• Title/Summary/Keyword: Performance Facility

Search Result 1,535, Processing Time 0.036 seconds

Construction and Operational Experiences of Engineered Barrier Test Facility for Near Surface Disposal of LILW (중.저준위 방사성폐기물의 천층처분을 위한 인공방벽 실증시험시설의 건설 및 운전 경험)

  • Jin-Beak Park;Se-Moon Park;Chang-Lak Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.23-34
    • /
    • 2004
  • To validate the previous conceptual design of cover system, construction of the engineered barrier test facility is completed and the performance tests of the disposal cover system are conducted. The disposal test facility is composed of the multi-purpose working space, the six test cells and the disposal information space for the PR center. The dedicated detection system measures the water content, the temperature, the matric potential of each cover layer and the accumulated water volume of lateral drainage. Short-term experiments on the disposal cover layer using the artificial rainfall system are implemented. The sand drainage layer shows the satisfactory performance as intended in the design stage. The artificial rainfall does not affect the temperature of cover layers. It is investigated that high water infiltration of the artificial rainfall changes the matric potential in each cover layer. This facility is expected to increase the public information about the national radioactive waste disposal program and the effort for the safety of the planned disposal facility.

  • PDF

Sub-System Requirements of a Pressure-fed Hot-firing Test Facility for the Performance Assessment of a LRE Thrust Chamber (액체로켓엔진 연소기의 성능평가를 위한 가압식 연소시험설비의 구성 요구조건)

  • Lee, Kwang-Jin;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.94-102
    • /
    • 2011
  • Sub-system requirements of a pressure-fed hot-firing test facility for performance assessment of a Liquid Rocket Engine(LRE) thrust chamber using Liquid oxygen and kerosene were described. These requirements were based on the experience of construction and operation of the ground hot-firing test facility which was used for the development of the KSR-III and a 30 tonf-class LRE thrust chamber. So it is expected that this paper is used as a basic material and an itemized previous review statement for the design and construction of a large hot-firing test facility.

Sub-System Requirements of a Pressure-fed Hot-firing Test Facility for the Performance Assessment of a LRE Thrust Chamber (액체로켓엔진 연소기의 성능평가를 위한 가압식 연소시험설비의 구성 요구조건)

  • Lee, Kwang-Jin;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.63-71
    • /
    • 2010
  • Sub-system requirements of a pressure-fed hot-firing test facility for performance assessment of a Liquid Rocket Engine(LRE) thrust chamber using Liquid oxygen and kerosene were described. These requirements were based on the experience of construction and operation of the ground hot-firing test facility which was used for the development of the KSR-III and a 30 $ton_f$-class LRE thrust chamber. So it is expected that this paper is used as a basic material and an itemized previous review statement for the design and construction of a large hot-firing test facility.

  • PDF

Design of a Real-Time Facility Diagnosis & Complex Data Management System Using IT Convergence Technology (IT융합기술을 활용한 실시간 설비진단 및 복합정보 관리시스템 설계)

  • Kang, Moon-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.5
    • /
    • pp.53-60
    • /
    • 2014
  • With the rapid development of IT technology, recently, the development of IT convergence technology related to the facility diagnosis is prevalent, and the study for the efficient integrated management scheme is required to handle all relevant information, from the design to the maintenance, including the stage of repair. In this paper, an efficient scheme to process the complex data for the facility and its diagnosis is proposed based on IT convergence technique and the real-time complex data management is designed. In order to evaluate the performance of the proposed system, the real-time management system is designed for a particular facility, and the comparative results show the good performance of the proposed system.

Design and operation of the transparent integral effect test facility, URI-LO for nuclear innovation platform

  • Kim, Kyung Mo;Bang, In Cheol
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.776-792
    • /
    • 2021
  • Conventional integral effect test facilities were constructed to enable the precise observation of thermal-hydraulic phenomena and reactor behaviors under postulated accident conditions to prove reactor safety. Although these facilities improved the understanding of thermal-hydraulic phenomena and reactor safety, applications of new technologies and their performance tests have been limited owing to the cost and large scale of the facilities. Various nuclear technologies converging 4th industrial revolution technologies such as artificial intelligence, drone, and 3D printing, are being developed to improve plant management strategies. Additionally, new conceptual passive safety systems are being developed to enhance reactor safety. A new integral effect test facility having a noticeable scaling ratio, i.e., the (UNIST reactor innovation loop (URI-LO), is designed and constructed to improve the technical quality of these technologies by performance and feasibility tests. In particular, the URI-LO, which is constructed using a transparent material, enables better visualization and provides physical insights on multidimensional phenomena inside the reactor system. The facility design based on three-level approach is qualitatively validated with preliminary analyses, and its functionality as a test facility is confirmed through a series of experiments. The design feature, design validation, functionality test, and future utilization of the URI-LO are introduced.

