• Title/Summary/Keyword: Permanent anchor

Search Result 35, Processing Time 0.024 seconds

Design Method and Evaluation of the Applicability of the Complex AAM Permanent Anchor (복합 AAM 영구 앵커의 설계법 및 적용성 평가)

  • Lee, Hyuk-Jin;Jung, Dae-Hoon;Kim, Jin-Hong;Lee, Chong-Ha;Kim, Hong-Taek
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.538-541
    • /
    • 2007
  • In this study, the complex AAM permanent anchor was introduced and the design method for the complex AAM permanent anchor was showed by examining the relationship of the forces applied to the anchor, the ground failure, the loads inducing the tensile failure between the anchors, etc. In order to understand the behavioral characteristics of the complex AAM permanent anchor, the field pullout test was carried out, and the results obtained with the design method were compared with those of the field pullout test.

  • PDF

Ultimate Uplift Capacity of Permanent Anchor Embedded in Weathered Rock (풍화암에 근입된 영구 앵커의 극한인발력)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo;Kim, Jin-Hwang
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.195-203
    • /
    • 2001
  • The purpose of this study is to estimate ultimate uplift capacity of permanent anchor which was cast into weathered rock. The ultimate uplift capacity was estimated from the load-displacement curve of four different anchors which have different bond length. The creep test was performed for 15minutes under the maximum load of each step in order to understand the load-transfer property of permanent anchor and to decide which anchor to choose. The destruction range of soil due to the changes in load was estimated by installing dial gauge on the ground which was cast into the weathered rock. Ultimately, the study on the behavior of the anchor case into the weathered rock was performed by comparing and analyzing the estimated result of the UUC obtained by the full scale pull out test in the field with the exsting theoretical and practical results of soil and rock anchor.

  • PDF

Experimental Study for the Structural Stability of Permanent Anchor (영구 앵커의 구조적 안정성에 관한 실험적 연구)

  • Yoo, Nam-Jae;Park, Byung-Soo;Park, Chan-Deok;Hong, Young-Gil;Lee, Jong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.87-98
    • /
    • 2006
  • This paper is an experimental result of performing the prototype of anchor tests in field to investigate the ultimate uplifting capacity of permanent anchor embedded in weathered rock. For prototype of actual anchor test in situ, four grouted anchors having various anchor lengths were installed in field and their ultimate uplift capacities were obtained by analyzing test results of load-displacement curves obtained from field uplift tests. On the other hand, creep tests, applying pull-out loading at the stage of the maximum loading during 15 minutes, were performed to investigate ultimate resisting capacity of anchor so that the values of creep rate at the ultimate loading conditions were evaluated. Dial gauges were installed on the surface of ground to measure the vertical displacement distribution from the anchor so that the failure mechanism of permanent anchor embedded in weathered rock and failure boundary of ground during application of loading were evaluated.

Application for Environment-friendly Retaining Wall Method Composed with Permanent Ground Anchor and Vertical Precast Panel in Cutting Slope Area (영구앵커와 연직 프리캐스트패널을 사용한 절토사면 친환경옹벽공법의 적용사례)

  • Nam, Hong-Ki;Jung, Hong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.87-96
    • /
    • 2010
  • PAP method is a combined measures which consist a anchored retaining wall method with permanent ground anchors and vertical precast concrete panels, step by step on the slope surface. And soil is back filled between slope and vertical precast panels. Therefore, this method is more effective than any other ground anchor reinforcing methods of slope stability, for example cross type concrete block ground anchor or buttress concrete block ground anchor method. Because of increasing effective anchor force and green tree planting.

