• Title/Summary/Keyword: Permissible limits

Search Result 91, Processing Time 0.03 seconds

Biological Exposure Indices of Organic Solvents for Korean Workers (유기용제의 생물학적 폭로기준 설정에 관한 연구)

  • Jang, Jae Yeon;Chun, Hyang Sook;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.192-199
    • /
    • 1991
  • Biological exposure indices (BEI) of toluene, perchloroethylene (PCE) and methyl ethyl ketone (MEK) for Korean workers were studied respectively. Environmental exposures in workplace to organic solvent were measured by personal sampling. Blood toluene, blood perchloroethylene, urinary trichloroacetic acid and urinary MEK were determined by headspace gas chromatography. Urinary hippuric acid were determined by HPLC and corrected by creatinine. BEIs for Korean workers were calculated as the levels of determinants which are correspond to permissible exposure limits in Korea. Blood toluene level of 2.2mg/l and urinary hippuric acid level of 1.7g/g creatinine are correspond to an exposure of 100 ppm toluene. Blood PCE concentration of 1.6mg/l and urinary trichloroacetic acid concentration of 2.9mg/l are correspond to an exposure of 50ppm PCE. Urinary MEK concentration of 1.0mg/l is correspond to an exposure of 200ppm of MEK. BEIs for Korean workers determined in this study are very different to ACGIH's BEI as urinary determinants are much lower and blood determinants are much higher than ACGIH's BEI.

  • PDF

A Study on Worker Exposure to Organic Solvents in Korea (우리나라 산업장 근로자의 유기용제 폭로에 관한 연구)

  • Paik, Nam Won;Lee, Young Hwan;Yoon, Chung Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.88-94
    • /
    • 1998
  • Korea has been rapidly industrialized during the past 35 years. During this period, Korea has emphasized only production and workers health has been ignored. Workers are most frequently exposed to organic vapors, such as thinners. This study was performed to evaluate worker exposures to organic solvents by size and type of industry. Results are summarized below. Workers were exposed to mixtures of toluene, xylenes, trichloroethylene, n-hexane, acetone, methanol, n-butanol, n-butyl acetate, and MIBK. Considering additive effects of the compounds, exposure indices (EIs) were calculated. It was found that worker exposures to organic solvents were highest in small industries and lowest in large industries. During a day shift, the highest exposure was indicated 3 - 5 p.m. in the afternoon. Workers in small industries had potential exposures exceeding permissible exposure limits for organic solvents. Local exhuast systems were inappropriate and respiratory protective devices were not supplied to the workers in small industries. Neither program for safe use and storage of toxic materials nor program for respirators was found in any of the plants investigated. Based on the results of the study, workers of small scale industries should be considered first in industrial health.

  • PDF

Seismic analysis of frame-strap footing-nonlinear soil system to study column forces

  • Garg, Vivek;Hora, Manjeet S.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.5
    • /
    • pp.645-672
    • /
    • 2013
  • The differential settlements and rotations among footings cannot be avoided when the frame-footing-soil system is subjected to seismic/dynamic loading. Also, there may be a situation where column(s) of a building are located near adjoining property line causes eccentric loading on foundation system. The strap beams may be provided to control the rotation of the footings within permissible limits caused due to such eccentric loading. In the present work, the seismic interaction analysis of a three-bay three-storey, space frame-footing-strap beam-soil system is carried out to investigate the interaction behavior using finite element software (ANSYS). The RCC structure and their foundation are assumed to behave in linear manner while the supporting soil mass is treated as nonlinear elastic material. The seismic interaction analyses of space frame-isolated footing-soil and space frame-strap footing-soil systems are carried out to evaluate the forces in the columns. The results indicate that the bending moments of very high magnitude are induced at column bases resting on eccentric footing of frame-isolated footing-soil interaction system. However, use of strap beams controls these moments quite effectively. The soil-structure interaction effect causes significant redistribution of column forces compared to non-interaction analysis. The axial forces in the columns are distributed more uniformly when the interaction effects are considered in the analysis.

