• Title/Summary/Keyword: Performance Isolation

Search Result 1,065, Processing Time 0.027 seconds

Effects of the nonlinear behavior of lead-rubber bearings on the seismic response of bridges

  • Olmos, B.A.;Roesset, J.M.
    • Earthquakes and Structures
    • /
    • v.1 no.2
    • /
    • pp.215-230
    • /
    • 2010
  • The main objectives of this work were to investigate the effects of the nonlinear behavior of the isolation pads on the seismic response of bridges with rubber bearings, and to identify when base isolation improved their seismic performance. To achieve these objectives a parametric study was conducted designing a set of bridges for three different soil types and varying the number of spans, span lengths, and pier heights. The seismic responses (accelerations, displacements and pier seismic forces) were evaluated for three different structural models subjected to three earthquakes with different dynamic characteristics. The first represented bridges without base isolation; the second corresponded to the same bridges including now rubber bearings as an isolation system, with linear elastic behavior that shifted the natural period of the bridge by a factor of 2 to 4. In the third model the seismic response of bridges supported on lead-Rubber bearings was studied accounting for the nonlinear behavior of the lead. The results show clearly the importance of the nonlinear behavior on the seismic performance of the bridges.

A Performance Isolation Mechanism Considering SLA in High Available Heterogeneous Cluster Web Systems (SLA를 고려한 클러스터 기반 고가용성 이질 웹 시스템의 성능 분리 기법)

  • Kang, Chang-Hoon;Park, Kie-Jin;Kim, Sung-Soo
    • The KIPS Transactions:PartA
    • /
    • v.12A no.7 s.97
    • /
    • pp.613-620
    • /
    • 2005
  • To provide reliable differentiated service for internet clients, many studies on differentiated service are widely done. According to the types of the request of the clients in cluster-based web systems, SLA (Service Level Agreement) between service provider and the clients is considered. In this Paper, we study primary-backup web switch in the web systems that distribute the request of clients to each of web servers and also study performance isolation and admission control schemes of heterogeneous web systems which distinguish the servers into each different function domains. We analyze the availability, the response time and the performance of admission control through various simulated experiments on the proposed web systems.

Miniaturized Radio Frequency Choke Using Modified Stubs for High Isolation in MIMO Systems

  • Lim, Seonho;Choi, Woo Cheol;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.219-223
    • /
    • 2015
  • In this paper, a miniaturized radio frequency choke (RFC) using modified stubs is proposed to improve isolation characteristics in a multiple-input-multiple-output (MIMO) antenna system. The proposed RFC, based on the LC resonance, is designed to suppress the leakage current that leads to the degradation of antenna diversity performances in the MIMO antenna configuration. The proposed RFC is composed of two open stubs that are implemented on the top of the ground plane and miniaturized by adding a slit structure on the ground plane. The MIMO antennas are also designed to verify isolation performance in the LTE 2300 band (2,300-2,400 MHz). The MIMO antennas perform well with low reflection coefficient characteristics and high isolation characteristics in the whole LTE 2300 band. To evaluate the isolation in the MIMO system, the envelope correlation coefficient (ECC) is calculated, and the value is less than 0.08. The achieved ECC is regarded as a reasonable result for improving isolation performance in the frequency range of 2,300-2,400 MHz; also, radiation patterns of antenna elements are maintained regardless of the presence of RFC.

Verification of Launch Vibration and Shock Isolation Performance for Spaceborne Compressor Vibration Isolator with SMA Mesh Washer (형상기억합금 메쉬 와셔를 이용한 우주용 냉각기 진동절연기의 발사 진동 및 충격 저감 성능검증)

  • Lee, Myeong-Jae;Han, Je-Heon;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.517-524
    • /
    • 2014
  • Micro-vibration induced by on-board equipments such as fly-wheel and cryogenic cooler with mechanical moving parts affects the image quality of high-resolution observation satellite. Micro-vibration isolation system has been widely used for enhancing the pointing performance of observation satellites. In general, the micro-vibration isolation system requires a launch locking mechanism additionally to guarantee the structural safety of mission payloads supported by the isolation system with low stiffness under launch environment. In this study, we propose a passive launch and on-orbit vibration isolation system using shape memory alloy mesh washers for the micro-vibration isolation of spaceborne compressor, which does not require the additional launch locking mechanism. The basic characteristics of the isolator were measured in static and free vibration tests of the isolator, and a simple equivalent model of the isolator was proposed. The effectiveness of the isolator design in a launch environment was demonstrated through sine vibration, random vibration and shock tests.