  • PDF

A Study on the Long-Term Behavior Characteristics of Buoyancy-Resistant Permanent Anchor (부력저항 영구앵커의 장기거동 특성에 관한 연구)

  • Huh, Byungjoo;Kim, Chanki;Jung, Yonggun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.27-35
    • /
    • 2010
  • The structures built under the groundwater level are affected by the buoyancy force, which is hydrostatic pressure in the up direction. Recently, buoyancy-resistant anchor method has been applied in many cases of the construction of the important structure of large size, which is built under the groundwater level so that it takes high uplift pressure. Even if the construction cost of the method is very high, it surely increases the safety rate. However, the diagnosis of the performance of the buoyancy-resistant permanent anchor and the investigation of resistance mechanism are still insufficient. Especially, the long-term behavior of the anchor has not been studied well due to the difficulty in observation procedure. The contribution of this paper is the establishment of reasonable design methodology. We have measured anchor axial forces for 10 years after the construction, by using an automated measurement and a manual measurement by establishing a load cell in anchor head. Through the data collected from the measurements, we analyze the construction-step behavior of the anchor according to the self-weight variation of the building and the long-term behavior (i.e. movement within 10 years after the construction) of the anchor according to the passage of time.

A Applicability Study on Single Grouted Column Method (C-RJP Grouting) for Buoyancy-Resistant Permanent Anchor in Highly Permeable Volcanic Clastic Zones (투수성이 높은 화산쇄설층에서 부력앵커 시공을 위한 단일공 차수공법 (C-RJP Grouting)의 적용성에 관한 연구)

  • Jung, Yonggun;Chae, Youngsu;Park, Byunghee;Kim, Jeongryeol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.5-12
    • /
    • 2015
  • In this study, buoyancy-resistance permanent anchor was considered to prevent uplift pressure of a building structure. However, this test was failed to put anchor body in the boring hole because of the rapid outflow of ground water and coefficient of permeability. In addition, the hole where the anchor body was forcefully inserted constantly flew the sea water and cement. And it was found that anchor was not settled in the ground. In order to solve this problem, jet grouting method was applied to block the ground water and the single grouted column method was chosen to install the buoyancy-resistance permanent anchor. In this paper, the single grouted column method was applied with the general jet grouting methods and grout material was fixed by 3-field tests. These tests confirmed the effect of permeability and ground improvement with field permeability test by core sampling, Standard Penetration Test (SPT) and unconfined compression test. Confirming the stability of the buoyancy-resistance permanent anchor with installation and tension test, application of the single grouted column method in the volcanic clastic zones was verified.

Applicability of the Tensile Test Performance Evaluation Baseline for Ground Anchors (지반앵커에 대한 인장시험 성능평가 기준선의 적용성 고찰)

  • Kim, Dae Gun;Park, Tae Kwang;Park, Lee Keun;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.8
    • /
    • pp.75-84
    • /
    • 2022
  • Currently, tension ground anchors are divided into temporary and permanent based on their purpose and period of use, and their performance evaluations are presented separately. Therefore, applying the current performance evaluation's upper and lower limits to practice seems reasonable. However, because compression ground anchors have been mainly used as permanent, performance evaluation corresponding to permanent is conducted without distinction between temporary and permanent. This evaluation is a strict standard for ground anchors used as temporary, including the removal type. Because of examining the existing performance evaluation for the compression ground anchor, the lower limit can be applied without distinguishing between the temporary and permanent. However, the upper limit should be presented separately for the temporary and permanent. In applying the upper limit, it is necessary to adjust the upper limit of the anchor considering the anchored ground condition (rock or soil), the period of use, and particularly whether the load-displacement curve maintains the elastic state.

Fast and Seamless Handoff Control in Wireless ATM Networks (무선 ATM 네트워크에서 빠르고 매끄러운 핸드오프 제어)

  • Koh, Jae-Young
    • Convergence Security Journal
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2007
  • We propose a distributed anchor Crossover Switches (CX) searching algorithm to play an important role in ensuring fast and seamless handoff control in wireless ATM networks. Within networks that are grouped together, connection management is done for each group by anchor switches, and Permanent Virtual Circuit (PVC) with a narrow bandwidth is assigned between anchors for exchange of information. The proposed algorithm enables quick searching of a targeted CX, makes management of the overall network easier, and reduces system overhead or propagation delay time, thus providing fast and seamless handoff.