• Title/Summary/Keyword: Performance Evaluation of Facility

Search Result 329, Processing Time 0.031 seconds

The Performance Evaluation of R407C and R410B in a Residential Window Air-Conditioner

  • Kim, Man-Hoe;Shin, Jeong-Seob;Kim, Kwon-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.148-157
    • /
    • 1998
  • This study presents test results of a residential window air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests has been carried out for the basic and liquid-suction heat exchange cycles in a psychometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-suction heat exchange cycle was also considered to improve the system performance. Test results were compared with those for the basic R22 system. The modified system with a liquid-suction heat exchanger increased cooling capacity and energy efficiency by up to 5%.

  • PDF

Regulatory Sentiment and Economic Performance

  • JUNGWOOK KIM;JINKYEONG KIM
    • KDI Journal of Economic Policy
    • /
    • v.45 no.1
    • /
    • pp.69-86
    • /
    • 2023
  • Regulatory sentiment refers to the market's subjective evaluation of regulatory reform and is one of the most widely adopted indicators to those charged with implementing and diagnosing regulatory policies. The use of regulatory sentiment in advanced analysis has become universal, albeit it is often limited due to difficulties in articulating consistent and objective quantitative indicators that can meticulously reflect market sentiment overall. Thus, despite ample effort by scholars to read the economic impact of regulatory sentiment in the real economy, causal links are difficult to spot. To fill this gap in the literature, this study analyzes a regulatory sentiment index and economic performance indicators through a text analysis approach and by inspecting diverse tones in media articles. Using different stages of tests, the paper identifies a causal relationship between regulatory sentiment and actual economic activities as measured by private consumption, facility investment, construction investment, gross domestic investment, and employment. Additionally, as a result of analyzing one-unit impulse of regulatory perception, the initial impact on economic growth and private investment was found to be negligible; this was followed by a positive (+) response, after which it converged to zero. Construction investment showed a positive (+) response initially, which then rapidly changed to a negative (-) response and then converged to zero. Gross domestic investment as the initial effect was negligible after showing a positive (+) reaction. Unfortunately, the facility investment outcome was found to be insignificant in the impulse response test. Nevertheless, it can be concluded that it is necessary and important to increase the sensitivity to regulations to promote the economic effectiveness of regulatory reforms. Thus, instead of dealing with policies with the vague goal of merely improving regulatory sentiment, using regulatory sentiment as an indicator of major policies could be an effective approach.

Large Capacity Passive Flow Control Vortex Valve (대용량 피동형 유량제어 와류 밸브)

  • Choi, N. H.;Chu, I.-C.;Chung, C. H.;Cho, B. H.;Song, C.-H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.635-640
    • /
    • 2004
  • The present paper provides the design specifications and working principle of flow controlling vortex valve which will be adopted in a Korean next generation reactor (APR1400). The vortex valve is installed inside the pressurized safety injection tank of APR1400, and it passively controls the water discharge flowrate from the tank. In the present study, the performance of the vortex valve have been evaluated throughout the repeated experiments in the full-scale test facility called VAPER(VAlve Performance Evaluation Rig). Based on the experimental results, it is confirmed that the currently developed vortex valve satisfies the major performance requirements of APR1400 plant design in view of the peak discharge flowrate, pressure loss coefficient, and total discharge duration time. To achieve the highest quality of the experimental results, a quality assurance program for vortex valve tests has been strictly applied.

  • PDF

A Study on the Performance Degradation Pattern of Caisson-type Quay Wall Port Facilities (케이슨식 안벽 항만시설의 성능저하패턴 연구)

  • Na, Yong Hyoun;Park, Mi Yeon;Jang, Shinwoo
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.146-153
    • /
    • 2022
  • Purpose: In the case of domestic port facilities, port structures that have been in use for a long time have many problems in terms of safety performance and functionality due to the enlargement of ships, increased frequency of use, and the effects of natural disasters due to climate change. A big data analysis method was studied to develop an approximate model that can predict the aging pattern of a port facility based on the maintenance history data of the port facility. Method: In this study, member-level maintenance history data for caisson-type quay walls were collected, defined as big data, and based on the data, a predictive approximation model was derived to estimate the aging pattern and deterioration of the facility at the project level. A state-based aging pattern prediction model generated through Gaussian process (GP) and linear interpolation (SLPT) techniques was proposed, and models suitable for big data utilization were compared and proposed through validation. Result: As a result of examining the suitability of the proposed method, the SLPT method has RMSE of 0.9215 and 0.0648, and the predictive model applied with the SLPT method is considered suitable. Conclusion: Through this study, it is expected that the study of predicting performance degradation of big data-based facilities will become an important system in decision-making regarding maintenance.

A Study on the Application of Design Indicators of the High School Facilities - Focused on High School in Gyeonggi-do - (고교시설 디자인 지표의 적용 분석 연구 - 경기도 고등학교를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.45-53
    • /
    • 2017
  • The purpose of this study is to provide the fundamental data to improve a school building through comparing and analyzing facilities of high schools located in Gyeonggi - do Province on the basis of the Design Indicator for the Korean Educational Buildings. Two types of high schools were examined for this study. Some of them are high schools selected by Korean Ministry of Education as a school equipped with superior facilities and the others are high schools equipped with general facilities. 8 items such as safety, comfort, the function of education, utilization, the public, eco-friendliness, technology performance, economical efficiency were examined by 5 point Likert scale. Findings showed that all facilities of both types of high schools received high ratings in terms of safety, utilization, and technology performance. However, the evaluation index on 'various used outdoor space' and 'public buildings harmonized with surroundings' of the education function of both types of high schools was low, which implies that the facility related to the education function needs to be improved. It infers that facilities are simplified and harmony with surroundings disappears when altering the design of the school building due to the convenience of building and the problem of the budget. Therefore, these need to be primarily controlled. Additionally, in high schools with general facilities, the evaluation index on 'aesthetic interior and exterior design of comfort', 'the responsive space to the demand for teaching and learning of the function of education', and eco-friendless were so low that these factors need to be considered when designing the school building.

