• Title/Summary/Keyword: Performance Facility

Search Result 1,529, Processing Time 0.023 seconds

The DISNY facility for sub-cooled flow boiling performance analysis of CRUD deposited zirconium alloy cladding under pressurized water reactor condition: Design, construction, and operation

  • Ji Yong Kim;Yunju Lee;Ji Hyun Kim;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3164-3182
    • /
    • 2023
  • The CRUD on the fuel cladding under the pressurized water reactor (PWR) operating condition causes several issues. The CRUD can act as thermal resistance and increases the local cladding temperature which accelerate the corrosion process. The hideout of boron inside the CRUD results in axial offset anomaly and reduces the plant's shutdown margin. Recently, there are efforts to revise the acceptance criteria of emergency core cooling systems (ECCS), and additionally require the modeling of the thermal resistance effect of the CRUD during the performance analysis. There is an urgent need for the evaluation of the effect of the CRUD deposition on the cladding heat transfer under PWR operating conditions, but the experimental database is very limited. The experimental facility called DISNY was designed and constructed to analyze the CRUD-related multi-physical phenomena, and the performance analysis of the constructed DISNY facility was conducted. The thermal-hydraulic and water chemistry conditions to simulate the CRUD growth under PWR operating conditions were established. The design characteristics and feasibility of the DISNY facility were validated by the MARS-KS code analysis and separate performance tests. In the current study, detailed design features, design validation results, and future utilization plans of the proposed DISNY facility are presented.

Operating Performance Evaluation of Landfill Facility and Landfill Gas (LFG) Energy Facility (매립시설 및 매립가스 에너지화시설 운영현황 분석)

  • Kim, Jong-Hwan;Phae, Chae-Gun;Park, Joon-Seok
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.221-232
    • /
    • 2018
  • This research was conducted to evaluate the operational performance of landfill facility and landfill gas energy facility from the questionnaire survey. In order to evaluate overall operational performance, three types of weighting methods were applied to each technical, economical, and environmental item. There was no significant difference between an equal weighted method, a weighted method of 40% for technology, 30% for economy, and 30% for environment, and a weighted method of 30% for technology, 40% for economy, and 30% for environment. In technical performance, large and middle scales of landfill facilities showed higher scores of 14.8 ~ 19.7 and 14.3 ~ 19.0 than 9.8 ~ 13.0 of small scale one. In environmental performance, large, middle, and small scales of landfill facilities showed 21.3 ~ 23.7, 17.6 ~ 19.6, and 20.8 ~ 23.1 scores, respectively. However, in economical performance, there was significant difference between them with scale. Large and middle scales of landfill facilities showed higher scores of 22.0 ~ 29.3 and 20.5 ~ 27.3 than 6.0 ~ 8.0 of small scale one. As a result of evaluation for landfill gas energy facility, large scale facility showed 19.2 ~ 25.6 and 17.8 ~ 23.7 scores in technical performance and 23.1 ~ 25.7 and 21.3 ~ 23.7 scores in environmental performance, respectively. However, in economical performance evaluation, large scale of landfill gas energy facility showed relatively higher of 27.8 ~ 33.3 score than 18.8 ~ 25.1 of small scale one. From these results, it was shown that economy evaluation heavily effect on the operational performance of landfill facility and landfill gas energy facility compared to technology and environment evaluation.

Analysis of Performance Factors of Unmanned Aircraft System(UAS)-based Facility Management using Causal Loop Diagram (Causal Loop Diagram을 활용한 무인항공체계 기반 시설물 관리 영향인자 분석)

  • Kwon, Jin-Hyeok;Yu, Chae-Youn;Kim, Sungjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.85-86
    • /
    • 2022
  • Traditionally, the facility inspection was visually conducted by the managers, and consequently the result can be subjective because of different perspective and experience of them. To solve this problem, the studies on this topic has tried to integrate the UAS. However, it is still concerned to use in practice due to the lack of analysis of the performance factors affecting the UAS-based facility condition inspection. Hence, the purpose of this study is to identify the critical factors as well as their correlations by modeling causal loop diagram (CLD). A total of 20 variables were derived in four categorized groups, and the relationships were analyzed. Further study will develop a system dynamics (SD) model to simulate various scenarios based on stock-flow diagram through the defined relationships in this study.

