An analysis of solvents is conducted via the personal sampling of painters and the analysis of samples using the National Institute for Occupational Safety and Health 1501 method. The amount of solvents analyzed varied according to the budget allocated by the companies. The person in charge of the occupational safety and health management system was interviewed to learn about the exposure controls implemented at the companies. Results: A medium exposure risk for toluene was found in one company. Another presented medium risk for carbon tetrachloride, xylene, ethylbenzene, and n-butanol. The others showed low risk of exposure and that the controls implemented were not sufficient or efficient. Conclusion: These results shed light on the working conditions of these tradespeople. The permissible limits established by Colombian regulations for the evaluated chemical contaminants were not exceeded. However, there were contaminants that exceeded the limits of action. The analysis of findings made it possible to propose improvements in occupational safety and health management systems to allow the optimization of working conditions for painters, prevent the occurrence of occupational diseases, and reduce costs to the country's health system.

Security Cost Analysis with Linear Ramp Model using Contingency Constrained Optimal Power Flow

  • Lyu, Jae-kun;Kim, Mun-Kyeom;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.353-359
    • /
    • 2009
  • This paper proposes a novel technique for calculating the security costs that properly includes ramping constraints in the operation of a deregulated power system. The ramping process is modeled by a piecewise linear function with certain assumptions. During this process, a ramping cost is incurred if the permissible limits are exceeded. The optimal production costs of the power producers are calculated with the ramping cost included, considering a time horizon with N-1 contingency cases using contingency constrained optimal power flow (CCOPF), which is solved by the primal-dual interior point method (PDIPM). A contingency analysis is also performed taking into account the severity index of transmission line outages and its sensitivity analysis. The results from an illustrative case study based on the IEEE 30-bus system are analyzed. One attractive feature of the proposed approach is that an optimal solution is more realistic than the conventional approach because it satisfies physical constraints, such as the ramping constraint.

Local Cooling of the Limbs in $37^{\circ}C$ Ambient Temperature (사지부의 냉각효율성에 관한 연구)

  • Hwang, Kyoung-Sook;Choi, Jeong-Wha;Lee, Kyung-Suk
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.1
    • /
    • pp.87-95
    • /
    • 2007
  • This study was to determine the effect of cooling parts of the limbs without harm to health. The results provide basic data for the development of clothing which could increase work efficiency and reduce body strain in hot environments. Five male adults took part in the study, conducted in a climate chamber with an ambient temperature of $37^{\circ}C$ and a relative humidity of 50%. The limbs were divided into six areas to be cooled: upper arm, forearm, thigh, calf, hand, and foot. According to preceding studies, permissible cooling safety limits of skin temperature for each part of the body for one-hour were $20^{\circ}C$ on the upper arm, forearm, thigh, and calf, and $23^{\circ}C$ on the hand and foot. For this reason, cooling the skin of each region was carried out at the above mentioned temperatures. In conclusion, cooling the hand and foot reduced perspiration, rectal temperature and heart rate. Therefore, the heat stress of workers exposed to hot environments would be reduced by decreased subjective sensations of heat and increased comfort. The effectiveness of cooling was better on the arm than on the leg.

  • PDF

Pharmacognostical Evaluation of Seed of Butea monosperma Kuntze

  • Srivastava, Manjoosha;Srivastava, Sharad Kumar;Khatoon, Sayyada;Rawat, A.K.S.;Mehrotra, Shanta
    • Natural Product Sciences
    • /
    • v.8 no.3
    • /
    • pp.83-89
    • /
    • 2002
  • Butea monosperma Kuntze, commonly known as 'Palash', is employed in various indigenous systems of medicine against several diseases and almost every part of the plant has diversified medicinal properties. The seeds are used as anthelmintic, aperient, digesti and to treat piles, skin diseases and abdominal troubles. They also have the property of reducing 'Kapha' and 'Vata' (in Ayurveda). In the present paper a detailed pharmacognostical evaluation of seeds has been undertaken. The study includes macro- and micro-scopical details, fluorescence powder study and HPTLC fingerprinting. The seed is characterized by finely ridged seed coat and palisade-like malpighian cells, discontinuous transparent linea lucida in upper half of malpighian layer and simple & oblong hilum. The study also concludes that the seed samples procured from different places have similar morphological and physico-chemical characteristics. These observations are also supported by similar TLC profiles. The estimation of heavy metals (to detect permissible toxic limits), and fatty acid composition have been carried out. An attempt has also been made to see the ecological and edaphic variations, if any.

