• 제목/요약/키워드: Permanent charge

검색결과 55건 처리시간 0.031초

Characteristics of an HTS SMES for Solar Power System

  • Kim Woo-Seok;Lee Seung-wook;Hahn Song-yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권2호
    • /
    • pp.44-46
    • /
    • 2005
  • A SMES can be a perfect alternative energy storage device to the chemical batteries which are needed by most of the renewable energy supply systems. The chemical battery storage system is so expensive to maintain and causes another environmental problem because they are not recyclable. But, SMES has semi-permanent lifetime and no environmental problems cause it only need coolants which is non flammable, clean and recyclable gas. In order to verify the feasibility of a SMES for the renewable electrical power supply system, electrical characteristics of a test SMES coil with the photovoltaic power system were analyzed in this paper. Simulation results show that we can charge 40 amps of current in test SMES coil using solar power system. The experimental verification will be performed just after development of the peak power tracking system for the solar system.

Optimization of Battery Storage Capacity with Min-Max Power Dispatching Method for Wind Farms

  • Nguyen, Cong-Long;Kim, Hyung-Jun;Lee, Tay-Seek;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.238-239
    • /
    • 2013
  • It is a crucial requirement to utilize an economical battery capacity for the wind energy conversion system. In this paper, the optimal BESS capacity is determined for the wind farm whose dispatched power is assigned by the min-max dispatching method. Based on a lifetime cost function that indicates the BESS cost spent to dispatch 1kWh wind energy into grid, the battery capacity can be optimized so as to obtain the minimum system operation cost. Moreover, the battery state of charge (SOC) is also managed to be in a safe operating range to ensure the system undamaged. In order to clarify the proposed optimizing method, a 3MW permanent magnet synchronous generator (PMSG) wind turbine model and real wind speed data measured each minute are investigated.

  • PDF

소형 직접구동형 풍력발전기의 최대 출력제어 (Maximum Power Control of Small Direct-Drive Wind Power Generator)

  • 김철호;이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.875-877
    • /
    • 2004
  • Research related to renewable energy is urgently required to cope with the depletion of fossil fuel and the environmental pollution. This paper deals with maximum power control of 1kW rating wind power generator. To implement direct-drive generator, axial flux permanent magnet generator is adopted to test the converter. The blade is attached to the surface of outer rotor disk. Generally wind power generator is operated under the rated wind speed. To capture maximum power at my given wind speed, the coordination of generator and converter is essential. Buck/Boost converter is designed to charge 24V battery and under the low wind speed it operates as boost converter.

  • PDF

XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형 (Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권2호
    • /
    • pp.357-364
    • /
    • 2005
  • 최근 들어 우리나라에서는 설치의 간편성과 높은 신뢰도를 가진 전력케이블의 사용이 증가하고 있다. 전력케이블은 출고 전에 IEEE std. 404-1993 시험을 거쳐 안정성을 확인하고 있지만 포설시 발생하는 접속부 내부의 결함으로 인하여 많은 문제가 발생하고 있다. 특히 불순물 혼입 또는 공극 발생시 고장율은 증가하게 된다 부분방전 검출은 포설 후 전력케이블의 상태를 관측할 수 있는 유용한 방법이다. 본 연구에서는 부분방전 특성을 평가하고자 케이블 접속재인 EPR과 케이블 절연체인 XPLE 사이에 인공 결함을 발생시킨 후 데이터 취득 시스템을 이용하여 $\Phi-q-n$ 특성을 검출하였으며, 부분방전의 정량적 해석을 위해 필요한 통계량을 계산하였으며, 신경망 모델을 적용하여 패턴 분석을 수행하여 $88\~96\%$의 구별이 가능하였다.

  • PDF

XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형 (Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권2호
    • /
    • pp.279-286
    • /
    • 2005
  • 최근 들어 우리나라에서는 설치의 간편성과 높은 신뢰도를 가진 전력케이블의 사용이 증가하고 있다. 전력케이블은 출고 전에 IEEE std. 404-1993 시험을 거쳐 안정성을 확인하고 있지만 포설시 발생하는 접속부 내부의 결함으로 인하여 많은 문제가 발생하고 있다. 특히 불순물 혼입 또는 공극 발생시 고장율은 증가하게 된다. 부분방전 검출은 포설 후 전력케이블의 상태를 관측할 수 있는 유용한 방법이다. 본 연구에서는 부분방전 특성을 평가하고자 케이블 접속재인 EPR과 케이블 절연체인 XPLE 사이에 인공 결함을 발생시킨 후 데이터 취득 시스템을 이용하여 $\Phi-q-n$ 특성을 검출하였으며, 부분방전의 정량적 해석을 위해 필요한 통계량을 계산하였으며, 신경망 모델을 적용하여 패턴 분석을 수행하여 $88\~96\%$의 구별이 가능하였다.