Review of Hazardous Agent Level in Wafer Fabrication Operation Focusing on Exposure to Chemicals and Radiation (반도체 산업의 웨이퍼 가공 공정 유해인자 고찰과 활용 - 화학물질과 방사선 노출을 중심으로 -)

  • Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Objectives: The aim of this study is to review the results of exposure to chemicals and to extremely low frequency(ELF) magnetic fields generated in wafer fabrication operations in the semiconductor industry. Methods: Exposure assessment studies of silicon wafer fab operations in the semiconductor industry were collected through an extensive literature review of articles reported until the end of 2015. The key words used in the literature search were "semiconductor industry", "wafer fab", "silicon wafer", and "clean room," both singly and in combination. Literature reporting on airborne chemicals and extremely low frequency(ELF) magnetic fields were collected and reviewed. Results and Conclusions: Major airborne hazardous agents assessed were several organic solvents and ethylene glycol ethers from Photolithography, arsenic from ion implantation and extremely low frequency magnetic fields from the overall fabrication processes. Most exposures to chemicals reported were found to be far below permissible exposure limits(PEL) (10% < PEL). Most of these results were from operators who handled processes in a well-controlled environment. In conclusion, we found a lack of results on exposure to hazardous agents, including chemicals and radiation, which are insufficient for use in the estimation of past exposure. The results we reviewed should be applied with great caution to associate chronic health effects.

A Design of Automated Contingency Management and Case Study for Monopropellant Propulsion System (단일추진시스템의 ACM 설계 및 사례연구)

  • Lee, Young-Jin;Lee, Kwon-Soon;Vachtsevanos, George
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.2
    • /
    • pp.1-11
    • /
    • 2008
  • Increasing demand for improved reliability and survivability of mission-critical systems is driving the development of health monitoring and Automated Contingency Management (ACM) systems. An ACM system is expected to adapt autonomously to fault conditions with the goal of still achieving mission objectives by allowing some degradation in system performance within permissible limits. ACM performance depends on supporting technologies like sensors and anomaly detection, diagnostic/prognostic and reasoning algorithms. This paper presents the development of a generic prototype test bench software framework for developing and validating ACM systems for advanced propulsion systems called the Propulsion ACM (PACM) Test Bench. The architecture has been implemented for a Monopropellant Propulsion System (MPS) to demonstrate the validity of the approach. A Simulink model of the MPS has been developed along with a fault injection module. It has been shown that the ACM system is capable of mitigating the failures by searching for an optimal strategy. Furthermore, the concepts of Validation and Verification (V&V) of such systems are introduced with relevant examples.

  • PDF

A Comparative Study for Odor Control Regulations (악취관리제도의 국가간 비교연구)

  • 양성봉;김석만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

Quantification of the Sub-lethal Toxicity of Metals and Endocrine-disrupting Chemicals to the Marine Green Microalga Tetraselmis suecica

  • Ebenezer, Vinitha;Ki, Jang-Seu
    • Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.187-194
    • /
    • 2013
  • Microalgae are sensitive indicators of environmental changes, and hence they are widely used in environmental risk assessments and for the development of discharge guidelines. Here we evaluated the toxicity of metals and endocrine-disrupting chemicals (EDCs) to the marine green microalga, Tetraselmis suecica. The toxicants investigated included the metals, Cu, Ni, and Pb; and the EDCs, bisphenol A (BPA), endosulfan (ES), and polychlorinated biphenyl (PCB). The endpoints were variations in cell counts and chlorophyll a levels. T. suecica displayed a varied pattern of sensitivity to the toxicants. Based on the 72-h median effective concentration ($EC_{50}$), ES (0.045 mg/L) was most toxic to T. suecica, followed by PCB (3.96 mg/L) and Pb (9.62 mg/L). Interestingly, T. suecica was relatively tolerant to Cu (43.03 mg/L). The 72-h $EC_{50}$ values of Ni and BPA were approximately 16 mg/L. Our data suggest that this species may be relatively tolerant to most of the chemicals within their permissible limits in the environment.

