• Title/Summary/Keyword: Peristaltic Pump

Search Result 54, Processing Time 0.028 seconds

Feasibility of Streaming Potential Signal on Estimation of Solute Transport Characteristics

  • Kabir, Mohammad Lutful;Ji, Sung- Hoon;Lee, Jin-Yong;Koh, Yong- Kwon
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.2
    • /
    • pp.41-46
    • /
    • 2015
  • The drag of the excess charge in an electrical double layer at the solid fluid interface due to water flow induces the streaming current, i.e., the streaming potential (SP). Here we introduce a sandbox experiment to study this hydroelectric coupling in case of a tracer test. An acrylic tank was filled up with homogeneous sand as a sand aquifer, and the upstream and downstream reservoirs were connected to the sand aquifer to control the hydraulic gradient. Under a steady-state water flow condition, a tracer test was performed in the sandbox with the help of peristaltic pump, and tracer samples were collected from the same interval of five screened wells in the sandbox. During the tracer test, SP signals resulting from the distribution of 20 nonpolarizable electrodes were measured at the top of the tank by a multichannel meter. The results showed that there were changes in the observed SP after injection of tracer, which indicated that the SP was likely to be related to the solute transport.

Fine Flow Controlling Device for Medicine Injection (의료 약물주입용 미세 유량 제어 장치)

  • Cho, Su-Chan;Shin, Bo-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.51-55
    • /
    • 2021
  • The nurses manually carry out the intravenous therapy for the patients. Using an Arduino, the fine flow controlling device was invented to provide an ongoing patient care. The medication is injected through a peristaltic pump, and the amount of the solution is controlled with a RGB color sensor. The power of the device is supplied through the batteries. An amount of the injection is measured with LIG strain sensor fabricated by 355nm UV pulsed laser. This system will provide a better medical service.

Analysis of High-Resolution Manometry Results in LPRD Patients Who Do Not Response to PPI Medication (양자펌프 억제제에 반응을 보이지 않은 인후두 역류질환 환자에서 고해상도 식도 내압검사의 분석)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.23 no.1
    • /
    • pp.43-47
    • /
    • 2012
  • Background and Objectives : Laryngopharyngeal reflux disease (LPRD) originates from regurgitation of gastric contents to the laryngopharynx, and it is relatively common disease in otolaryngology. Proton-pump inhibitor (PPI) medication is frequently using treatment method in present time, but controversies exist regarding treatment for it. High-resolution manometry (HRM) system is a newly developed device that using 36 channels and pressure topography plotting program, checking the function and status of esophagus. The aim of this study was to evaluate clinical usefulness of HRM in LPRD patients who do not response to PPI medication. Materials and Method : From July 2009 to July 2010, a total of 99 patients who were suspected LPRD according to symptoms (Reflux Symptom Index >13) and laryngoscopic findings (Reflux Finding Score >7) were retrospectively enrolled in this study. Patients were consisted of 31 men and 68 women, the mean age was 51.8 years, the mean BMI was 22.46. Patients have taken PPI medication for 2 months, after medication, they performed HRM. Comparative analysis was performed with results of the difference in symptoms. Results : In 99 patients, 37 patients (37.4%) show not improvement of LPRD symptoms after PPI medication. Among them, 18 patients (48.6%) showed abnormal findings that were classified as Peristaltic dysfunction (38.9%), Diffuse esophageal spasm (11.1%), Relaxation impairment of LES (11.1%), Achalasia (5.6%), Hypotensive LES (11.1%), Relaxation impairment of UES (11.1%), Nutcracker esophagus (5.6%), Decreased resting pressure (5.6%). Other 62 patients (62.6%) show improvement of LPRD symptoms, 23 patients (37.1%) showed abnormal findings. Most common finding was Peristaltic dysfunction (43.4%) More prevalent abnormal findings of HRM were found in patients who revealed no response to PPI medication (48.6% vs. 37.1%), but it does not reach the statistical significance. Conclusion : Although statistical significances is not showed, the difference observed in the frequency of HRM abnormal finding between response and no response for PPI medication. It has been estimated that HRM may be used to determine differential diagnosis in patients with LPRD. Further studies in lager population containing normal controls will be needed to prove clinical usefulness.