Evaluation on HACCP prerequisite-program performance within general hospital foodservice operations (종합병원 급식소의 HACCP 선행요건 관리 수행도 평가)

  • Song, Yoon-Ji;Bae, Hyun-Joo
    • Journal of Nutrition and Health
    • /
    • v.49 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • Purpose: This study was conducted to examine prerequisite-program performance of the hospital foodservice operation and develop measures for improvement of prerequisite-program performance. Methods: Data were collected through surveys administered to 168 hospital dieticians in the Seoul, Incheon, Gyeonggi-do, Daegu, and North Gyeongsang areas. Out of total questionnaires, 65 questionnaires were usable and the response rate was 38.7%. Statistical analyses were performed using the SPSS program (ver 20.0) for ${\chi}^2-test$ and one-way ANOVA. Results: According to the result of the prerequisite-program evaluation, the percentage of 'appropriate', 'needs to be improved', and 'inappropriate' was 44.6%, 47.7%, and 7.7%, respectively. The score for the 'inappropriate' group was significantly lower than that of the 'appropriate' group or 'needs to be improved' group on the food safety management (p < 0.001), preparation facility management (p < 0.001), water management (p < 0.001), and storage transportation management (p < 0.05) parts. Holding rate of foodservice facility and equipments in the 'appropriate' group were significantly higher than in the others on convection oven (p < 0.01), air conditioner (p < 0.01), three-compartment sink (p < 0.01), hot-holding equipment (p < 0.01), cold-holding equipment (p < 0.05), exclusive thawing refrigerator (p < 0.05), and sterilizer for sanitary shoes (p < 0.05) items. Conclusion: To improve the quality of hospital foodservice, foodservice managers and HACCP specialists should develop and implement a prerequisite-program and a HACCP plan considering the characteristics of the hospital foodservice operation.

A Study on the Development of Design Indicator and User Participation Design for Green Remodeling of School Facilitiess (학교시설의 그린리모델링을 위한 디자인지표 개발 및 사용자참여설계 활용에 관한 연구)

  • Kim, Eun-Hee;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.3
    • /
    • pp.3-13
    • /
    • 2017
  • This study has developed a design indicator required to promote green remodeling in school facilities. And, implemented the green remodeling pilot test on the school facilities that are planning actual remodeling. This pilot test suggested user participation design methodology such as verification of the developed design indicator, design goal setting, evaluation and adjustment of design proposal. The Green Remodeling Design Indicators were classified into 3 large categories of architectural performance, usability, and design through analysis of cases related to 'green buildings' and 'remodeling'. We have developed nine middle categories such as architectural and structural performance, facility performance, environmentally-friendly, circulation, space, amenity, harmony with surroundings, form and symbolization. In addition, 42 detailed indicators were developed for each category, including general, functional, and special indicators. For the verification of this study, two green remodeling design workshops were conducted for Gwangju J elementary school. The first design workshop presented the importance of the design indicator and set the goal of the design plan of green remodeling for project. And, the second Workshop presented the evaluation of the satisfaction with the design and the direction of future adjustment for project. The design indicator developed in this study can be utilized as a design indicator of design quality management and decision system for the school green remodeling in the future. In addition, by accumulating information on the Green Remodeling Project, it is necessary to spread green remodeling and construct a sustainable building environment.

A Study on Human Error Assesment in Gas Industies (가스산업시설에서 인적 오류 평가 방법에 관한 연구)

  • Park Myung Seop;Kim Sung Bin;Ko Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.2 s.10
    • /
    • pp.52-57
    • /
    • 2000
  • This paper suggests the evaluation sheet to ensure the objective and detailed information based on a classification table of PIF (Performance Influencing Factor). And this paper shows the results of HEP(Human Error Probability), using a quantitative method with the evaluated data as a result of estimating the likelihood of . human errors in the gas industry facility together with the evaluation sheet. Finally, these results are programmed to be operated in personal computer so that field workers an apply it in easy and convenient manner. The results of this study offer two key benefits; sharing reliable information on human errors with the Data Base and establishing a strategy to reduce human errors as well as to improve working proficiency.

  • PDF

A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse (냉동냉장창고 침기방지장치의 성능평가에 관한 연구)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.

A study on the improvement for installation guide of soundproofing facilities in construction site (공사장 방음시설 설치기준 개선방안에 관한 연구)

  • Park, Young-Min;Kim, Kyoung-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Noise and vibration occurs during construction intermittently, but with the most arise complaints. There is a need to efficiently manage the construction noise and vibration problems because in case a residential facility that requires calmness around the construction site adversely affects the living conditions of nearby residents. The ministry of environment has mandating the installation of soundproofing facilities for the management of construction noise. In order to enforce a particular construction, the mandatory install with soundproofing facilities before the start of construction, and after construction. However, Installation guide of soundproofing facilities for construction sites were not considered affected areas by noise and there is no provision of performance evaluation for soundproofing facilities. In this study, investigated the status and problems of the installation guide for soundproofing facilities in construction sites, we propose an efficient installation guide of soundproofing facilities for the reduction construction noise.