Simultaneous Fault Isolation of Redundant Inertial Sensors based on the Reduced-Order Parity Vectors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2188-2191
    • /
    • 2005
  • We consider a fault detection and isolation problem for inertial navigation systems which use redundant inertial sensors. We propose a FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest the number of redundant sensors required to isolate simultaneous faults. The performance of the proposed FDI algorithm is analyzed by Monte-Carlo simulation.

  • PDF

Fault Isolation Filter Design Using Left Eigenstructure Assignment Scheme (좌 고유구조 지정기법을 이용한 고장분리 필터 설계)

  • 최재원;이대영
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.6
    • /
    • pp.695-702
    • /
    • 1998
  • In this paper, we propose a novel fault isolation filter design method using the left eigenstructure assignment scheme proposed by Choi et. al., The proposed filter shows good fault isolation performance with exact eigenstructure assignment. An eigenstructure assignment methodology which satisfies the required fault isolation conditions is also proposed. The proposed method guarantees that the corrupted m simultaneous faults can be isolated when the number of available output measurements are (m+1).

  • PDF

Fault Detection and Isolation using Singular Value Decomposition for Redundant Sensors System (특이치 분해를 이용한 중복 센서의 EDI 기법과 성능 분석)

  • 심덕선;양철관
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.364-370
    • /
    • 2004
  • In this paper, we propose a FDI method, which comes from singular value decomposition of measurement matrix fur redundant sensors. We analyze the performance of the proposed FDI method by comparing with the GLT method in two ways such as FDI performance and GN&C performance. Also, we propose a GN&C performance index by combining FDI and GN&C performance.

Application of Smart Base Isolation System for Seismic Response Control of an Arch Structure (아치구조물의 지진응답제어를 위한 스마트 면진시스템의 적용)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2011
  • Base isolation system is widely used for reduction of dynamic responses of structures subjected to seismic load. Recently, research on a smart base isolation system that can effectively reduce dynamic responses of the isolated structure without accompanying increases in base drifts has been actively conducted. In this study, a smart base isolation system was applied to an arch structure subjected to seismic excitation and its control performance for reduction of seismic responses was evaluated. In order to make a smart base isolation system, 4kN MR dampers and low damping elastomeric bearings were used. Seismic response control performance of the proposed smart base isolation system was compared to that of the optimally designed lead-rubber bearing(LRB) isolation system. To this end, an artificial ground motion developed based on KBC2009 design response spectrum was used as a seismic excitation. Fuzzy control algorithm was used to control MR damper in the smart base isolation system and multi-objective genetic algorithm was employed to optimize the fuzzy controller. Based on numerical simulation results, it has been shown that the smart base isolation system can drastically reduce base drifts and seismic responses of the example arch structure in comparison with LRB isolation system.

Simultaneous Optimization of Hybrid Mid-Story Isolation System and Building Structure (하이브리드 중간층 지진 격리 시스템과 빌딩 구조물의 동시 최적화)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.51-59
    • /
    • 2019
  • A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.

Estimation of the Isolator Displacement for the Performance Based Design of Nuclear Power Plants (원전 적용을 위한 면진장치의 성능기반 설계 변위 추정)

  • Kim, Jung Han;Choi, In-Kil;Kim, Min Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.291-299
    • /
    • 2014
  • There has been an increasing demand for introducing a base isolation system to secure the seismic safety of a nuclear power plant. However, the design criteria and the safety assessment methodology of a base isolated nuclear facility are still being developed. A performance based design concept for the base isolation system needs to be added to the general seismic design procedures. For the base isolation system, the displacement responses of isolators excited by the extended design basis earthquake are important as well as the design displacement. The possible displacement response by the extended design basis earthquake should be limited less than the failure displacement of the isolator. The failure of isolators were investigated by an experimental test to define the ultimate strain level of rubber bearings. The uncertainty analysis, considering the variations of the mechanical properties of isolators and input ground motions, was performed to estimate the probabilistic distribution of the isolator displacement. The relationship of the displacement response by each ground motion level was compared in view of a period elongation and a reduction of damping. Finally, several examples of isolator parameters are calculated and the considerations for an acceptable isolation design is discussed.