  • PDF

Analysis of High-Resolution Manometry Results in LPRD Patients who do not Response to PPI Medication (양자펌프 억제제에 반응을 보이지 않은 인후두 역류질환 환자에서 고해상도 식도 내압검사의 분석)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.151-155
    • /
    • 2011
  • Background and Objectives : Laryngopharyngeal reflux disease (LPRD) originates from regurgitation of gastric contents to the laryngopharynx, and it is relatively common disease in otolaryngology. Proton-pump inhibitor (PPI) medication is frequently using treatment method in present time, but controversies exist regarding treatment for it. High-resolution manometry (HRM) system is a newly developed device that using 36 channels and pressure topography plotting program, checking the function and status of esophagus. The aim of this study was to evaluate clinical usefulness of HRM in LPRD patients who do not response to PPI medication. Subjects and Method : From July 2009 to July 2010, a total of 99 patients who were suspected LPRD according to symptoms (Reflux Symptom Index >13) and laryngoscopic findings (Reflux Finding Score >7) were retrospectively enrolled in this study. Patients were consisted of 31 men and 68 women, the mean age was 51.8 years, the mean BMI was 22.46. Patients have taken PPI medication for 2 months, after medication, they performed HRM. Comparative analysis was performed with results of the difference in symptoms. Results : In 99 patients, 37 patients (37.4%) show not improvement of LPRD symptoms after PPI medication. Among them, 18 patients (48.6%) showed abnormal findings that were classified as Peristaltic dysfunction (38.9%), Diffuse esophageal spasm (11.1%), Relaxation impairment of LES (11.1%), Achalasia (5.6%), Hypotensive LES (11.1%), Relaxation impairment of UES (11.1%), Nutcracker esophagus (5.6%), Decreased resting pressure (5.6%). Other 62 patients (62.6%) show improvement of LPRD symptoms, 23 patients (37.1%) showed abnormal findings. Most common finding was Peristaltic dysfunction (43.4%) More prevalent abnormal findings of HRM were found in patients who revealed no response to PPI medication (48.6% vs. 37.1%), but it does not reach the statistical significance. Conclusion : Although statistical significances is not showed, the difference observed in the frequency of HRM abnormal finding between response and no response for PPI medication. It has been estimated that HRM may be used to determine differential diagnosis in patients with LPRD. Further studies in lager population containing normal controls will be needed to prove clinical usefulness.

  • PDF

Combined Effects of VFA Composition of Rumen Fluid and Heat Exposure on General Clinical View and Insulin Secretion Response in Sheep (고온환경에 있어서 면양의 제일위내 VFA 조성비율이 일반임상소견 및 Insulin 분필반응에 미치는 영향 - VFA-TG 인공영양사육법의 응용 -)

