• Title/Summary/Keyword: Performance variation

Search Result 4,195, Processing Time 0.04 seconds

The Variations of Performance Parameters for Small Scale Hydro Power Plant with Rainfall Condition (강우상태에 의한 소수력발전소 성능변수의 변화)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • New & Renewable Energy
    • /
    • v.4 no.3
    • /
    • pp.15-22
    • /
    • 2008
  • The effects of design parameters for small scale hydro power (SSHP) plants due to rainfall condition have been studied. The model to predict hydrologic performance for SSHP plants is used in this study. The results from analysis for rainfall conditions based on Weibull distribution show that the capacity and load factor of SSHP site had large difference between the variation of shape and scale parameter. Especially, the hydrologic performance of SSHP site due to variation of shape parameter varied more sensitive than the case of variation of scale parameter. And also, the methodology represented in this study can be used to decide the primary design specifications of SSHP sites.

  • PDF

Transistor Matching in 70 nm nMOS for RF applications (70 nm nMOS의 RF 적용을 위한 transistor matching)

  • Choi, Hyun-Sik;Hong, Seung-Ho;Jeong, Yoon-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.583-584
    • /
    • 2006
  • This paper presents transistor matching in 70 nm nMOS. To adopt radio frequency(RF) applications, the RF performance, especially the current gain cutoff frequency($f_T$), is examined experimentally through a wafer. It is proved that the RF performance variation of 70 nm nMOS is dependent to the device geometry, the total width(W). The RF performance variation of 70 nm nMOS is inversely proportional to square root of total width(W). Also, decreasing of the number of fingers($N_f$) is helpful to decrease the variation of 70 nm nMOS.

  • PDF

Analysis of Nonlinear Control Characteristic for the Parameter Variation of Vector Control-Fed Induction Motors (벡터제어-구동 유도전동기의 파라미터 변동에 대한 비선형 제어특성의 해석)

  • Shon, Jin-Geun;Suk, Won-Yeob;Song, Yang-Hoi;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.51-57
    • /
    • 2004
  • Vector control schemes are used in inverter-fed induction motor drives to obtain high performance. Crucial to the success of the vector control scheme is the knowledge of the instantaneous position of the rotor flux. However, the position of the rotor flux change with temperature and magnetic saturation of the motor. This variation cause deterioration of both steady state and dynamic operation of the motor drives. Performance degradation is in the form of input-output torque nonlinearity and saturation of the motor. Analytic expressions are derived to evaluate the effects due to parameter sensitivity. Also, dynamic response is shown by speed command with the variation of stator and rotor resistance.

The influence of the pre-sag of a railway contact wire to the current collection performance (200km/h급 전차선로에서 사전이도가 미치는 집전성능 영향 분석연구)

  • Cho, Yong-Hyeon;Lee, Ki-Won;Park, Chan-Bae
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.227-235
    • /
    • 2007
  • The railway catenary is softer in the middle of a span than at the end. This stiffness variation induce the vertical motion of a moving pantograph, which results in the large variation of contact forces. To reduce the vertical motion of a pantograph, we can introduce a pre-sag of the contact wire. The pre-sag changes merely equilibrium position of the contact wire. Because the pantograph must follow the sag added to the motion of the contact wire, the sag gives downward forces to the pantograph. If the pre-sag is proper, the variation of the vertical motion of the pantograph is reduced. However, excessive sag worses the current collection performance because the pantograph receives too large downward forces by the contact wire. The objective of the paper is to establish the theoretical basis to understand how the pre-sag affect the contact force variation and to propose the proper sag for the railway catenary for the train speed up to 200 km/h.

  • PDF

A Study on the Main Spindle Deformatin characteristics by the Tool Weight Condition (공구 중량조건에 의한 주축변위 특성연구)

  • 김종관
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.121-128
    • /
    • 1996
  • In order to examine spindle deformation characteristics that affects the performance of dynmic cutting acuracy due to tool weight variation in a experimental spindle. thermal deformation value of operrative spindle by the axial displacement and the radial run out was measured according to the rise of spindle temperature through the laps of operation time and the change of rotational speed under the tool weight variation. A qualitative summary is as follows ; 1) The results show that the tool weight affcets the spindle temperature variation in a experimental spindle. 2) Radial run out and axial displacement was measured according to the rise of the spindle temperature and the performance of dynamic cutting accuracy was affected by the tool weight variation. 3) Axial displacement is 1.3 times larger than the radial run out in a experimental spindle conditions. 4) Axial displacement is continuously elongated when the tool weight is repeatly exchanged since the spindle themal deformaion, however, when the same tool weight is used. the displacement is still constant.

