• Title/Summary/Keyword: Performance Standard

Search Result 6,961, Processing Time 0.039 seconds

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.

A Study on Factors Affecting Nursing Students' Standard Precautions Compliance (간호대학생의 표준주의 수행에 미치는 영향요인 연구)

  • Ha, Hey-Jin;Kim, Eun-A
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.473-481
    • /
    • 2022
  • This is a descriptive research study attempted to identify the relationship between standard precautions knowledge, standard precautions attitude, social support, and standard precautions compliance of nursing students, and to identify factors influencing standard precautions performance. The subjects of this study were 170 nursing students from 3 universities located in G city. Data analysis was performed using the SPSS 24.0 program and was analyzed by multiple regression. As a result of the study, it was found that the factors affecting nursing students' compliance of standard precautions had a positive effect in the order of social support and knowledge of standard precautions. Therefore, it is necessary to develop a systematic educational strategy and program configured to enhance the standard precautions knowledge content and to positively recognize and reinforce social support in order to increase the standard precautions compliance of nursing students.

A Study on Leaking amount Test of Control Damper - For a Performance Based Designed of Smoke Control System - (제연댐퍼 누설량 시험에 관한 연구 - 제연시스템의 성능위주설계를 위하여 -)

  • Choi, Kyu-Chool;Song, Yun-Suk;Cha, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.131-137
    • /
    • 2009
  • This study measured smoke control damper leaking amount of condition of various kinds examination regarding AMCA Standard 500-D-98. As result of study establish because smoke control damper leaking amount performance curve that use tester data of engineering applies right design method of smoke control system and test method design, drawing examination, performance test and do so that right comprehension and performance about skill may be defined. Also user wishes to prove performance of smoke control system and construct smoke control system of reliable performance-based design derive smoke control damper quality improvement continuously selection of smoke control damper by performance judgment of performance curve.

Performance evaluation of Knowledge workers using median rank (중앙값 정리를 이용한 지식근로자의 성과평가에 관한 연구)

  • 이동철;오강탁;윤덕균
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2001.10a
    • /
    • pp.45-49
    • /
    • 2001
  • Success in Knowledge Management depends critically on the evaluation system that managers of an organization evaluate objectively performance of members of the organization. In particular, the differences in the standard of Performance evaluation used by managers in Governmental Institution or Agency of make an issue of the standardization of Performance evaluation. Therefore, in this paper we propose the alternative evaluation method, which minimizes the bias resulted from the different standards by measuring ranking of knowledge workers, instead of quantitative analysis, using Median Rank method in Reliability and verify our proposition using the analysis of examples.

  • PDF

Performance Comparison of Several Pitch Detection Algorithm in Speech Signal (음성신호의 피치 검출에 관한 알고리즘의 성능 비교)

  • 김대현;유광복;이광형
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1984.04a
    • /
    • pp.5-8
    • /
    • 1984
  • Several pitch detection algorithms are studied and compared with the standard pitch detector in a terms of some kinds of errors and each of speaders. Various types of errors are defined, and rank the performance of pitch detectors.

  • PDF

$FIXATE^{TM}$ G-100 POLYMER - A New Standard for Fixative Performance

  • F. Shuster
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.462-463
    • /
    • 2003
  • With Fixate$^{TM}$ G-100 polymer, a whole new world of styling product possibilities awaks you. Fixate$^{TM}$ G-100 polymer satisties the demand for high performance products that offer significant consumer perceptible benefits, while meeting the tormulator's needs for cost control and manufacturing efficiency.(omitted)ted)

  • PDF

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

Effect of the Hydrophilic Treatment of Polyolefin Separator on the Electrochemical Characteristics for Ni-MH Secondary Battery (폴리올레핀계 분리막의 친수화 처리방법에 따른 Ni-MH 2차 전지의 전기화학적 특성연구)

  • Song, Li-Gyu;Lee, Yun-Sung
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.263-266
    • /
    • 2013
  • It was investigated the electrochemical characteristics of the Ni-MH battery by hydrophilic process. For adopting the Ni-MH battery in water-electrolyte, polyolefin separator was processed the hydrophilic treatment. No treatment sample did not meet KS standard (KSC 8544) but hydrophilic treatment ones satisfied with the KS standard in electrochemical characteristics, such as discharge performance, retention capacity, and cycle performance. All hydrophilic treatment samples showed similar battery performances. Among them, sulfonation treatment sample exhibited the highest value in aspect of capacity retention rate (> 88%). Furthermore, fluoride treatment sample showed the best cycle performance during battery test. This sample maintained a good cycling performance until $1,480^{th}$ cycle, which was about 3 times as compared with that of KS standard (500 cycle).