  • PDF

A Study On the Development of Facility Management Performance Evaluation system by Analyzing Current FM Practices of Commercial Office Buildings (Commercial Office의 Facility Management(FM) 업무 현황 분석을 통한 성과 평가체계 구축 방안)

  • Yoon, Jong-Han;Cha, Hee-Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.89-90
    • /
    • 2016
  • Despite the rise of importance of Facility Management(FM), relatively little attention was paid to evaluate FM efficiency and drive for greater FM efficiency. The purpose of the present paper is to offer a quantitative analysis of 14 Key Success Factors(KSF) and 22 detailed maintenance practices in order to develop FM evaluation system. In addition, from survey with Owner/Property Manager group and Facility Manager group, the present paper measures both importance of detailed maintenance practices and performance satisfaction. It is expected that by using the result of this survey, this paper helps increase efficiency in FM. Moreover, It is expected that this paper will be used as base line data in developing FM practice evaluation system.

  • PDF

Development of Cryogenic Pump Test Facility (극저온 펌프 성능시험설비의 개발)

  • Kang, Jeong-Seek;Kim, Jin-Sun;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.4 s.25
    • /
    • pp.47-52
    • /
    • 2004
  • Cryogenic pump test facility (CPTF) is designed and developed in KARI. Hydraulic and cavitation performance of pump and inducer in cryogenic environment can be measured. Working fluid is liquid nitrogen and operating temperature is $-197^{\circ}C$. Run tank, catch tank of liquid nitrogen and their pressurizing tank has been built and remote tank pressure control system are installed. Maximum power of driving motor is 320 kW and its maximum speed is 32000rpm. Cryogenic fluids and lubricating systems are effectively separated that long test times are acquired. Therefore hydraulic and cavitation performance can be measured accurately and effectively. Pre-cooling test of the facility was successfully accomplished. This facility will contribute greatly to the development of turbopump for KSLV.

Evaluation of Performance Index for Optimization of Food Waste Treatment and Recovery Facility (음식물류폐기물 자원화시설 최적화를 위한 이행지표 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • This research was performed to evaluate the food waste recovery facility using optimization performance index. In 2014, the generated amount of food waste occupied approximately 27% in total municipal solid waste. The 97.2% of the food waste was recycled and the others were treated through landfill and incineration in the portion of 0.9% and 1.9%, respectively. In food waste recovery facilities of year 2014, the composting and feed facilities were 49.5% and 22.9%, respectively. The feed facility showed higher scores in all technological, environmental, and especially economical evaluations than those of composting facility. As results of overall optimization performance index, the feed facility has higher score of 61.5 than 52.7 of composting facility. It was demonstrated that the feed facility has the advantage, compared with the composting facility.

Development of A Model for Diagnosing Management Capabilities of Public Facility (공공시설물관리 역량 진단 모델 개발)

  • Sung, Yookyung;Yoo, Wi Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.6
    • /
    • pp.555-566
    • /
    • 2020
  • Recently, the aging of public facilities in Korea have accelerated, and the existing framework for facility management is shifting toward to facility asset management in terms of performance-based proactive control. Therefore, the operation of public facility involves both safety assurance from the deteriorated facilities and management capabilities for sustainable maintenance in the required valuation and level of service, such as valuation of facility assets, life-cycle management plans, financing, and so on. In this study, the Facility Asset Management Indicator(FAMI) has been developed for public facility asset management, and it provides the quantitative management grade, based on international standards, such as ISO 55000 series and International Infrastructure Management Manual(IIMM). The FMMI includes 10 key areas to apply a diagnosis model into management capabilities, 113 detailed elements, and 5 maturity grades. As the importance of public facility asset management is increasing constantly, this is expected to identify previously the strengths and weaknesses of public facility operating institutions. Eventually, they can obtain the effective ways to improve their own capabilities, minimize the public funds, establish the strategies for innovating the current management structures, and operate stably the facilities in the required performance.

