• Title/Summary/Keyword: Perfusion scan

Search Result 136, Processing Time 0.029 seconds

Preoperative evaluation of quantitative perfusion lung scintigraphy in the patient with lung cancer (정량적 폐관류스캔에 의한 악성폐종양 환자에서의 수술전 평가에 관한 고찰)

  • 김원곤;서경필
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.94-100
    • /
    • 1984
  • The purpose of present study is to investigate the significance of preoperative evaluation with perfusion lung scintigraphy in patients with lung cancer. Lung scans with the use of macroaggregated human serum albumin labeled with technetlum-99m were carried out in 35 patients with lung cancer before thoracotomy at Seoul National University Hospital during the period from November 1981 to September 1983. The relationship between size of the perfusion defect as seen by perfusion lung scan and size of the mass lesion as seen radiologically was correlated with the presence of regional adenopathy and resectability. Among patients with a larger perfusion defect than mass lesion on chest X-ray film.86% were found to have regional lymph node involvement with 29% resectability, whereas among patients in whom a larger defect was not present only 14% had such extension of the disease with 93% resectability. The relative pulmonary arterial perfusion of affected lung was calculated from the counts of radioactivity recorded from affected lung on both anterior and posterior scans expressed as a percentage of the total counts in the scan. The mean relative pulmonary arterial perfusion of the inoperable group [34\ulcorner%] is significantly different from both that of the pneumonectomy group [39\ulcorner%] and that of the lobectomy group [48\ulcorner%].(p<0.01)

  • PDF

Thallium-201 Perfusion Scan in Peripheral Arterial Disease (말초성 동맥 질환에 있어서 $^{201}T1$을 이용한 말초혈관 관류스캔의 유용성)

  • Nah, Jung-Il;Woo, In-Sook;Kim, Deog-Yoon;Koh, Eun-Mi;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.192-199
    • /
    • 1991
  • Peripheral arterial disease, because of it's significant and prolonged morbidity and related mortality is a major medical and surgical problem. Contrast angiogram remains the essential standard for the anatomic demonstration of disease. It does not, however, provide data suitable for quantification or any evaluation of the microcirculation. For these reasons, radionuclide studies are playing an increasingly important role by not only confirming the diagnosis and offering objective data on the physiologic significance of anatomic lesions, but by offering prognosis of healing and prediction of therapeutic results. In addition, radionuclide procedures offer means to safely and repeatedly monitor response to therapy and long term follow up. The object of this study was to evaluate the clinical availability of $^{201}T1$ perfusion scan in patients with peripheral arterial diseases. We performed $^{201}T1$ perfusion scans in patients with five Buerger' s disease (10 legs), six DM gangrenes (12 legs) and classified three perfusion pattern groups. Finally we compared treatment modalities among each groups and compaired T1-201 perfusion scan findings with angiographic findings in six patients with Buerger's disease. The results were as follows: 1) Seven legs showed increased perfusion in stress image and normal or increased perfusion in resting image (type 1). Six legs showed decreased perfusion in stress image and improved in resting image (type II). Of total 13 legs, only 1 leg needed to amputation. 2) Three legs showed decreased perfusion in stress and resting image (type III), and subsequently all cases were received surgical amputation. 3) In six Buerger's disease patients, there were disagreements in two patients (2 legs) between $^{201}T1$ scan and angiography, in which angiograms were normal but $^{201}T1$ scans showed 'type II' perfusion patterns.

  • PDF

Evaluation of Hepatic Hemangioma by Tc-99m Red Blood Cell Hepatic Blood Pool Scan (간 혈관종의 Tc-99m 표지 적혈구 혈액풀 스캔)

  • Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.151-162
    • /
    • 2005
  • Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon omission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ("perfusion/blood pool mismatch") is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ("perfusion/blood pool match") is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinoma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera.

Perfusion Computed Tomography in Predicting Treatment Response of Advanced Esophageal Squamous Cell Carcinomas

