• Title/Summary/Keyword: Periapical film

Search Result 37, Processing Time 0.038 seconds

DIAGNOSIS OF MESIODENS BY $SCANORA^{(R)}$ ($SCANORA^{(R)}$를 이용한 Mesiodens의 진단)

  • Jeon, Hyung-Joon;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.490-493
    • /
    • 2000
  • Mesiodens are supernumerary teeth in the region of the maxillary central incisors, a condition which can lead to disorders of the dentition. Their presence may lead to disorders, such as delay in eruption of permanent teeth, development of dentigerous cysts, resorption of adjacent roots and eruption of a supernumerary tooth into nasal cavity. The optimal time for surgical intervention is controversial. Early diagnosis is important so as to enable good prognosis. Diagnosis primarily depends on x-ray films. Panorama film, occlusal film, periapical film have been used for detection of mesiodens. But, all of them have disadvantages. $SCANORA^{(R)}$ is a multimodal radiology system which utilizes the principles of narrow beam radiology and spiral tomography. Pre-programmed imaging procedure are provided for many dental situations An optional personal computer can be connected into the unit to help design the examination. We report two cases diagnosed by $SCANORA^{(R)}$. When compared with tube shift technique, it is simple and exact method of detecting mesiodens.

  • PDF

DIGITAL SUBTRACTION RADIOGRAPHIC EVALUATION OF THE STANDARDIZED PERIAPICAL INTRAORAL RADIOGRAPHS (규격화된 구내 표준 방사선사진의 계수 공제 방사선학적 평가)

  • Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.1
    • /
    • pp.125-136
    • /
    • 1993
  • The geometrically standardized intraoral radiographs using 5 occlusal registration materials were taken serially from immediate, 1 day, 2, 4, 8, 12, and 16 weeks after making the bite blocks. And the resultant images were digitally subtracted using the immediately taken film as reference images. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exal1ex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. the lesser the standard deviation, the better the quality of the subtracted images. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Histologic Study on the Effect of Two Types of Bovine Bone Powder in Extraction Socket of Beagle Dogs (성견 발치와에 매식한 2종의 Bovine Bone Powder가 치유에 미치는 영향에 관한 조직학적 연구)

  • Park, Tae-Seong;Lim, Sung-Bin;Chung, Chin-Hyung;Kim, Jong-Yeo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.527-538
    • /
    • 2000
  • Several extraction cases with advanced bone loss as a result of periodontal disease, root or labial bone fracture, extensive caries, and periapical lesions occur esthetic, functional problems and severe bone loss. Therefore, to treat these cases used several surgical methods and socket preservation among this therapies have been evaluated simple, effective and good prognosis in the implant placement. Socket preservation therapy have been used with barrier membranes or/and graft materials. Deproteinized bovine bone mineral have been evaluated ideal grafting materials. Recently, calcium-phosphate thin film coated bovine bone powders were developed in our country, but the study for these material wasn't reported. When two types of xenograft materials were implanted in extraction sockets of Beagle dogs, the effects of these were analyzed after 4 weeks and 8 weeks histological views. The results of this study were as follows. 1. In control groups, 4 weeks after implantation, the extraction sockets were filled with connective tissue which has dilated vessels and epithelial growth. And after 8 weeks, irregular connective bundles were observed. But new bone formation was not seen. 2. In Bio-Oss groups, epithelial growth was not seen and bone powder was covered with connective tissue fiber. New bone formation was found around the interproximal bone. There was no special change seen after 8 weeks, connective tissue fibers became more regular, and bone growth near bone powder was not made well. 3. In Ca-P BBP groups, epithelial cells didn't grow in the extraction sockets, there was a lot of new bone made around the bone powder after 8 weeks, new bone around bone powder was replaced with mature bone. It is thought that bone powder grafting into the extraction sockets is very useful for conservation of ridge, and Ca-P BBP is more effective in bone formation than Bio-Oss.

  • PDF

Radiographic evaluation of alveolar bone profile of maxillary anterior teeth in Korean young adult (한국인 성인의 상악 전치부 치조골 형태에 관한 방사선학적 연구)

  • Seo, Hyo-Seok;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.461-471
    • /
    • 2006
  • In order to achieve a satisfactory esthetic result of periodontal surgery or implant in maxillary anterior area, periodontists must be aware of normal alveolar bone anatomy. The purpose of this study was to evaluate the relationship of alveolar bone morphology to tooth shape and form. 78(mean age : 25 yrs) periodontally healthy volunteers participated in this study. Two maxillary central incisor and one lateral incisor were selected to study. With minimal local anesthesia, gutta-percha cone inserted to labial gingival sulcus of selected teeth just after bone sounding with periodontal probe. Metal ball (4mm diameter) attached to palatal fossa of central incisor. Then, periapical radiograph was taken according to long cone paralleling technique. After film scan, labial alveolar bone profile reproduced along interproximal bone and apical ends of gutta-percha cones on computer screen. By utilizing computer program, the distance from height of interproximal bone to the labial bone crest in central incisor-central incisor and central incisor-lateral incisor area was measured and converted to real distance by using vertical length of metal ball on film. After measuring crown length & width of central incisor, the 10 individuals ranked lowest GW/L ratio (crown width/length ratio) and the 10 ranked highest were selected as having a long-narrow(group N), or a short-wide(group W) form of the central incisors. Means of the distance from height of interproximal bone to the labial bone crest of group N, W were calculated and compared by means of independent t-test. The results were as follows: 1. Mean distance from the height of the interproximal bone to the labial bone crest was $3.5{\pm}0.7mm$ between two central incisor, and $2.8{\pm}0.6mm$ between central and lateral incisor. 2. Mean GW/L ratio of group N was 0.57, and group W was 0.8. Mean distance from the height of the interproximal bone to the labial bone crest of group N was higher than group W in both measured area(measurements of group N, W were $3.9{\pm0.2mm$ and $3.5{\pm}0.2mm$ between two central incisor, $3.0{\pm}0.2mm$ and $2.8{\pm}0.2mm$ between central and lateral incisor), but there were no statistically significant differences when the groups were compared. Within the limits of the present study, there was a tendency that subjects with long-narrow teeth have more scalloped alveolar bone profile than subjects with short-wide teeth in upper anterior area, but no statistically significant differences were found.

DIAGNOSIS AND EXTRACTION OF IMPACTED SUPERNUMERARY TEETH IN THE MAXILLA WITH 3D DENIAL-CT (3D Dental-CT를 이용한 상악 매복 과잉치의 진단 : 증례보고)

  • Kim, Su-Kyoung;Yang, Yeon-Mi;Baik, Byeong-Ju;Kim, Sung-Hee;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.91-98
    • /
    • 2006
  • Supernumerary teeth are teeth which result from the continued budding of the enamel organ of the preceding tooth or from excessive proliferation of cells. They are most often found in the maxillary anterior region. And they can be responsible for a variey of irregularities in the primary and transitional dentition. There are two morphological types of supernumerary teeth, supplemental and rudimentary. Supplemental teeth have normal shape and size. In contrast, rudimental teeth have abnormal shape and smaller size. Supplemental supernumerary teeth are most common in permanent lateral incisor area. Its extraction must be decided more carefully with differential diagnosis between normal teeth, because it has normal shape and size. We reports 3 cases of the normal incisor shaped teeth in the maxillary anterior region. In all cases, we used the 3D Dental-CT as well as the conventional plain film such as periapical, occlusal, and panoramic radiograph. Consequently, 3B Dental-CT was valualble to figure out the exact position and morphology of supernumerary teeth, to do more conservative surgery and to reduce surgery stress and time.

  • PDF

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.