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facility

  • Park, Byung-Kyu;Kim, Moo-Geun;Kim, Geun-Oh
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.17-26
    • /
    • 2001
  • Simulation was conducted using TRNSYS to evaluate the thermal performance of a facility. This facility has a condensing-type heat exchanger which is able to recover the latent energy for the purpose of reducing the heating energy in winter. The boiler and chiller are selected based on the annual peak loads and controlled to maintain the facility at the set temperature of 14~$17^\circ{C}$. Supplied energy by the boiler and recovered energy by the heat exchanger were calculated as a function of number of pass through heat exchanger, kind of fuel and hot water velocity. Simulation results show that about 20% of the total heating load can be recovered by the heat exchanger and the amount of latent heat is increasing with the number of pass. This means that the efficiency of the waste energy recovery system can be increased by using a condensing-type heat exchanger rather than a traditional sensible heat exchanger.

  • PDF

A Study on the Space Composition of the Educational Cultural Center for Students (학생교육문화회관의 공간구성에 관한 연구)

  • Jeong, Gwan-Yeong;Lim, Jang-Lyul;Kim, Yong-Hwan
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.12 no.5
    • /
    • pp.25-34
    • /
    • 2005
  • The Educational Cultural Center for Students is a new mixed-cultural space which made around 1997 for students' education of humanism and talent with the 7th revision of educational course. This Educational Cultural Center for Students is different to the existing one because the subject of the culture is students who make creation and performance by themselves while the former ones were for seeing, hearing and feeling things. There are seven Educational Cultural Center for Students all over the country and will be built more in the future. Comparing to the former Educational Cultural Centers for Students, functional rooms in the Educational Cultural Centers for Students are an outdoor performance room, a large performance room, a small performance room of performance facility, a gallery of display facility, a gymnasium, a swimming pool, a fitness room, a table-tennis room of physical facility, a library and a reading room of a book facility, and a group room, a computer room, a singing room, a billiard room, an art room, a musical room, a dancing room, a manner room, a playing room, a cultural lecture room and a seminar room of a interest-activity facility. The result of analyzing the usage frequency is that a performance room has the highest frequency and a display room, a musical room, a music appreciation room and a physical room follow the frequency order. But this frequency does not fit for all area. By place and social situations, the frequency and space organization may be changed.

Case Study on the Implementation of Facility AI Platform for Small and Medium Enterprises of Korean Root Industry (뿌리업종 중견중소기업의 설비 AI 플랫폼 구축에 관한 사례연구)

  • Lee, Byong Koo;Moon, Tae Soo
    • The Journal of Information Systems
    • /
    • v.32 no.3
    • /
    • pp.205-224
    • /
    • 2023
  • Purpose This study investigates the impact of organizational characteristics on organizational performance through case studies of smart factory implementation in the context of Korean small and medium Enterprises (SMEs). To achieve this goal, this study adopts the smart factory index of KOSMO (Korea Smart Manufacturing Office) established by Korean Ministry of SMEs and Startups. We visited 3 firms implemented smart factory projects. This study presents the results of field study in detail with evaluation criteria on how organizational competences like AI technology adoption and facility automation can be exploited to positively influence organizational performance through smart factory implementation. Design/methodology/approach There are not so many results of empirical studies related to smart factories in Korea. This is because organizational support and user involvement are required for facility AI platform service beyond factory automation after the start of the 4th Industrial Revolution. Korean government's KOSMO (Korean Smart Manufacturing Office) has developed and proposed a level measurement index for smart factory implementation. This study conducts case studies based on the level measurement method proposed by KOSMO in the process of conducting case studies of three companies belonging to the root and mechanic industries in Korea. Findings The findings indicate that organizational competences, such as facility AI platform adoption and user involvement, are antecedents to influence smart factory implementation, while smart factory implementation has significant relationship with organizational performance. This study provides a better understanding of the connection between organizational competences and organizational performance through smart factory case studies. This study suggests that SMEs should focus on enhancing their organizational competences for improving organizational performance through implementing smart factory projects.