  • PDF

수퍼커패시터를 이용한 하이브리드 연료전지시스템에 관한 연구 (A Study on the Hybrid Fuel Cell System by using supercapacitor)

  • 윤성식;최원묵;김성훈;김태규;안호균
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.589-592
    • /
    • 2011
  • 본 논문에서는 급속 충 방전이 가능하고 높은 충 방전 효율 및 반영구적인 사이클 수명 특성으로 보조 배터리나 배터리 대체용으로 사용될 수 있는 차세대 에너지 저장장치인 수퍼커패시터 모듈과 양방향 직류-직류 컨버터를 이용한 연료전지 시스템에 관한 연구를 진행하였다. 수퍼커패시터의 전압 불균형으로 인한 과전압 방지를 위하여 병렬 모니터 회로를 제작하고, 시뮬레이션과 실험을 통하여 동작 성능을 확인하였다. 제작한 수퍼커패시터 모듈을 바탕으로 하이브리드 연료전지 시스템을 구성하였고, 구성된 시스템에 부하장치를 연결하여 연료전지 시스템의 동작 성능을 시험 및 평가하였다. 이를 통하여 연료전지 발전시스템의 느린 동특성, 부하에 따른 출력전압 변동, 에너지 저장 능력 결핍과 같은 단점을 보완하여 연료전지 발전 시스템의 성능을 향상시킬 수 있었다.

  • PDF

플라즈마발생기의 이온분율 측정 장치 설계 및 제작 (The design and fabricationt for ion fraction measurement of plasma generator)

  • 이찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

대구 지하철 구간내 선형 변동에 따른 소음 및 진동 저감 방안 연구 (The optimal control methods to reduce the environmental hazards surrounding the YoungNam Uni. Rotary of City Taegu constructing Subway Line No.1)

  • 지왕률;최재진;강상수;강대우
    • 터널과지하공간
    • /
    • 제7권2호
    • /
    • pp.116-129
    • /
    • 1997
  • The objective of this study is to predict the minimization effect of the noise and vibration during the construction and the train operation regarding to the design modification of the Taegu Subway Line No. 1. It was suggested optimal control blasting methods to reduce the causing vibration Nuance to the resident in City Taegu and also proposed the better governing method to decrease the environmental hazard to the near buildings and residents during the train operation. When the high-density gaseous reaction of explosion products exerts a high pressure in motion outward, a dynamic stress field will be created in the surrounding buildings. Therefore, in the region close to the charge, permanent damage begins to occur at a great critical level of partial velocity, that is difficult from different structure as working conditions. It is reliable to predict that the damages could be reduced if we know the peak velocity and the exact reasons through the conducting of detail studies of structural analysis of the related buildings with the optimal blasting designs. A blasting technique should be deemed to take advantage of the reduction of damage of the surrounding rocks and structures to improve the in-city blasting. This is a typical in-city blasting operation where success depends on closely controlling the ground vibrations in case of better designed blasting methods. There are techniques that can be applied to prevent large vibrations from damaging the important buildings through the Route Modification of the Taegu Subway Line No. 1.

  • PDF

J2EE 패턴기반 EJB 빈 클래스의 다중 DB 연동에 대한 설계 및 구현 (Design and Implementation of Multiple DataBase Access using Choice Method for EJB Bean Class Based on J2EE Pattern)

  • 이돈양;송영재
    • 정보처리학회논문지D
    • /
    • 제11D권1호
    • /
    • pp.143-152
    • /
    • 2004
  • 최근에 객체지향 소프트웨어를 설계하거나 구현방법으로 EJB 기반의 소프트웨어 개발이 많이 이용되고 있다. 일반적으로 EJB 기반 어플리케이션에서는 데이터베이스를 이용한 영속적인 데이터를 사용하는 경우가 대부분이다. 본 논문에서는 서버 측 작성 프로그램 중 엔티티빈 클래스에서 담당하는 데이터베이스 엑세스에 관련된 부분을 J2EE의 DAO 패턴을 이용하여 클래스를 각각 분리하였다. 이는 기존의 패턴 방법과는 큰 차이는 없으나, 동일 패턴내의 공통의 클래스들을 합성이 가능하도록 설계하였다. 그리고 생성된 각각의 DBMS 클래스들은 다른 엔티티빈 클래스에서도 사용이 가능하게 할 뿐만 아니라 여러 DBMS 환경에서도 Data Source를 추가적인 프로그램의 변경이나 작성 없이 연동이 가능하도록 하고 있다.

오존발생시스템을 이용한 하천수질 개선기법 (Techniques of Water Quality Improvement by Using Ozone Generation System)

  • 김민영;류재욱;이승윤;지홍기
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.2122-2126
    • /
    • 2008
  • With the degradation of water quality and, at the same time increased water usage, the sources of high quality, for examples, river/stream, municipal reservoir, wells, artisan and surface water, are diminishing. Therefore, the importance of water quality has been emphasized over the years through publications and various literature sources. Even though considerable research has resulted in significant strides for providing interpretive information and mitigation strategies for improvement of waters, the quality of which is still questionable. This study aims to propose a completely independent self-contained system for purifying waters, solar-powered ozone generator. It is a semi-permanent and cost effective environmental solution. Functions of ozone treatment are: 1) to maintain oxidative flexibility, 2) remove harmful chemicals, wastes, and other substances, and 3) prevent epizootic microbial outbreaks. Recent advances in technology have allowed the development of the practical, self-contained and independent solar powered device. Solar electrical producing panels that charge batteries are the key to using these systems anywhere electrical power is not available. This paper invites the readers to examine the problem and consider the viable, proven solution the solar powered ozone purifying system. This paper also introduces basic concept and background of solar powered ozone generators and examine its feasibility for improving water quality in rivers and streams.

  • PDF