• Title/Summary/Keyword: Performance Experiment and Evaluation

Search Result 1,138, Processing Time 0.033 seconds

Validity Analysis of Scale Model Experiment for Wetting Agent Performance Evaluation (침윤소화약제 성능평가를 위한 축소실험의 타당성 분석)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.14-19
    • /
    • 2014
  • A current standard exist only on the surface tension in the current domestic wetting agent technology standards, so it is difficult to the performance evaluation of the wetting agent through the standard. So this study presents the optimized performance evaluation methods by scale model experimental equipment in order to present techniques for performance evaluation of wetting agents. The purpose of this study is to investigate validity of experimental results of the self-designed scale model experiment equipment by a comparative analysis of experimental results of the NFPA 18 experiment and the experiment using the self-designed scale model experiment equipment. As a result of a comparative analysis of experimental results of the NFPA 18 experiment that evaluate only the permeation performance on the contton and the experiment using the self-designed scale model experiment equipment that evaluate the permeation performance and fire extinguishing performance on wood flour, the discrimination of the permeation performance was confirmed in both the NFPA 18 experiment and the self-designed scale model experiment equipment. And a result of self-designed experiment equipment have clear discriminatory more than NFPA 18 by internal temperature measurement using the thermocouples.

A Study on the Corrosion Properties of Reinforcing bar and Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by Exposure Experiment under the Coastal and Normal Atmosphere Environment (해양 및 일반대기환경의 폭로실험에 의한 철근콘크리트구조물 보수재료.공법의 성능평가 및 철근의 부식특성에 관한 연구)

  • Nam Jeong-Soo;Roh Kyung-Min;Shin Seung-Bong;Kim Young-Sun;kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.167-171
    • /
    • 2006
  • In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chlorideion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of corrosion of reinforcing bar are inner chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Accordingly, it is considered that fundamental data on the performance evaluation and quality control standards of repair material and method could be presented through continuous exposure test in the future.

  • PDF

Analysis of the Acoustic Evaluation Factors Depending on the in Performance Types Multi-purpose Halls (다목적홀의 공연종류에 따른 음향평가요인 분석)

  • Park, Hyeon-Ku;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.66-74
    • /
    • 2006
  • This study aimed to evaluate the room acoustical performances of multi-purpose halls, surveying the architectural features and analysing the acoustical characteristics by measurements. In addition, adjectives appropriate for the evaluation of the room acoustical performance in multi-purpose halls were determined through the method of questionnaire survey and subjective evaluation through psycho-acoustic experiment. The results from the experiment were analysed by the correlation analysis and the factor analysis, consequently useful adjectives for the evaluation of acoustical performances in multi-purpose halls were determined depending on the types of performance.

Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment (공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석)

  • Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.

Analysis and evaluation of sound reduction performance of drywall system (건식벽체 차음성능 분석 및 평가)

  • Baek, Seung-Kyung;Chang, Chun-Sang;Go, Jong-Cheol;Lee, Jong-In;Kim, Hyun-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.727-732
    • /
    • 2009
  • The objective of this study is to analyze and evaluate design factors relating to sound reduction performance in dry wall system. The main contents of this study are as follows. 1) Analysis and pre-evaluation of sound reduction performance of drywall system ; The sound reduction performance was pre-evaluated by INSUL simulation and these results of analyzing walls were analyzed by screening DOE(design of experiment) for selecting major factors that dominant influence the sound reduction performance. These main factors relating to sound reduction performance can be used for development of 1st grade sound reduction performance drywall system. 2) Design and evaluation of 1st grade sound reduction performance drywall system; The evaluation test of the sound reduction performance gave vaues higher than 1st grade (Rw+C=64). When campared with existing dry wall system, respectivelly, the new system shows performance higher than 8 dB.

