• Title/Summary/Keyword: Permanent Roof

Search Result 15, Processing Time 0.02 seconds

A Study of Investigation the Actual conditions on Housing and Facilities for Korean Native Goat (흑염소 축사시설에 관한 실태조사 연구)

  • 최순호;정광화;조영무;강희설;김원호;김영근
    • Journal of Animal Environmental Science
    • /
    • v.7 no.1
    • /
    • pp.13-20
    • /
    • 2001
  • This study was conducted to investigate the actual conditions on housing and facilities for goat. This investigation of the actual conditions was investigated by the style of farm which was divided into sideline scale and speciality scale included 47 farms. The results are summarized as follows: Rearing scale was 48.9% for 50-100 heads per farm. Rearing type was 46.8% for grazing type and 53.2% for barn type. Housing type was 27.7% for simple frame housing and 72.3% for permanent housing. Pipe was used 80.8% with Pillar and Girder as the housing frame at farm. For the pipe used in farm, 27.7% of them was used for simple frame housing. Side wall was composed of cement and winch curtain to be 29.8%, slate roof to be 40.4%, pipe partition to be 38.3%, and cement floor to be 51.1%. Materials of feeding trough were wood and Zinc grater to be 41.5%, respectively. Type of feeding trough was square to be 70.2%. The feeding trough was located in barn to be 48.9%. Material of water supply facilities was plastic to be 87.2%. Type of water supply facilities was mostly square to be 76.6%. Water-trough was located in playground to be 48.9%. Parturition facilities were consisted of partition structure by group to be 42.5% and were mainly composed of pipe and wood. 46.8% of the barn did not have delivery room in the farm.

  • PDF

A Study on the Characteristics of Space organization of Renzo Piano's Museum Projects (렌조 피아노(Renzo Piano)의 미술관건축 공간구성 특성연구)

  • 이성훈
    • Korean Institute of Interior Design Journal
    • /
    • no.17
    • /
    • pp.65-72
    • /
    • 1998
  • This study intends to analyze the various spatial structures and characteristics of the museum based on the two of the Renzo Piano's recent projects Menil Collection '||'&'||' Museum and Beyeler Foundation Museum Which defined the direction of the "Third Generation" in museum architecture with reference to the quality of spatial experience and design applications. Comparison and analysis were done on the basic spatial organization floor layout accessibility exhibition area lighting plan and circulation between the two museum. Through the itemized common characteristics of the museum the architect's proposal on meaning and direction of the new museum architecture can be viewed. The contemporary museums distinguish themselves quite clearly from their predecessors and this applies both to their own form and to their spatial organization. As the public demands and requests toward the museum building facility expand everyday the architect must respond by providing multiple types of space where people can experience different atmosphere in each area. One concept he used to create multi experienced area was manipulation of the natural light using by the state-of-the-art techniques of the light filtering system and multi-layering roof system to protect the valuable collections against the direct sunlight. But mainly it was to prove his strong belief in "architecture of light" by creating space with minimized meaning by purposely distinguished area in order to provide maximum support to the physical value of the collection " The connection with nature" is another concept which Piano used to provide the public a tranquil experience through out the architecture which engages in a lively dialogue with art. In spatial organization Piano concerned on functionality which not only concentrated on the visitor's point of view but also on the museum staff's comfort. Unlkie the traditional museum he alternates various size of exhibition areas for spatial hierarchy. Specially the spatial flexibility that the temporary exhibition areas are able to be expanded to the permanent exhibition areas by adjoining t재 spaces differentiate Piano's new museum from the rest. museum from the rest.

  • PDF

Two-level control system of toggle braces having pipe damper and rotational friction damper

  • Ata Abdollahpour;Seyed Mehdi Zahrai
    • Structural Engineering and Mechanics
    • /
    • v.86 no.6
    • /
    • pp.739-750
    • /
    • 2023
  • This study examines the two-level behavior of the toggle brace damper within a steel frame having a yielding pipe damper and rotational friction damper. The proposed system has two kinds of fuse for energy dissipation in two stages. In this mechanism, rotational friction damper rather than hinged connection is used in toggle brace system, connected to a pipe damper with a limited gap. In order to create a gap, bolted connection with the slotted hole is used, such that first a specific movement of the rotational friction damper solely is engaged but with an increase in movement, the yielding damper is also involved. The performance of the system is such that at the beginning of loading the rotational friction damper, as the first fuse, absorbs energy and with increasing the input load and further movement of the frame, yielding damper as the second fuse, along with rotational friction damper would dissipate the input energy. The models created by ABAQUS are subjected to cyclic and seismic loading. Considering the results obtained, the flexibility of the hybrid two-level system is more comparable to the conventional toggle brace damper. Moreover, this system sustains longer lateral displacements. The energy dissipation of these two systems is modeled in multi-story frames in SAP2000 software and their performance is analyzed using time-history analysis. According to the results, permanent relocations of the roof in the two-level system, in comparison with toggle brace damper system in 2, 5, and 8-story building frames, in average, decrease by 15, 55, and 37% respectively. This amount in a 5-story building frame under the earthquakes with one-third scale decreases by 64%.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.

Analysis of Environmental Design Data for Growing Pleurotus ervngii (큰 느타리버섯 재배사의 환경설계용 자료 분석)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2005
  • This study was carried out to file up using effect and requirement of energy for environmental design data of Pleurotus eryngii growing houses. Heating and cooling Degree-Hour (D-H) were calculated and compared for. some Pleurotus eryngii growing houses of sandwich-panel (permanent) o. arch-roofed(simple) type structures modified and suggested through field survey and analysis. Also thermal resistance (R-value) was calculated for the heat insulating and covering materials of the permanent and simple-type, which were made of polyurethane or polystyrene panel and $7\~8$ layers heat conservation cover wall. The variations of heating and cooling D-H simulated for Jinju area was nearly linearly proportional to the setting inside temperatures. The variations of cooling D-H was much more sensitive than those of heating D-H. Therefore, it was expected that the variations of required energy in accordance with setting temperature or actual temperature maintained inside of the cultivation house could be estimated and also the estimated results of heating and cooling D-H could be effectively used far the verification of environmental simulation as well as for the calculation of required energy amounts. When the cultivation floor areas are all equal, panel type houses to be constructed by various combinations of materials were found to by far more effective than simple type pipe house in the aspect of energy conservation maintenance except some additional cost invested initially. And also the energy effectiveness of multi-span house compared to single span together with the prediction of energy requirement depending on the level insulated for the wall and roof area could be estimated. Additionally, structural as well as environmental optimizations are expected to be possible by calculating periodical and/or seasonal energy requirements for those various combinations of insulation level and different climate conditions, etc.