A Study on Size Optimization of the Big Bracket in the Cargo Hold of Crude Oil Tanker (유조선 화물창내 대형 브라켓 치수 최적화 연구)

  • Lee Jong Hwan;Shin Sang Hoon;Kim Doehyun;Hwon Jin Chil
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.63-68
    • /
    • 2005
  • Optimum design of the big brackets is performed through iterated 3-D FE analyses to meet the permissible limits of stress, which consumes an excessive amount of calculation time. Therefore, this study has been prepared to determine rapidly and accurately an optimum size and scantling of the big brackets at the initial design stage. The generalized slope deflection method (GSDM) based on the span point concept is applied to enhance the efficiency of iterated structural analyses. The accuracy and applicability of the present method is verified by comparing with a detail 3-D FE analysis of web frame structures. As an optimization technique, evolution strategies (ES) are applied using discrete design variables for practical design.

  • PDF

Effects of Local Cooling on Heat Strain in the Hot Environment -On the Trunk Region-

  • Hwang, Kyoung-Sook;Choi, Jeong-Wha;Lee, Kyung-Suk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.3
    • /
    • pp.211-216
    • /
    • 2007
  • This study was to determine the effect of cooling part of the trunk without harm for the health. The results provide basic data for the development of clothing which could increase work efficiency and reduce body strain in hot environment. Eight males took part in the study. The experiment was conducted in a climate-chamber controlled with $37{\pm}1^{\circ}C,\;50{\pm}5%R.H$. The trunk was divided into six areas to be cooled: head, neck, chest, abdomen, the upper back, the lower back. According to preceding studies, permissible safety cooling limits of skin temperature, of each part of the trunk for four hours cooling were $25^{\circ}C$ on the head, $20^{\circ}C$ on the neck, $27^{\circ}C$ on the chest, $25^{\circ}C$ on the abdomen, $20^{\circ}C$ on the upper back, $20^{\circ}C$ on the lower back. So cooling temperatures of each region set up temperatures above mentioned. In conclusion, the head, the neck and the upper back cooling could reduce sweating amount, rectal temperature and heart rates and reduce the heat stress of workers exposing in the hot environment by decreased subjective sensations of heat and comfort. Thus, it was concluded that effectiveness of cooling among the trunk was best on the head and the neck.

Enhancing seismic performance of ductile moment frames with delayed wire-rope bracing using middle steel plate

  • Ghalandari, Akram;Ghasemi, Mohammad Reza;Dizangian, Babak
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.139-147
    • /
    • 2018
  • Moment frames have considerable ductility against cyclic lateral loads and displacements; however, sometimes this feature causes the relative displacement to exceed the permissible limits. This issue can bring unfavorable hysteretic behavior on the frame due to the reduction in the stiffness and resistance against lateral loads. Most of common bracing systems usually control lateral displacements through increasing stiffness while result in decreasing the capacity for energy absorption. This has direct effect on hysteresis curves of moment frames. Therefore, a system that is capable of both having the capacity of energy absorption as well as controlling the displacements without a considerable increase in the stiffness is quite important. This paper investigates retrofitting of a single-storey steel moment frame using a delayed wire-rope bracing system equipped with the ductile middle steel plate. The steel plate is considered at the middle intersection of wire ropes, where it causes cables to be continuously in tension. This integrated system has the advantage of reducing considerable stiffness of the frame compared to cross bracing systems as a result of which it could also preserve the frame's energy absorption capacity. In this paper, FEM models of a delayed wire-rope bracing system equipped by steel plates with different geometries have been studied, validated, and compared with other researchers' laboratory test results.