  • PDF

Soft Real-time Capabilities and Communication Performance Evaluation in Qplus for Multimedia Streaming Service (멀티미디어 스트리밍 서비스에 대한 QPLUS의 연성 실시간 및 통신 성능 평가)

  • Lee, GowangLo;Bae, ByeongMin;Lee, InHan;Kim, MinJung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.301-304
    • /
    • 2013
  • In this paper, to improve the fast boot and soft real-time for the responsiveness in Qplus with relative evaluation rather than an absolute evaluation using validated to perform the services actually used. Qplus is included soft real-time, fast booting, and file system technology. There is a development board that mounted on an embedded Linux and Qplus. AV (Audio / Video) group communications is ported on the development board for soft real-time multimedia streaming services and to evaluate the performance of communication. We performed three major evaluation such as booting time measurement experiment, own performance measurement experiments for soft real-time measurement experiment, and performance measurement experiments for via the network communication performance evaluation. They are a practical Qplus performance evaluation and analysis.

  • PDF

Performance Evaluation for Coordinate Measuring Machine using Design of Experiments (실험계획법을 이용한 3차원 좌표 측정기의 성능 평가)

  • Lee, Seung-Pyo;Ha, Sung-Kyu
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.133-139
    • /
    • 2008
  • With the increasing demand for higher production quality and growing competition in the global market, coordinate measuring machine(CMM) has been widely used in industry to improve the efficiency and effectiveness of measurement. In this paper the performance evaluation of coordinate measuring machine is proposed using design of experiments. A factorial design is applied to carry out the performance test proposed by ISO 10360 with a length bar and to investigate CMM measurement errors associated to orientation and length in the work volume. The determination of the significance of effects in an experiment is made through the analysis of variance(ANOVA). The results show that the proposed method is suitable to analyze the factors which affect the CMM measurement performance.

Evaluation of Wheel Load Fatigue Performance of FRP-Concrete Composite Deck (FRP-콘크리트 합성 바닥판의 윤하중 피로 성능 평가)

  • Cho, Keun-Hee;Park, Sung-Yong;Cho, Jeong-Rae;Kim, Sung-Tae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.38-41
    • /
    • 2006
  • Wheel load fatigue experiment is carried out on a FRP-concrete composite deck. In FRP-concrete composite deck, FRP plays a role of a main tensile member as well as a permanent formwork and concrete plays a role of a main compressive member. Wheel load fatigue experiment, which shows more realistic behavior than pulsating fatigue experiment, is selected as a fatigue performance evaluation method. Until 1,000,000 cycles of loadings, load resistant performance is maintained without any loss, while residual deflection is increased.

  • PDF

Hydrodynamic Evaluation Method for Developing the Inflatable Kayak (인플래터블 카약 개발을 위한 유체역학적 성능평가 기법)

  • Ki, Jae-Seok;Hah, Chong-Ku;Jang, Ho-Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.627-634
    • /
    • 2012
  • This study includes results of basin test for hydrodynamic performance evaluation with a developed inflatable kayak. Inclining experiment and turning trial experiment of the developed inflatable kayak and an abroad product were carried out in the Ocean engineering Basin. Resistance test was carried out by using downscale model in the circulating water channel. Through method of following performance evaluation, advantage and disadvantage of the developed inflatable kayak were compared with those of the abroad product.

Validity Evaluation of Scale Model Experiments in Architectural Daylighting Performance (자연채광 성능평가에 있어서 축소모형실험 방법론의 유용성 검증에 관한 연구)

  • Kim, J.T.;Chung, Y.G.;Jeong, I.Y.;Hwang, M.K.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Daylighting is a powerful vehicle of architectural expression and provides buildings a living quality due to constantly changing properties in intensity and color. As an environmental system, daylighting should be subjected to the same level of rigorous analysis and review that any environmental system receives. For example, increasing cooling loads and causing visual displeasure are easily occurred owing to the excessive sunlight through windows. Therefore, daylighting performance attributes and physical characteristics must be described qualitatively and quantitatively in early design process. In various architectural daylighting performance evaluation methods, the scale model experiment can be applied due to it's simplicity and usefulness. So, this study aims to evaluate the validation of scale model experiments in architectural daylighting performance. For the purpose, two scale model experiments under clear sky are conducted. And, the validation of the experiments are evaluated by computer simulations.