On the Improvement of the Process by Analyzing Precision Diagnosis of Deteriorated Railroad Communication Facilities

  • Hwang, Sun Woo;Kim, Joo Uk;Park, Jeong Jun;Kim, Hyung Chul;Park, Jin Hyuk;Kim, Young Min;Lee, Gye Chool
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.136-144
    • /
    • 2021
  • Railroad Systems, which are national infrastructure industries, cause unexpected property and human damage if they fail to function while operating. Accordingly, railroad facilities supporting the railroad system are areas where high reliability and safety are required. However, it is time for systematic and scientific maintenance to be taken away from the traditional maintenance methods, as the nation's railroad facilities are now aging seriously. The purpose of this study was to secure the safety and reliability of the aging railroad communication facilities and to improve their performance. The research subjects were selected as a precision diagnosis process for railroad communication facilities, and improvement points were derived through detailed precision diagnosis process analysis. It is deemed that this study can contribute based on securing stability, improving reliability, and continuous improvement of railroad communication facilities should be conducted in the operation of the entire railroad system.

Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine (스팀터빈의 공력성능 평가를 위한 공기 상사실험)

  • Lim, Byeung-Jun;Lee, Eun-Seok;Lee, Ik-Hyoung;Kim, Young-Sang;Kwon, Gee-Bum
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.73-79
    • /
    • 2003
  • The steam turbine efficiency is an important factor in power plant. Accurate evaluation of steam turbine performance is essential. However, it is not easy to evaluate the steam turbine performance due to its high temperature and high pressure circumstance. Therefore most steam turbine performance tests were conducted by air similarity test. This paper described a test program for air similarity test of steam turbine at Korea Aerospace Research Institute. A test facility has been designed and built to evaluate aerodynamic performance of turbines. The test facility consists of air supply system, single stage test section, power absorption system, instrumentation and auxiliary system. For evaluation of steam turbine performance, the test of single stage axial turbine air similarity performance was conducted and uncertainty analysis was performed.

  • PDF

Development of Competency and Behavioral Indicator of an Administrator in Long-term Care Facility (노인요양시설 관리자의 역량 및 행동지표 개발)

  • Kim, Ji-Soo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.14 no.4
    • /
    • pp.477-487
    • /
    • 2008
  • Purpose: The purpose of this study is to develop the competencies of the administrator and the behavioral indicators, and with those as the foundation it is to measure the importance and the performance. Method: On the basis of literature review, the researcher made a preliminary competency and the behavioral indicator for the administrator. Developed competency and behavioral indicator went through the content validity using CVI. Finally, 20 different competencies and 87 behavioral indicators of the administrators in long-term care facility helped measuring the importance of the present administrator's competency and the performance. Results: The competencies are Achievement Orientation, Initiative, Information Seeking, Interpersonal Understanding, Customer Service Orientation, Marketing, Influence, Organizational Awareness, Relationship Building, Staff Development, Assertiveness, Teamwork and Cooperation, Leadership, Analytical Thinking, Conceptual Thinking, Managerial Expertise, Self Control, Self Confidence, Flexibility and Organizational Commitment. For the contents, 87 behavioral indicators are included. The importance and the performance were confirmed by Importance Performance Analysis. The importance of each behavioral indicator in each field and the performance were confirmed with the mean and the standard deviation. Conclusion: The competencies and behavioral indicators of an administrator which were developed by this study are considered that they can be used as the effective guides in the practical field and can also be used as basic materials for developing educational program.

  • PDF

Performance Evaluation for Deteriorated Masonry of Military Facilities (조적조 노후 군시설의 성능평가기준)

  • Yang, Eun-Bum;Shin, Jong-Hyun;Lee, Chan-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.167-174
    • /
    • 2003
  • Military facilities with masonry have a great portion in the whole military facilities. But lots of them have been used for more than 20 years, the degree of deterioration of the facilities are serious. Futhermore, as insufficient budget for the facilities maintenance and poor maintenance, the performance of the aged masonry facilities have continually decreased. We suggest a structural performance assessment criteria for the military facility through literature review, interview with experts and questionnaire. The major assessment factors for the structural performance include the inclining and sinking degree of the facilities, durability of materials and resisting force of the structural members.

Development of Key Performance Indicators in Ammunition Demilitarization Facility Using the Balanced Score Card (균형성과표(BSC)를 활용한 탄약 비군사화 시설의 핵심성과지표 개발)

  • Bae, Young-Min;Han, Seung-Jo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.1
    • /
    • pp.17-25
    • /
    • 2021
  • Ammunition Demilitarization facility (ADF) should be set up the feasible goals and continue to operate, taking into account non-profit characteristics. However, due to the lack of performance measurement methods in ADF, which are essential to national policy at a significant cost each year, the reliability of the evaluation results can be insufficient. In this paper, the Balanced Score Card (BSC) method was applied that could be evaluated to reflect the financial and non-financial features. The relevant literature research and army regulations reflected the results of various interviews of the expert group. The extraction of success performance area in ADF was confirmed using the BSC method and the Decision Variable (DV) candidate was created to use regression for selecting the DV. Additionally, the key performance indicator was presented by verification the feasibility of content by conducting the survey of experts. The implications of this paper are as follows. First, the proposed BSC model was found to be suitable for practical use in ADF reflecting the non-profit characteristics. Second, accurate evaluation of ADF can contribute to long-term development of ADF. Finally, it can be applied to the management process of the other military sector, so it can be expected to play a role in providing basic data and spreading it to other areas.