  • Li, Ming-Huan;Shang, Dong-Ping;Chen, Chen;Xu, Liang;Huang, Yong;Kong, Li;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.797-802
    • /
    • 2015
  • Background: The purpose of this study was to prospectively evaluate the predictive value of perfusion computed tomography (CT) for response of local advanced esophageal carcinoma to radiotherapy and chemotherapy. Materials and Methods: Before any treatment, forty-three local advanced esophageal squamous cell carcinomas were prospectively evaluated by perfusion scan with 16-row CT from June 2009 to January 2012. Perfusion parameters, including perfusion (BF), peak enhanced density (PED), blood volume (BV), and time to peak (TTP) were measured using Philips perfusion software. Seventeen cases received definitive radiotherapy and 26 received concurrent chemo-radiotherapy. The response was evaluated by CT scan and esophagography. Differences in perfusion parameters between responders and non-responders were analyzed, and ROCs were used to assess predictive value of the baseline parameters for treatment response. Results: There were 25 responders (R) and 18 non-responders (NR). Responders showed significantly higher BF (R:34.1 ml/100g/min vs NR: 25.0 ml/100g/min, p=0.001), BV (23.2 ml/100g vs 18.3 ml/100g, p=0.009) and PED (32.5 HU vs 28.32HU, P=0.003) than non-responders. But the baseline TTP (R: 38.2s vs NR: 44.10s, p=0.172) had no difference in the two groups. For baseline BF, a threshold of 36.1 ml/100g/min achieved a sensitivity of 56%, and a specificity of 94.4% for detection of clinical responders from non-responders. Conclusions: The results suggest that the perfusion CT can provide some helpful information for identifying tumors that may respond to radio-chemotherapy.

Comparison between Myocardial Perfusion and Function in Rest State in Coronary Artery Disease - Dipyridamole $^{99m}Tc-MIBI$ SPECT and Rest Gated Blood Pool Scan - (관상동맥질환에서 휴식기의 심근관류 정도와 휴식기 심기능 변화의 비교 - Dipyridamole 부하 $^{99m}Tc-MIBI$ SPECT와 휴식기 Gated Blood Pool Scan -)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Bae, Sang-Kyun;Yang, Hyung-In;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 1992
  • Rest gated blood pool scan (Rest GBP scan) and dipyridamole $^{99m}Tc-MIBI$ SPECT were Performed in 34 patients with or suspected coronary artery disease. Both studies were performed within $2\sim32$ days (mean 8.1 days). A significant correlation was present between left ventricular ejection fraction (r= -0.7356, p<0.001) and peak ejection rate and peak filling rate in rest GBP scan and perfusion defect in MIBI SPECT. And there were acceptable correlations (0.05$26.2{\pm}10.8%$, severe hypokinesia, akinesia or dyskinesia in 16 regions: $78.2{\pm}23.7$, p<0.001). These data indicate there is a significant coupling between the degree of myocardial perfusion and the myocardial functional change in coronary artery disease.

  • PDF

A Single Left Lung Transplantation in Dog -One Case Report- (황견에서 좌측 폐이식수술 -1례 보고-)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.238-240
    • /
    • 1994
  • We performed post-operative hemodynamic evaluation and lung perfusion scan after left lung transplantation in dog. The heart & lungs were extracted from donor dog while the both lungs were flushed with 4oC Euro-Collin`s solution after heparinization & infusion of prostaglandin E1.In the recipient dog, anastomosis of the left atrial cuff was performed by continuous 4-0 Prolene everted suture, and bronchial anastomosis by telescope method with 4-0 Prolene continuous suture. The end-to-end anastomosis of left main pulmonary arteries was performed with continuous 6-0 Prolene suture. After closure of left thoracotomy incision, the lung perfusion scan was performed post operative 2 days for evaluation of the function of the transplanted lung which showed good perfusion. The dog was sacrificed in the post-operative 5 days for autopsy.

  • PDF

Hepatic Arterial Perfusion Scintigraphy with Tc-99m-Macroaggregated Albumin in Hepatocellular Carcinoma (Tc-99m-MAA를 이용한 간세포암의 경동맥 관류스캔)

  • Kim, Gang-Deuk;Sohn, Kwang-Joon;Min, Kyung-Yoon;Kwon, Young-Mi;Kim, Chang-Guhn;Noh, Byung-Suk;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.350-356
    • /
    • 1994
  • Purpose : Hepatic arterial perfusion scintigraphy with Tc-99m-macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma(HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and usefullness of HAPS. Materials and Methods : HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4-5 mCi of MAA mixed with 2ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1ml/sec. We analysed 21 HCCs over 2cm in diameter(average diameter; 6.4cm) and 17 of 21 HCCs were over 4cm in diameter(Table 1). CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Results : Three different pattern of tumor perfusion were observed in 16 patients with HCC (Table 2). 1) diffuse increased perfusion in 16 of 21(76%)(Fig. 1) 2) increased peripheral perfusion in 4 of 21(19%) (Fig. 2) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16(56%)(Fig. 4). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16(13%). There was no accumulation of radioactivity on RBC-blood pool scan in all six patients with HCC examined (Fig. 1). Conclusion : HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  • PDF

