• Title/Summary/Keyword: Performance and Efficiency Drop

Search Result 264, Processing Time 0.02 seconds

Tip Clearance Effect on Through-Flow and Performance of a Centrifugal Compressor

  • Eum, Hark-Jin;Kang, Young-Seok;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.979-989
    • /
    • 2004
  • Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency.

Numerical Study on the Flow Characteristics of Uniflow Cyclone (단방향 사이클론의 유동 특성에 관한 수치해석적 연구)

  • Yan, Zheng-Qi;Zhang, Shuo;Shin, Weon Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.77-83
    • /
    • 2020
  • A uniflow cyclone has simple structure with a single channel in one direction. The one directional particle removal enables the uniflow cyclone to have compact size and low pressure drop. However, it has low collection efficiency compared to conventional cyclones. In this study, the effect of primary geometry on the performance of a uniflow cyclone with swirl vane is numerically investigated for the design of high performance uniflow cyclone. It is found that as the vortex finder diameter is increased, the pressure drop and the collection efficiency are decreased. Also, the same trend is predicted when the vortex finder height is increased. The best collection efficiency is predicted to be obtained when the vortex finder height is equal to the diameter of a cyclone. Reducing the body height by half will increase the pressure drop by 41%. When the body height is decreased, the collection efficiency is first increased and then decreased. The best collection efficiency is obtained when the body height is 4~5 times the cyclone diameter. Overall, the particle collection efficiency is highest when the Dν/D is equal to 0.3. But, the pressure drop is as high as 1592 Pa. Considering both collection efficiency and pressure drop, the best design is when Dν/D, Hν/D, and Hb/D are equal to 0.5, 1, and 5, respectively.

Numerical Study on Tip Clearance Effect on Performance of a Centrifugal Compressor (익단간극이 원심압축기 성능에 미치는 영향에 관한 수치해석적 연구)

  • Eum, Hark-Jin;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.389-397
    • /
    • 2003
  • Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASC flow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on Performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected Performance equally. while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully.

A NUMERICAL STUDY ON PLATE HEAT EXCHANGER PERFORMANCE BY GAP BETWEEN CHEVRON PLATES (판 사이 간격에 따른 판형 열교환기 성능에 관한 수치해석 연구)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.347-354
    • /
    • 2009
  • Plate Heat Exchnager(PHE) has recently become widely adopted for cogeneration systems owing to its small installation space and high thermal efficiency. The gap between plates can be changed depending on its assemble type, i.e. gasket or blazing. The gap is known to affect thermal efficiency and working pressure drop in PHE with complicated geometrical features. Numerical simulation techniques have been developed to deal with PHE with complex configuration of chevron plates. The present study is aiming at identifying the gap effect on pressure drop and thermal efficiency of the PHE. The numerical simulation results show that the gap has relatively large effects on working pressure drop than thermal efficiency in performance of PHE.

  • PDF

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System (원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교)

  • Kim Sang-Do;Park Young-Ok;Kang Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

Performance of Automotive Cabin Air Filter for Passenger Cars (승용차용 Cabin Air Filter의 성능)

  • 박영옥;구철오;임정환;김홍룡;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.279-287
    • /
    • 1996
  • Pressure drop and fractional collection efficiency of automotive cabin air filters were examined to obtain the basic data for the development of high performance domestic cabin air filters. Pressure drop of MA-V100 was higher than that of VF-V100, and it increased with the air flow rate. VF-V100 had longer time to rise the critical pressure drop than that MA-V100 had. Total collection efficiency of MA-V100 for initial and dust loaded conditions was higher than that of VF-V100. Also, fractional collection efficiency of MA-V100 for the fine particles was higher than that of VF-V100. Particla size distribution for the minimum collection efficiency ranged from 0.02 $\mu$m to 0.04 $\mu$m for MA-V100 and it ranged from 0.02 $\mu$m to 0.15 $\mu$m for VF-V100.

  • PDF

Prediction of collection performance for a granular bed filter filled with various shapes of packing material (다양한 형상의 충전물로 채워진 충전층 집진기의 집진성능 예측)

  • Jae-Hyun Park;Myong-Hwa Lee
    • Particle and aerosol research
    • /
    • v.19 no.4
    • /
    • pp.145-154
    • /
    • 2023
  • Granular bed filters are widely used to remove particulate matter in flue gas and are filled with various shapes of packing material. The packing material plays an important role in determining the overall collection performance, such as pressure drop and collection efficiency. The pressure drop of a granular bed filter has been calculated using the Ergun equation, while the collection efficiency has been predicted using the log-penetration equation based on the single sphere theory. However, a prediction equation of collection efficiency for a granular bed filter filled with non-spherical packing materials has not been suggested yet. Therefore, in this study, three different shapes of packing materials (sphere, cylinder, and irregular) were prepared to propose a prediction equation. The pressure drop and collection efficiency in a granular bed filter filled with each shape of packing material were measured experimentally and compared with theoretically predicted values. We found that experimentally measured pressure drops matched well with values theoretically predicted using the Ergun equation considering the shape factor. However, experimental collection efficiencies were higher than theoretical ones predicted by the log-penetration equation using the single sphere theory. We modified the log-penetration equation by employing a shape factor and found a good relationship between experimental and theoretical collection efficiencies.

Protection against Aerosols by particulate Respirators and Fit Performance (방진마스크의 에어졸 방어효과와 밀착정도)

  • 한돈희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

Theoretical and experimental study for optimization method of particle removal fibrous filter used in ventilation system (입자 제거용 환기 필터의 설계 변수 선정 기법을 위한 이론 및 실험적 연구)

  • Jung, Yee-Kyeong;Noh, Kwang-Chul;Park, Jae-Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • Pressure drop and particle removal efficiency of two commercial fibrous medium filters were measured with 20~1,000 nm sized aerosolized KCl particles. Pressure drop and particle removal efficiency were also theoretically predicted and the results qualitatively agreed with the experimental data. For this given particle removal efficiency, a filter design method for obtaining minimum pressure drop (and therefore minimum fan power) was suggested in this study by selecting solidity and fiber diameter as parameters. Therefore, by carrying out theoretical and experimental approaches together, this paper introduced a way of finding conditions for low pressure drop and high performance of a fibrous filter, especially if the filter would be used in mechanical ventilation system.

  • PDF