  • 홍경선;정태영;좌야굉명;지하농랑;중와방야;안보계일
    • Journal of Animal Environmental Science
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • This study was conducted to investigate the combined effects of VFA composition of rumen fluid and heat exposure (30${\pm}$2$^{\circ}C$) on the general clinical view and insulin secretory response to glucose in sheep. The total infusion of nutrients was examined in sheep via the technique of continuous alimentation. Four adult Suffolk sheep fitted with a permanent ruminal cannula and a simple T-shaped duodenal cannula were used. A peristaltic pump was used to infuse the solutions of volatile fatty acid triglycerides (VFA-TG) consisting of 70 triacetin : 20 tripropionin : 10 tributyrin (low propionin division: LP) and 50 triacetin : 40 tripropionin : 10 tributyrin (high propionin division: HP) on the basis of energy and minerals into the rumen, and casein solution into the duodenum. The effects of heat exposure and type of the levels of VFA-TG solutions on the insulin secretory response to glucose in sheep were investigated by using hyperglycemic clamp (HGC) technique. The results obtained are summarized as follows: 1. During the heat exposure (latter half of the infusion period), respiration rate, heart rate and rectal temperature increased (P<0.01, P<0.01, P<0.05), but the levels of VFA-TG solutions (LP and HP division) did not affect the general clinical view except for the heart rate. 2. In the HGC technique, glucose infusion rate (GIR) and mean plasma insulin increments (MPII) tended to be ower in the heat exposure than in the thermoneutral environment, but no significant difference was found among the treatments. GIR and MPII remained unchanged between the levels of VFA-TG solutions. 3. In the HGC technique, ratio of MPII to GIR (MPII/GIR) which represents pancreatic ${\beta}$-cell response to glucose stimulation remained unchanged among the treatments.

PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method (3차원 곡관에서의 굴절률 일치법을 이용한 맥동 유동의 PIV 측정)

  • Hong, Hyeon Ji;Ji, Ho Seong;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.511-517
    • /
    • 2016
  • Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent $10^{\circ}$ from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

Effect of Intraruminal Sucrose Infusion on Volatile Fatty Acid Production and Microbial Protein Synthesis in Sheep

  • Kim, K.H.;Lee, S.S.;Kim, K.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.3
    • /
    • pp.350-353
    • /
    • 2005
  • Effects of sucrose supplement on the pattern of VFA production and microbial protein synthesis in the rumen were examined in sheep consuming basal diet of grass silage (2.5 kg fresh wt/d) that was provided in 24 equal meals each day by an automatic feeder. Four mature wethers were allocated to four experimental treatments in a 4${\times}$4 Latin square design with periods lasting 14 days. The treatments were (1) the basal diet, (2) supplemented with 150 g sucrose and 7.0 g urea, (3) 300 g sucrose and 13 g urea, and (4) 450 g sucrose and 20 g urea given as a continuous intraruminal infusion for 24 h. All infusions were given in 2 litres of aqueous solution per day using a peristaltic pump. The effect of sucrose level on rumen mean pH was significantly linear (p<0.01). There were not significant differences in the concentration of ammonia-N, total VFA and the molar proportions of acetate, propionate and butyrate with the level of sucrose infusion. The molar proportions of isobutyric acid (p<0.05) and isovaleric acid (p<0.001) were significantly reduced when the infused amount of sucrose was increased. The flow of microbial N was linearly (p<0.001) increased with sucrose and urea level. High levels of readily fermentable carbohydrate in a ration reduced the efficiency of microbial protein synthesis in the rumen. It was demonstrated that of the individual fatty acids, only the molar proportion of isovalerate showed a significant negative correlation (R2=$0.3501^{**}$) with the amount of microbial N produced and a significant positive correlation (R2=$0.2735^{**}$) with the efficiency of microbial growth.

Disinfection of harmful organisms for sea water using electrolytic treatment system (전해처리를 통한 해수의 유해생물 살균처리)

  • Park Sang-Ho;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.955-960
    • /
    • 2004
  • The treated ballast water from previous treatment contains microorganisms and pathogenic organisms in an electrolytic treatment system. The experimental methods included using a peristaltic flow pump placed upward on an electrode pole. Due to the reaction time, the hydraulic retention time indicated unlike microorganisms on the flow rate. In electrolysis, dioxide iridium-coated titanium (Ti/Ir02) and stainless steel plates were used for the anode and cathode, respectively. Current density controls make use of a DC power supply on 250V, 100Amper. Experimental use of a current density between 0.1 and 1.0A/dm2 was able to disinfect the microorganism (E. coli, Bacteria, Bacillus sp.) in seawater for 5 seconds of reaction time. The removal rate was approximately $90\%,$ while the current density was 2.0A/dm2 and the electrode distance was 75mm. This study shows that the electrolytic treatment system has a potential for the sterilization of ballast water.

