• Title/Summary/Keyword: Permeability coefficient

Search Result 608, Processing Time 0.043 seconds

Properties of Polymer Permeability Concrete Using Recycled Aggregate (재생골재를 활용한 폴리머 투수콘크리트의 특성)

  • Kim, Young-Ik;Sung, Chan-Yong;Choi, Sang-Leung;Joung, Duck-Hyun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.415-418
    • /
    • 2003
  • This study is performed to examine properties of polymer permeability concrete using recycled coarse aggregate and blast furnace slag for application of structures needed permeability. Tests for compressive strength, flexural strength and pulse velocity with replacement ratio of recycled coarse aggregate are performed. As a result, compressive strength, flexural strength and coefficient of permeability of polymer permeability concrete containing recycled coarse aggregate are in the range of $180{\sim}200kgf/cm^2,\;58{\sim}64kgf/cm^2\;and\;4.6{\times}10^{-2}{\sim}6.9{\times}10^{-2}cm/s$, respectively. Compressive strength, flexural strength and pulse velocity of polymer concrete containing crushed stone only are $192kgf/cm^2,\;65kgf/cm^2\;and\;6.1{\times}10^{-2}cm/s$, respectively. Accordingly, recycled coarse aggregate is expected that can be utilizing as an aggregate of polymer permeability concrete.

  • PDF

Permeability Coefficient of Unsaturated Soil in Steep Slope Failure Area (붕괴가 발생한 급경사지의 현장 투수계수)

  • Choi, Eun-Kyeong;Kim, Sung-Wook;Park, Dug-Keun;Oh, Jeong-Rim
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.921-926
    • /
    • 2010
  • To examine saturation characteristics of an unsaturated soil in the steep slope area with collapse, it separated dry season from rainy season and measured water content and permeability, and measured permeability by using a tension infiltrometer in the site. In addition, it conducted electrical resistivity survey to look into thickness of ground and geological structure of underground. The collapsed slope increased depth of weathered zone compared to upper slope, and there electrical resistivity anomalous zone caused by the filtrated underground water was observed. The permeability of the collapsed area was observed high compared to upper and lower slopes of retarding basin without collapse, and the permeability measured by dividing the dry season and rainy season was measured high in case of dry season.

  • PDF

A Study on the Evaluation of Durability of Fiber Reinforced Concrete According to the Change of External Conditions (외부조건의 변화에 따른 섬유보강콘크리트의 내구성능 정가에 관한 연구)

  • Kim, Nam-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.97-104
    • /
    • 2008
  • This study was intended to evaluate the permeable performance through a change of reinforcing materials, curing condition, durability evaluation and permeability test, and to select the reinforcing material which could reduce the durability and water tightness from it, as the study for considering how the change of the outside's environment factors that the concrete structure actually contacted with impacted the concrete's durability especially the permeability by referring to such the background of the study. Accordingly, it was judged that evaluating the permeability by considering the severe environment condition where the concrete structure was placed in was more reasonable than measuring the existing permeability coefficient conducted in the sound state for the permeability evaluation of actually-used concrete structure. In this study, it also could be known that the specimen of hybrid fiber reinforced concrete which mixed the long and short steel fiber was the most effective for water tightness enhancement in severe environmental conditions.

Influence of the Gradation of Aggregates on Permeability of Polymer Concrete (폴리머콘크리트의 투수성에 미치는 골재 입도 분포의 영향)

  • 윤길봉;이병렬;전찬기;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.141-146
    • /
    • 2001
  • Permeable polymer concrete has a lot of internal voids, which has more excellent performance in permeability and durability than asphalt and cement concrete. Therefore, in this paper, influences of grading distribution of aggregates on the permeable polymer concrete are presented using polyester resin as binders. According to test results, it shows that compressive strength and unit weight increase with continuous grading distribution and increase of binder content, while void and permeability coefficient shows decline tendency

  • PDF

Evaluation of Overburden Pressure on Soil-Water Retention Characteristics of Unsaturated Weathered Soils (상재하중의 영향을 고려한 불포화 풍화토의 함수특성 평가)

  • Park, Jai-Young;Park, Seong-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.111-118
    • /
    • 2008
  • The purpose of this paper was to investigate the overburden effect on soil-water characteristic curve and unsaturated permeability of unsaturated weathered soils. For this, unsaturated suction and permeability tests under various overburden stress were conducted respectively. Then, the coefficient of unsaturated permeability and moisture capacity of weathered soils were estimated and compared. All these results are presented in the paper.

  • PDF

Engineering properties of permeable polymer concrete for pavement using powdered waste glass as filler (폐유리분말을 충전재로 사용한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Kim, Tae-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.145-151
    • /
    • 2011
  • This study was performed to evaluate the void ratio, compressive and flexural strength, and permeability coefficient used powdered waste glass, $CaCO_3$, recycled coarse aggregate and unsaturated polyester resin to find optimum mix design of permeable polymer concrete for pavement. The void ratio and permeability coefficient of permeable concrete for pavement was decreased with increasing the powdered waste glass, respectively. The compressive strength and flexural strength was increased with increasing the powdered waste glass, respectively. In addition, this study found out that required amount of binder was decreased with increasing the powdered waste glass. This fact is expected to have economical effects during the use of powdered waste glass in the manufacture of permeable polymer concrete for pavement. Therefore, powdered waste glass and recycled coarse aggregate can be used for permeable polymer pavement.