Guidelines for Microbiological Standards of Food in Foreign Countries (제외국의 식품안전관련 미생물 정량기준 가이드라인)

  • Lee, Mi-Seon;Woo, Gun-Jo;Park, Jong-Seok;Lee, Dong-Ha;Oh, Sang-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.3
    • /
    • pp.140-150
    • /
    • 2004
  • It has been recognized that international food standards should be considered for a long time. The Codex Alimentarius programme initiated in the early 1960s has received valuable background documentation from the ICMSF (International Commission on Microbiological Specification for Foods) and also from ISO(the International Organization for Standardization). There has been a considerable move towards international harmonization of standards and methods of analysis. Many foreign countries recommend the guidelines for food microbiological standards quantitatively. To complement microbiological limits and tolerance levels for permissible number of defective samples, allowances should be made for sampling and other variations in laboratory methods. It may be necessary for guidelines of domestic food microbiological standards to be established so that the domestic food standards can be harmonized with foreign food standards. Food safety related microbiological guidelines of ICMSF, EU (European Union), UK (United Kingdom), China (Hong Kong) and Japan were reviewed and shown in examples.

The Propriety of Design Outlet Conduit of Dam by Hydraulic Model Experiments (수리모형실험을 활용한 댐 방류관 설계의 적정성 검토)

  • Choi, Byong-Kyu;Kang, Tae-Ho;Jung, Yo-Han
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.811-821
    • /
    • 2003
  • In this study is if the design of outlet conduit was appropriate or not by analyzing flow characteristic of outlet conduit with performing hydraulic model experiments. As the results of hydraulic model experiments, the capacity of outlet conduit of elementary design was under estimated, and the designed values of the capacity of outlet conduit of preliminary design based on the values of elementary design was nearly equal to the values of experiments, so the propriety of design was identified. In addition, as the results of examinations of negative pressure of outlet conduit, and propriety of longitudinal sections, the resulting values were within the maximum permissible limits, so it was proved that the design was appropriate. In the base of such processes, the propriety of scale and location of outlet conduit of preliminary design was examined.

Development of Large Tuned Mass Damper with Stroke Control System for Seismic Upgrading of Existing High-Rise Building

  • Hori, Yusuke;Kurino, Haruhiko;Kurokawa, Yasushi
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.3
    • /
    • pp.167-176
    • /
    • 2016
  • This paper describes a large tuned mass damper (TMD) developed as an effective seismic control device for an existing highrise building. To realize this system, two challenges needed to be overcome. One was how to support a huge mass that has to move in any direction, and the second was how to control mass displacement that reaches up to two meters. A simple pendulum mechanism with strong wires was adopted to solve the first problem. As a solution to the important latter problem, we developed a high-function oil damper with a unique hydraulic circuit. When the mass velocity reaches a certain value, which was predetermined by considering the permissible displacement, the damper automatically and drastically increases its damping coefficient and limits the mass velocity. This velocity limit function can effectively and stably control the mass displacement without any external power. This paper first examines the requirements of the TMD using a simple model and clarifies the constitution of the actual TMD system. Then the seismic upgrading project of an existing high-rise building is outlined, and the developed TMD system and the results of performance tests are described. Finally, control effects for design earthquakes are demonstrated through response analyses and construction progress is introduced.