  • PDF

Performance and modeling of high-performance steel fiber reinforced concrete under impact loads

  • Perumal, Ramadoss
    • Computers and Concrete
    • /
    • v.13 no.2
    • /
    • pp.255-270
    • /
    • 2014
  • Impact performance of high-performance concrete (HPC) and SFRC at 28-day and 56-day under the action of repeated dynamic loading was studied. Silica fume replacement at 10% and 15% by mass and crimped steel fiber ($V_f$ = 0.5%- 1.5%) with aspect ratios of 80 and 53 were used in the concrete mixes. Results indicated that addition of fibers in HPC can effectively restrain the initiation and propagation of cracks under stress, and enhance the impact strengths and toughness of HPC. Variation of fiber aspect ratio has minor effect on improvement in impact strength. Based on the experimental data, failure resistance prediction models were developed with correlation coefficient (R) = 0.96 and the estimated absolute variation is 1.82% and on validation, the integral absolute error (IAE) determined is 10.49%. On analyzing the data collected, linear relationship for the prediction of failure resistance with R= 0.99 was obtained. IAE value of 10.26% for the model indicates better the reliability of model. Multiple linear regression model was developed to predict the ultimate failure resistance with multiple R= 0.96 and absolute variation obtained is 4.9%.

Hydrologic Performance Characteristics Variation of Small Scale Hydro Power Plant with Variation of Inflow (유입량변화에 의한 소수력발전소의 수문학적 성능특성 변화)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.4
    • /
    • pp.393-398
    • /
    • 2010
  • The variation of inflow at stream and hydrologic performance for small scale hydro power (SSHP) plants due to variation of inflow have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow caused from rainfall condition. And another model to predict hydrologic performance for SSHP plants is established. Monthly inflow data measured at Andong dam for 32 years were analyzed. The existing SSHP plant located in upstream of Andong dam was selected and analyzed hydrologic performance characteristics. The predicted results from the developed models in this study show that the data were in good agreement with measured results of long term inflow at Andong dam and the existing SSHP plant. Inflow and ideal hydro power potential had increased greatly in recent years, however, these did not lead annual energy production increment of existing SSHP plant. As a results, it was found that the models developed in this study can be used to predict the primary design specifications and inflow of SSHP plants effectively.

Comparative Study on Resistance Performance of Icebreaking Cargo Vessel according to Hull Form Variation by using Synthetic Ice and Refrigerated Ice (합성얼음과 냉동얼음을 이용한 선형을 변화시킨 쇄빙상선의 저항특성 연구)

  • Lee, Seung-Ho;Kim, Moon-Chan;Chun, Ho-Hwan;Shin, Byung-Chul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.350-358
    • /
    • 2010
  • The present paper deals with the comparative study of resistance performance with refrigerated ice and synthetic ice according to the variation of hull form characteristics. The resistance test has been conducted in pack ice condition in each concentration condition. Stem angle has been chosen as main parameters for the variation of hull form characteristics. The correlation of performance between with the refrigerated ice and with the synthetic ice has been shown according to the variation for stem angles. The present study show the possibility of ice test in general towing tank with synthetic ice for the time-consuming research such as hull form optimization although that is confined in pack ice condition. The more parametric study for the properties of synthetic ice is expected to be conducted to have more close correspondence for the test results of refrigerated ice in near future.

The Performance Comparison of Frequency Translators Using RHTL and LHTL Phase Shifters (RHTL과 LHTL 형태의 위상변위기를 이용한 주파수 변환기 성능비교)

  • Han, Heejae;Park, Hongwoo;Kim, Hongjoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.371-375
    • /
    • 2014
  • In this paper, we compared the performances of the Right Handed Transmission Line (RHTL) and the Left Handed Transmission Line (LHTL) phase shifters as a frequency translator. Unlike other phase shifters, both phase shifters show a $0^{\circ}-360^{\circ}$ phase variation for a broadband frequency and compact in size which are ideal to use as a frequency translator. For the performance comparison, we fabricated both a RHTL and a LHTL phase shifter to cover 1.5 GHz - 2.4 GHz range with the whole $360^{\circ}$ phase variation. For the frequency range, a LHTL based frequency translator showed a much better performance whose Spurious Free Dynamic Range (SFDR) is 4dB - 17dB higher than the RHTL based frequency translator when the sawtooth modulation freqncy is 11 kHz. This is due to the linear phase-voltage variation of LHTL phase shifter. Furthermore, the LHTL phase shifter shows a less insertion loss and a insertion loss variation than the RHTL phase shifter. Overall, the LHTL based frequency translator outperformed RHTL based freqency translator.

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Heat Pump with a Variation of Compressor Speed and Water Flow Rate (압축기 용량 및 유량변화에 따른 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.143.1-143.1
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz, and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWT of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system optimized at higher refrigerant charge amount conditions.

  • PDF