A Study on Watertightness Effect of Waterproofing Admixture Mixed Redispersible (재유화형 분말수지계와 규산질계 혼합형 구체방수재의 방수효과에 관한 연구)

  • 김무한;오상근;배기선;박선규;김용로
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.39-46
    • /
    • 2000
  • This study is to investigate the watertightness properties of waterproofing admixture mixed redispersible polymer and siliceous powder. Series I deals with change in micro-structure of mortar by waterproofing admixture according to the water/cement ratios of 0.5, 0.6, 0.7 and 0.8 Crystal growth in micro-structure was observed through SEM to estimate on the watertightness effect of it. SeriesII deals with watertightness properties of waterproofing admixture on water permeability coefficient, crack restoration capacity and carbonation depth. SeriesII deals with watertightness properties of waterproofing admixture on water permeability coefficient, crack restoration capacity and carbonation depth. The result of this study can be summarized as follows. 1) Fluidity of mortar and concrete was increased by adding waterproofing admixture. 2) From observation through SEM. Crystals grew larger and denser in micro-structure as fiberic crystalization. 3) Waterproofing admixture is good watertightness properties in a level of high water/cement ratios and long limit of time. 4) Crack restoration capacity was appeared and durability was progressed by waterproofing admixture.

A Study on the Determination of mix Proportion of Water-Permeable Concretes for Site Application (현장적용 투수성 콘크리트의 배합조건 결정에 관한 실험적 연구)

  • 김봉찬;은재기;김완기;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.130-135
    • /
    • 2000
  • The purpose of this study is to examine the physical properties of water-permeable concretes. The water-permeable concrete with cement-aggregate ratios of 1:3.5 to 1:6.0 and two type of coarse aggregate size of 8~13 and 13~18mm used OPC(ordinary portland cement) as a binder and superplasticizer are prepared, and then tested for flexural strength, compressive strength, compressive strength, continuous void percentage and coefficient of water permeability. It is concluded from the test result that the superior flexural and compressive strengths, coefficient of water permeability and continuous void percentage of water-permeable concretes that use OPC were obtained at cement-aggregate ratios of 1:3.2, 1:6.0 respectively, The water-permeable concretes with coarse aggregate of 8~13 and 13~18mm size used OPC as a binder havinga flexural strength of 24.81~45.56kgf/$\textrm{cm}^2$, 21.99~40.62kgf/$\textrm{cm}^2$, a compressive stength of 93.63~ 242kgf/$\textrm{cm}^2$, 114.8~191.7.kgf/$\textrm{cm}^2$, a coefficient of permeability of 0.59~1.85kgf/$\textrm{cm}^2$, 0.73~ 2.25kgf/$\textrm{cm}^2$, and a continuos void percentage of 16.6~26.32%, 13.52~24.35% respectively during 28 curing days.

  • PDF

Engineering Properties of Permeable Polymer Concrete for Pavement Using Polypropylene Fiber (폴리프로필렌섬유를 혼입한 포장용 투수성 폴리머 콘크리트의 공학적 성질)

  • Sung, Chan-Yong;Lee, Seung-Hoon
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.277-283
    • /
    • 2010
  • Research on permeable pavement like asphalt and concrete pavement with porous structure has been increasing due to environmental and functional need such as reduction of run off and flood. This study was performed to evaluate void ratio, permeability coefficient, and compressive strength of permeable polymer concrete (PPC) using crushed and recycled coarse aggregate that is obtained from waste concrete. Also, 6 mm length of polypropylene fiber was used to increase toughness and interlocking between aggregate and aggregate surrounded by binder. Binder and filler used were unsaturated polyester resin and CaCO3, respectively. The mix proportions were determined to satisfy the requirement for the workability and slump according to aggregate sizes 5~10 mm. In the test results, regardless of kinds of aggregates and fiber contents, the void ratio, permeability coefficient and compressive strength of all types of PPC showed the higher than the criterion of porous concrete that is used in permeable pavement in Korea. Also, strengths of PPC with increase polypropylene fiber volume fraction showed slightly increased tendency due to increase binder with increase of fiber volume fraction. Accordingly, polypropylene fiber and recycled coarse aggregate can be used for permeable pavement.

The Application of Piezocone Penetration Test at Inchon International Airport (인천국제공항지역의 피에조콘조사와 결과의 적용)

  • 김종국;성기광;김학중;김영웅
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.2
    • /
    • pp.115-123
    • /
    • 2000
  • Piezocone Penetration Test has been performed in the soft ground over the site preparation area at Inchon International Airport(IIA). With the pore pressure dissipation test results, the changes in the permeability and the coefficient of consolidation in clayey soil were checked and the differences of the undrained shear stength verified the soft ground improvement effect from vane test and piezocone test both before and after the improvement. From the results, thin sand seam was found and this caused a big difference in the coefficient of permeability and consolidation. The coefficient of consolidation was high in the upper marine deposit and relatively low in lower marine deposit. It was found that the reduction of void ratio by preloading resulted in the reduction of coefficient of consolidation after the ground improvement. In addition, there were some variations of undrained shear strength when the number of 15 or 18 was used as the coefficient of piezocone(Nkt). However, when the average value of undrained shear strength calculated using Nkt=10 was applied, the result indicated the similar average value with the result of vane test and the increasing rate of strength( Δsu/Δ$\sigma$≒0.38) also showed the similar distribution.

  • PDF