A Case of Hepatopulmonary Syndrome Diagnosed by $^{99m}Tc-MAA$ Perfusion Lung Scan ($^{99m}Tc-MAA$ 폐관류스캔으로 진단한 간폐증후군)

  • Oh, Hyung-Tae;Lee, Moo-Yong;Song, Il-Han;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.203-208
    • /
    • 2002
  • In patients with chronic liver disease, hepatopulmonary syndrome, the right to left shunt without previous pulmonary and cardiac disease, can develope and cause respiratory distress. Tools to prove shunt are contrast echocardiography, pulmonary angiography, and $^{99m}Tc-MAA$ perfusion lung scan. Among them, $^{99m}Tc-MAA$ scan is a simple and safe method detecting the right to left shunt. At the same time, quantitation of shunt amount is possible by this method. We report a case of hepatopulmonary syndrome confirmed by $^{99m}Tc-MAA$ scan and contrast echocardiography with review of literlatures.

Clinical Study of the Patients, in Whom Pulmonary Embolism was Suspected by Lung Perfusion Scan (폐 관류주사검사상 폐동맥 색전증 소견을 보인 환자의 임상적 고찰)

  • Lee, Gwi-Lae;Kim, Jae-Yeol;Park, Jae-Suk;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.889-898
    • /
    • 1997
  • Pulmonary Embolism can develop in variable conditions, and presents with nonspecific symptoms and signs. If diagnosis is delayed, it can be resulted in catastrophic results. Therefore, early diagnosis and adequate treatment is crucial in Pulmonary Embolism. Lung Perfusion Scan is useful screening test. Negative result can exclude pulmonary embolism. But, perfusion defects don't always mean pulmonary embolism. To find the better methods of interpretation of lung perfusion scan and To evaluate the clinical course and outcomes of the patients, in whom pulmonary embolism was suspected by lung perfusion scan, we reviewed the clinical records of 49 cases suspected by lung perfusion scan at Seoul National University Hospital during the period of January, 1995 to July, 1996. The results are as follows. First impression of cases in which PE was present at time of admission were pulmonary embolism (63%), heart diseases (26%), and pneumonia (11%) in orders. Underlying diseases of cases in which PE developed during admission were malignancy (36.5%), ICH (22.7%), sepsis (13.7%), and SLE (9.1%) in orders. The predisposing factors were operation (20%), cancer (16%), immobility (16%), connective tissue disease (16%), heart dis. (10%), old age (10%), and preg/pelvic dis. (8%) The results, of lung perfusion scan were HPPE 40 cases(26.8 %), IPPE 21 cases(14.1%), LPPE 88 cases (59.1%), and cases(%) of treatment in these cases were HPPE 34 cases(85%), IPPE 9 cases(42.9%), LPPE 0 case(0.0%). Treatments were heparin and warfarin (69.5%), heparin alone (8.2%), warfarin alone (2.0%), embolectomy (4.1%), thrombolytics (2.0%), IVC filter (2.0%), and no treatment (12.2%) In 34 cases (69.4%), follow up could be done, and 5 cases were recurred (10.2%). The causes of recurrence was incomplete anticoagulant therapy (3 cases) and recurrence of predisposing factor (2 cases). Expired case due to pulmonary embolism was one who was expired just before trial of thrombolytic therapy. Conclusion : Efforts should be made to shorten the interval from onset of Sx to Dx, ie, high index of suspision.

  • PDF

Extracardiac Uptake of Thallium-201 during Myocardial Perfusion Imaging with Pharmaeologic Vasodilation (심근관류 스캔중에 나타난 Thallium-201의 심장외 국소적 섭취)

  • Choi, Chung-Il;Kwak, Dong-Suk;Chung, Byung-Cheon;Park, Moo-Keun;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.65-71
    • /
    • 1992
  • Myocardial perfusion imaging with $^{201}Tl-chloride$ following exercise or vasodilator-induced hyperemia has been effective in detecting the presence of coronary artery disease. An increased lung uptake of thallium has been reported as a sensitive marker of severe and extensive coronary artery disease and associated with poor prognosis. Thallium has also been noted to concentrate in a variety of malignant lesions. We report 5 cases of extracardiac uptake of thallium during myocardial perfusion scan with pharmacologic vasodilation. Accumulation of thallium was found in the lesions of a breast cancer, a lung cancer, a Castleman's disease and 2 cases of thymoma. We believe that the presence of focal extracardiac uptake of thallium during myocardial perfusion scan should suggest the need for further clinical evaluation to detect the tumor and must differentiate the increased lung uptake of thallium due to left ventricular dysfunction in coronary artery disease.

  • PDF