Decellularized Bioscaffold of Pig Organs: A Tool for Patient-specific Organogenesis Using Induced Pluripotent Stem Cells (탈세포화 기법을 이용한 돼지 바이오 스캐폴드: 환자 맞춤형 장기재생을 위한 역분화 줄기세포 동물모델)

  • Park, Kyung-Mee;Kwak, Ho-Hyun;Nam, Hyun-Suk;Park, In-Chul;Jeon, Yong-Hwan;Park, Sung-Min;Lee, Seung-Tae;Woo, Jae-Seok;Woo, Heung-Myong
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.57-62
    • /
    • 2011
  • The shortage of transplantable kidneys has many efforts to regenerate bioartificial kidneys using transgenic animals and diverse kinds of scaffolds which are important tools for cell seeding. However, there are many limitations for clinical applications so far. Recently, decellularized bioscaffolds using animal organs come into spotlight because of its many superior advantages. In current study, we produced decellularized kidney bioscaffolds of pig which is an attractive animal as a clinical model for human. We decellularized pig kidneys with 1% SDS detergent solution using peristaltic pump systems for 12h. After decellularization process, the kidney bioscaffolds preserved intact 3D morphology including glomerular structure and almost DNA from pig was entirely removed. In addition, this process could preserve micro vascular network which is necessary for cell survival. Although, additional studies for recellularization and transplantation should be required, the decellular vascularized kidney bioscaffolds might have many potentials for kidney regeneration.

Impact of Complex Hemodynamics to the Management of ArterioVenous(AV) Fistula (동정맥루의 복합성 혈류학 소견이 그 관리에 미치는 영향)

  • Lee Byung-Boons
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.9-10
    • /
    • 2002
  • Human circulatory system between heart and tissue is not directly connected in normal condition but mandatory to go through the capillary system in order to fulfill its physiologic aim to deliver oxygen and nutrients, etc. to the tissue and retrieve used blood together with waste products from the tissue properly. When abnormal connection between arterial and venous system (AV fistula), these two circulatory systems respond differently to the hemodynamic impact of this abnormal connection between high pressure (artery) and low pressure (vein) system. Depending upon the location and/or degree (e.g. size and flow) of fistulous condition, each circulatory system exerts different compensatory hemodynamic response to this newly developed abnormal inter-relationship between two systems in order to minimize its hemodynamic impact to own system of different hemodynamic characteristics. Pump action of the heart can assist the failing arterial system directly to maintain arterial circulation against newly established low peripheral resistance by the AV fistula during the compensation period, while it affects venous system in negative way with increased venous loading. However, the negative impact of increased heart action to the venous system is partly compensated by the lymphatic system which is the third circulatory system to assist venous system independently with different hemodynamics. The lymphatic system with own unique Iymphodynamics based on peristaltic circulation from low resistance to high resistance condition, also increases its circulation to assist the compensation of overloaded venous system. Once these compensation mechanisms should fail to fight to newly established hemodynamic condition due to this abnormal AV connection, each system start to show different physiologic ${\underline{de}compensation}$ including heart and lymphatic system. The vicious cycle of decompensation between arterial and vein, two circulatory system affecting each other by mutually negative way steadily progresses to show series of hemodynamic change throughout entire circulation system altogether including heart. Clinical outcome of AV fistula from the compensated status to decompensated status is closely affected by various biological and mechanical factors to make the hemodynmic status more complicated. Proper understanding of these crucial biomechanical factors iii particular on hemodyanmic point of view is mandatory for the advanced assessment of biomechanical impact of AV fistula, since this new advanced concept of AY fistula based on blomechanical information will be able to improve clinical control of the complicated AV fistula, either congenital or acquired.

  • PDF